K971824 · Biomet, Inc. · LPH · Dec 4, 1997 · Orthopedic
Device Facts
Record ID
K971824
Device Name
REACH FEMORAL HIP COMPONENT
Applicant
Biomet, Inc.
Product Code
LPH · Orthopedic
Decision Date
Dec 4, 1997
Decision
SN
Submission Type
Traditional
Regulation
21 CFR 888.3358
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Reach Femoral Component is intended for use in reconstruction of the hip joint due to damage caused by trauma or degenerative disease and in cases where a previous hip replacement component failed. The device is intended for cemented application for general use and non-cemented application in skeletally mature individuals undergoing primary surgery for rehabilitating hip joints damaged as a result of non-inflammatory degenerative joint disease or any of its composite diagnosis. This device is a single use implant.
Device Story
Reach Femoral Hip Component is a forged titanium femoral stem designed for hip joint reconstruction. Device features proximal bi-planar taper for stress shielding reduction and rotational stability; duckbill porous-coated collar for load transfer; and distal cylindrical geometry with anterior bow for anatomic fit. Stem is fully porous-coated to facilitate bony ingrowth and seal against debris. Distal tip features polished finish to prevent pedestal effect. Implant is used by orthopedic surgeons in clinical settings for cemented or non-cemented hip arthroplasty. Device articulates with commercially available acetabular components. Benefits include improved rotational stability, preservation of calcar bone, and potential for biological fixation in proximal bone deficiency cases.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Forged titanium femoral stem; bi-planar proximal taper; duckbill porous-coated collar; distal cylindrical geometry with anterior bow; circumferential closed-pore porous coating; polished distal tip. Designed for cemented or non-cemented application. Compatible with Type I taper trunnion modular heads.
Indications for Use
Indicated for skeletally mature individuals undergoing primary hip reconstruction due to trauma, degenerative joint disease, or revision of failed previous hip components. Contraindications include non-skeletally mature patients.
Regulatory Classification
Identification
A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.
{0}------------------------------------------------
K971824
DEC - 4 1997
## SUMMARY OF SAFETY AND EFFECTIVENESS
Sponsor:
Biomet, Inc. Airport Industrial Park Warsaw, Indiana 46580
Reach Femoral Hip Component Device:
Classification Name: Hip joint metal/polymer/metal semi-constrained porous coated uncemented prosthesis (888.3358) and hip joint metal/ceramic/polymer semi-constrained porous coated cemented prosthesis (888.3350).
Intended Use: The Reach Femoral Component is intended for use in reconstruction of the hip joint due to damage caused by trauma or degenerative disease and in cases where a previous hip replacement component failed.
The device is intended for cemented application for general use and non-cemented application in skeletally mature individuals undergoing primary surgery for rehabilitating hip joints damaged as a result of non-inflammatory degenerative joint disease or any of its composite diagnosis.
This device is a single use implant.
Device Description: The device is composed of a metallic femoral stem (forged titanium) which is designed to articulate with a commercially available acetabular component.
The Reach stem geometry is designed for proximal, as well as, distal stability and gradual officading into the bone along the canal. The proximal 100mm of each stern incorporates a bi-planar taper to encourage proximal officading, thus reducing stress shielding. This broad proximal geometry fills a greater portion of the metaphysis, thus providing improved rotational stability. In a cemented application, the increased proximal stress transfer of titanium helps preserve the calcar bone and maintain the integrity of the proximal cement mantle.
The stem has a duckbill porous coated collar which is incorporated to provide component stability and stress transfer. The underside of the collar is porous coated to help ensure collar-calcar contact and stress distribution. This helps to provide rotational stablity and load transfer.
Distally, the stem is cylindrical after 100mm with an anterior bow for left and right specific applications. The distal anterior bow more closely matches the anatomic femur to provide rotational stability. This cylindrical design will also enhance implant stability by providing a potential area of biological fixation in situations of proximal bone deficiencies. The lower modulus of elasticity of a titanium stem will also produce less distal stress officading and is less likely to fracture the cement mantle.
{1}------------------------------------------------
The Reach temoral stems will be fully coated to provide maximum proximal and distal fixation through bony ingrowth. This circumferential closed-pore porous coating potentially seals the femur from debris migration. Porous coating on the underside of the collar along with extended proximal to distal porous coating, provide areas of potential tissue ingrowth in crucial regions of cortical bone. The roughened surface of the porous coating will also enhance the hip stem / cement bonding, thus improving the chances of long-term success. The distal tip of the stern is a sisal buff or polished finish, to prevent distal offloading and fixation of the tip (otherwise known as the "pedestal effect").
