← Product Code [MAX](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MAX) · K254017

# SWINGO-3D Lumbar Cage System (K254017)

_Implanet · MAX · Feb 26, 2026 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MAX/K254017

## Device Facts

- **Applicant:** Implanet
- **Product Code:** [MAX](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MAX.md)
- **Decision Date:** Feb 26, 2026
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3080
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Intended Use

The SWINGO-3D Lumbar Cage System is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the lumbar spine, at one or two contiguous levels, from L2 to S1 whose condition requires use of interbody fusion combined with supplemental fixation. These DDD patients may also have up to Grade 1 Spondylolisthesis or retrolisthesis at the involved levels. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. Patients should have had six months of non-operative treatment prior to surgery. The SWINGO-3D Lumbar Cage System is intended to be used with autograft and/or allogenic bone graft comprised of cancellous and/ or corticocancellous bone graft when the subject device is used as an adjunct to fusion. When used for these indications, the SWINGO-3D Cage System is intended for use with supplemental fixation systems cleared for use in the lumbar spine.

## Device Story

Additively manufactured titanium alloy lumbar interbody fusion cages (PLIF, TLIF, LLIF models); designed for stabilization and bone fusion promotion in lumbar spine surgery. Hollow geometry allows packing with autograft or allogenic bone graft. Implanted by surgeons during interbody fusion procedures; requires supplemental fixation systems. Provides structural support and correction between lumbar vertebrae. Benefits patients by facilitating spinal fusion in degenerative disc disease cases.

## Clinical Evidence

Bench testing only. Performance data (static/dynamic axial compression, compression shear per ASTM F2077-14; subsidence per ASTM F2267-04) was leveraged from the predicate device, as the subject device introduces no new worst-case conditions.

## Technological Characteristics

Additively manufactured titanium alloy (ASTM F3001) cages. Hollow geometry for bone graft packing. Provided sterile via gamma irradiation. Used with stainless steel (ASTM F899) instruments.

## Regulatory Identification

An intervertebral body fusion device is an implanted single or multiple component spinal device made from a variety of materials, including titanium and polymers. The device is inserted into the intervertebral body space of the cervical or lumbosacral spine, and is intended for intervertebral body fusion.

## Special Controls

*Classification.* (1) Class II (special controls) for intervertebral body fusion devices that contain bone grafting material. The special control is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intervertebral Body Fusion Device.” See § 888.1(e) for the availability of this guidance document.(2) Class III (premarket approval) for intervertebral body fusion devices that include any therapeutic biologic (e.g., bone morphogenic protein). Intervertebral body fusion devices that contain any therapeutic biologic require premarket approval.
(c)
*Date premarket approval application (PMA) or notice of product development protocol (PDP) is required.* Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.

## Predicate Devices

- Shanghai Sanyou Metal Additive Manufacturing Interbody Fusion Cages ([K230872](/device/K230872.md))
- Shanghai Sanyou PEEK Cage System ([K163422](/device/K163422.md))
- Shanghai Sanyou KEYSTONE PEEK Cage System ([K211689](/device/K211689.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

FDA U.S. FOOD &amp; DRUG ADMINISTRATION

February 26, 2026

Implanet
% Jen McBride
Regulatory Consultant
MRC Global, LLC
9160 Hwy 64, Suite 12
P.O. Box 330
Lakeland, Tennessee 38002

Re: K254017
Trade/Device Name: SWINGO-3D Lumbar Cage System
Regulation Number: 21 CFR 888.3080
Regulation Name: Intervertebral Body Fusion Device
Regulatory Class: Class II
Product Code: MAX
Dated: December 12, 2025
Received: December 15, 2025

Dear Jen McBride:

We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

U.S. Food &amp; Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov

{1}

K254017 - Jen McBride
Page 2

Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).

Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13484 clause 8.3 (Nonconforming product), and ISO 13485 clause 8.5 (Corrective and preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and 21 CFR 820.70) and document changes and approvals in the Medical Device File (21 CFR 820.181).

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.

All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-

{2}

K254017 - Jen McBride
Page 3

assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

Brent Showalter -S

Brent Showalter, Ph.D.
Assistant Director
DHT6B: Division of Spinal Devices
OHT6: Office of Orthopedic Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health

Enclosure

{3}

FORM FDA 3881 (8/23)
Page 1 of 1
PSC Publishing Services (301) 443-6740
EF

|  DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below.  |
| --- | --- |
|  510(k) Number (if known) K254017  |   |
|  Device Name SWINGO-3D Lumbar Cage System  |   |
|  Indications for Use (Describe) The SWINGO-3D Lumbar Cage System is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the lumbar spine, at one or two contiguous levels, from L2 to S1 whose condition requires use of interbody fusion combined with supplemental fixation. These DDD patients may also have up to Grade 1 Spondylolisthesis or retrolisthesis at the involved levels. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies. Patients should have had six months of non-operative treatment prior to surgery. The SWINGO-3D Lumbar Cage System is intended to be used with autograft and/or allogenic bone graft comprised of cancellous and/ or corticocancellous bone graft when the subject device is used as an adjunct to fusion. When used for these indications, the SWINGO-3D Cage System is intended for use with supplemental fixation systems cleared for use in the lumbar spine.  |   |
|  Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C)  |   |
|  CONTINUE ON A SEPARATE PAGE IF NEEDED.  |   |
|  This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*  |   |
|  The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov  |   |
|  "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."  |   |