Potential Risks: The potential risks associated with this device are the same as with any joint replacement device. These include, but are not limited to:
| Reaction to bone cement | Bone fracture |
|-----------------------------|-----------------------------|
| Fracture of the components | Hematoma |
| Cardiovascular disorders | Blood vessel damage |
| Implant loosening/migration | Nerve damage |
| Soft tissue imbalance | Excessive wear |
| Deformity of the joint | Infection |
| Tissue growth failure | Dislocation |
| Delayed wound healing | Metal sensitivity |
| Fracture of the cement | Breakdown of porous surface |
Substantial Equivalence: The Reach Femoral Hip Component is substantially equivalent to almost all femoral devices on the market in overall design and intended function. Predicate devices include:
000004 4
AML® (Depuy, Warsaw, IN) PMA# P820024000
్రా
| The Solution System ® (Depuy, Warsaw, IN) | -510(k)# K933942 |
|--------------------------------------------|------------------|
| | -510(k)# K941942 |
| | -510(k)# K953703 |
Integral® Total Hip System (Biomet, Inc., Warsaw, IN) -510(k) K921255
{2}------------------------------------------------
Image /page/2/Picture/2 description: The image shows the logo for the Department of Health & Human Services (HHS) of the United States of America. The logo features a stylized eagle with three stripes representing the department's mission. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC - 4 1997
Deborah M. Matarazzo, R.N., B.S.N. Clinical Research Specialist Biomet, Inc. P.O. Box 587 46581-0587 Warsaw, Indiana
K971824 Re : Reach Femoral Hip Component Trade Name: Requlatory Class: II Product Codes: LZO and LPH Dated: September 5, 1997 Received: September 8, 1997
Dear Ms. Matarazzo:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act and the following limitation that the package insert must reflect that the Zirconia Ceramic Femoral Heads are to be used only with forged Ti6A14V alloy hip stems with the Type I taper trunnions.
The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. ਜੋ substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory
{3}------------------------------------------------
Page 2 - Deborah M. Matarazzo, R.N., B.S.N.
In addition, FDA may publish further announcements action. concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal Laws or Regulations.
Under Section 522(a) of the act, manufacturers of certain types of devices identified by the Act or designated by FDA are required to conduct postmarket surveillance studies. FDA has identified under Section 522(a) (1) (C) the device cleared for marketing by this letter as requiring postmarket surveillance. The rationale for this decision is contained in the enclosed attachment.
Within thirty (30) days of first introduction or delivery for introduction of this device into interstate commerce you are required to submit to FDA certification of the date of introduction into interstate commerce, a detailed protocol which describes the postmarket surveillance study, and a detailed profile of the study's principal investigator that clearly establishes the qualifications and experience of the individual to conduct the proposed study. For your information, general guidance on preparing a protocol for a postmarket surveillance study is attached.
Submit five (5) copies to:
Center for Devices and Radiological Health Postmarket Surveillance Studies Document Center Room 3083 (HFZ-544) 1350 Piccard Drive Rockville, Maryland 20850
Within sixty (60) days of receipt of your protocol, FDA will either approve or disapprove it and notify you of the Agency's action in writing. You should not begin your postmarket surveillance study of this device until the protocol has been Data generated under an unapproved protocol may not approved. satisfy your obligation under section 522. Please note that you must continue to collect and report data needed to maintain compliance with Medical Device Reporting regulations (21 CFR 803).
Failure to certify accurately the date of initial introduction of your device into interstate commerce, to submit timely an acceptable protocol, or to undertake and complete an FDA approved postmarket surveillance study consistent with the protocol will be considered violations of section 522. In accordance with the Medical Device Amendments of 1992, failure
{4}------------------------------------------------
Page 3 - Deborah M. Matarazzo, R.N., B.S.N.
of a manufacturer to meet its obligations under section 522 is a prohibited act under section 301 (q) (1) (C) of the Act (21 U.S.C. 331 (q) (1) (C). Further, under section 502 (t) (3) of the act (21 U.S.C. 352(t)(3)), a device is misbranded if there is a failure or refusal to comply with any requirement under section 522 of the act. Violations of sections 301 or 502 may lead to regulatory actions including seizure of your product, injunction, prosecution, or civil money penalties.
If you have questions concerning postmarket surveillance study requirements, contact the Postmarket Surveillance Studies Branch at (301) 594-0639.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification immediately. An FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to
premarket notification" (21 CFR 807.97). Other general Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.qov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Witten, Ph.D.
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
K971824
DEC - 4 1997
## SUMMARY OF SAFETY AND EFFECTIVENESS
Sponsor:
Biomet, Inc. Airport Industrial Park Warsaw, Indiana 46580
Reach Femoral Hip Component Device:
Classification Name: Hip joint metal/polymer/metal semi-constrained porous coated uncemented prosthesis (888.3358) and hip joint metal/ceramic/polymer semi-constrained porous coated cemented prosthesis (888.3350).
Intended Use: The Reach Femoral Component is intended for use in reconstruction of the hip joint due to damage caused by trauma or degenerative disease and in cases where a previous hip replacement component failed.
The device is intended for cemented application for general use and non-cemented application in skeletally mature individuals undergoing primary surgery for rehabilitating hip joints damaged as a result of non-inflammatory degenerative joint disease or any of its composite diagnosis.
This device is a single use implant.
Device Description: The device is composed of a metallic femoral stem (forged titanium) which is designed to articulate with a commercially available acetabular component.