{4}

K254017

510(k) Summary
SWINGO-3D Lumbar Cage System
February 17, 2026

Company: Implanet
Technopole Bordeaux Montesquieu
Allee Francois Magendie
Martillac Nouvelle-Aquitaine, FR 33650

Primary Contact: Jen McBride – Regulatory Consultant
MRC Global
9160 Hwy 64, Suite 12
PO Box 330
Lakeland, TN 38002
Email: jen.mcbride@AskMRCGlobal.com

Company/Secondary Contact: Régis Le Couëdic
Vice President - CTO
Implanet
Phone: +33 557 995 660
reglementaire@implanet.com

Trade Name: SWINGO-3D Lumbar Cage System
Common Name: Intervertebral Fusion Device With Bone Graft, Lumbar
Classification: Class II
Regulation: 21 CFR 888.3080
Panel: Orthopedic
Product Code: MAX

Device Description:
The SWINGO-3D Lumbar Cage System consists of three different models of additively manufactured lumbar interbody fusion devices—SWINGO-P-3D (PLIF), SWINGO-T-3D (TLIF), and SWINGO-L-3D (LLIF)—that are intended for stabilization use and to promote bone fusion during the normal healing process following surgical correction of disorders of the spine. These devices consist of additively manufactured titanium alloy (per ASTM F3001) cages of various heights and footprints, which can be inserted between two lumbar to give support and correction during interbody fusion surgeries. The hollow geometry of the implants allows them to be packed with autograft and/or allogenic bone graft material. The subject additively manufactured implants are provided sterile via gamma irradiation.

Page 1 of 3

{5}

K254017

The subject devices are modifications to the nearly-identical devices cleared by Shanghai Sanyou in the predicate submission (K230872). Shanghai Sanyou and Implanet have entered into an agreement in which Implanet will be the legal manufacturer of the subject devices and Shanghai Sanyou will be the contract manufacturer. Under the terms of this agreement, Implanet will maintain the quality system and handle all complaints related to the devices in this submission.

Previously cleared (K163422 and K211689) associated device specific and universal instruments are available to facilitate the implantation of interbody devices. All instruments are manufactured from instrument-grade stainless steel that conforms to ASTM F899. No new instruments are being added.

## Indications for Use:

The SWINGO-3D Lumbar Cage System is indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the lumbar spine, at one or two contiguous levels, from L2 to S1 whose condition requires use of interbody fusion combined with supplemental fixation.

These DDD patients may also have up to Grade 1 Spondylolisthesis or retrolisthesis at the involved levels. DDD is defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies.

Patients should have had six months of non-operative treatment prior to surgery.

The SWINGO-3D Lumbar Cage System is intended to be used with autograft and/or allogenic bone graft comprised of cancellous and/ or corticocancellous bone graft when the subject device is used as an adjunct to fusion. When used for these indications, the SWINGO-3D Cage System is intended for use with supplemental fixation systems cleared for use in the lumbar spine.

## Substantial Equivalence:

The subject SWINGO-3D Lumbar Cage System is substantially equivalent to the following predicate devices:

### Primary Predicate:

- Shanghai Sanyou Metal Additive Manufacturing Interbody Fusion Cages – K230872

### Additional Predicate Devices:

- Shanghai Sanyou PEEK Cage System – K163422
- Shanghai Sanyou KEYSTONE PEEK Cage System – K211689

There are insignificant differences between the subject SWINGO-3D Lumbar Cage System and the predicate. The Indications for Use for predicate devices are all inclusive of the subject device. The materials and manufacturing for the subject device are identical to those of the predicate. There are slight differences in the geometry of the subject and predicate devices, but no new worst case is introduced. The subject device is provided sterile, identical to the predicate device. Thus, it can be concluded that the subject does not raise new questions about safety and effectiveness.

Page 2 of 3

{6}

K254017

## Performance Testing:

Bench performance testing including static and dynamic axial compression and static and dynamic compression shear per ASTM F2077-14. Subsidence testing was also performed per ASTM F2267-04.

All testing was performed on the predicate device. However, the subject devices do not introduce any new worst case and is thus substantially equivalent to the predicate. Therefore, all previously performed testing is applicable to the subject devices and no additional performance testing is needed.

## Conclusion:

Based on the performance analysis and the comparison to the predicate devices, the subject device is determined to be substantially equivalent to the predicate devices.

Page 3 of 3

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MAX/K254017](https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/MAX/K254017)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