The Reach stem geometry is designed for proximal, as well as, distal stability and gradual officading into the bone along the canal. The proximal 100mm of each stern incorporates a bi-planar taper to encourage proximal officading, thus reducing stress shielding. This broad proximal geometry fills a greater portion of the metaphysis, thus providing improved rotational stability. In a cemented application, the increased proximal stress transfer of titanium helps preserve the calcar bone and maintain the integrity of the proximal cement mantle.
The stem has a duckbill porous coated collar which is incorporated to provide component stability and stress transfer. The underside of the collar is porous coated to help ensure collar-calcar contact and stress distribution. This helps to provide rotational stablity and load transfer.
Distally, the stem is cylindrical after 100mm with an anterior bow for left and right specific applications. The distal anterior bow more closely matches the anatomic femur to provide rotational stability. This cylindrical design will also enhance implant stability by providing a potential area of biological fixation in situations of proximal bone deficiencies. The lower modulus of elasticity of a titanium stem will also produce less distal stress officading and is less likely to fracture the cement mantle.
{6}------------------------------------------------
The Reach temoral stems will be fully coated to provide maximum proximal and distal fixation through bony ingrowth. This circumferential closed-pore porous coating potentially seals the femur from debris migration. Porous coating on the underside of the collar along with extended proximal to distal porous coating, provide areas of potential tissue ingrowth in crucial regions of cortical bone. The roughened surface of the porous coating will also enhance the hip stem / cement bonding, thus improving the chances of long-term success. The distal tip of the stern is a sisal buff or polished finish, to prevent distal offloading and fixation of the tip (otherwise known as the "pedestal effect").
Potential Risks: The potential risks associated with this device are the same as with any joint replacement device. These include, but are not limited to:
| Reaction to bone cement | Bone fracture |
|-----------------------------|-----------------------------|
| Fracture of the components | Hematoma |
| Cardiovascular disorders | Blood vessel damage |
| Implant loosening/migration | Nerve damage |
| Soft tissue imbalance | Excessive wear |
| Deformity of the joint | Infection |
| Tissue growth failure | Dislocation |
| Delayed wound healing | Metal sensitivity |
| Fracture of the cement | Breakdown of porous surface |
Substantial Equivalence: The Reach Femoral Hip Component is substantially equivalent to almost all femoral devices on the market in overall design and intended function. Predicate devices include:
000004 4
AML® (Depuy, Warsaw, IN) PMA# P820024000
్రా
| The Solution System® (Depuy, Warsaw, IN) | -510(k)# K933942 |
|------------------------------------------|------------------|
| | -510(k)# K941942 |
| | -510(k)# K953703 |
Integral® Total Hip System (Biomet, Inc., Warsaw, IN) -510(k) K921255
{7}------------------------------------------------
Image /page/7/Picture/2 description: The image shows the logo for the Department of Health & Human Services (HHS) of the United States of America. The logo features a stylized eagle with three stripes representing the department's mission. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC - 4 1997
Deborah M. Matarazzo, R.N., B.S.N. Clinical Research Specialist Biomet, Inc. P.O. Box 587 46581-0587 Warsaw, Indiana
K971824 Re : Reach Femoral Hip Component Trade Name: Requlatory Class: II Product Codes: LZO and LPH Dated: September 5, 1997 Received: September 8, 1997
Dear Ms. Matarazzo:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act and the following limitation that the package insert must reflect that the Zirconia Ceramic Femoral Heads are to be used only with forged Ti6A14V alloy hip stems with the Type I taper trunnions.
The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. ਜੋ substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory
{8}------------------------------------------------
Page 2 - Deborah M. Matarazzo, R.N., B.S.N.
In addition, FDA may publish further announcements action. concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal Laws or Regulations.
Under Section 522(a) of the act, manufacturers of certain types of devices identified by the Act or designated by FDA are required to conduct postmarket surveillance studies. FDA has identified under Section 522(a) (1) (C) the device cleared for marketing by this letter as requiring postmarket surveillance. The rationale for this decision is contained in the enclosed attachment.
Within thirty (30) days of first introduction or delivery for introduction of this device into interstate commerce you are required to submit to FDA certification of the date of introduction into interstate commerce, a detailed protocol which describes the postmarket surveillance study, and a detailed profile of the study's principal investigator that clearly establishes the qualifications and experience of the individual to conduct the proposed study. For your information, general guidance on preparing a protocol for a postmarket surveillance study is attached.
Submit five (5) copies to:
Center for Devices and Radiological Health Postmarket Surveillance Studies Document Center Room 3083 (HFZ-544) 1350 Piccard Drive Rockville, Maryland 20850
Within sixty (60) days of receipt of your protocol, FDA will either approve or disapprove it and notify you of the Agency's action in writing. You should not begin your postmarket surveillance study of this device until the protocol has been Data generated under an unapproved protocol may not approved. satisfy your obligation under section 522. Please note that you must continue to collect and report data needed to maintain compliance with Medical Device Reporting regulations (21 CFR 803).
Failure to certify accurately the date of initial introduction of your device into interstate commerce, to submit timely an acceptable protocol, or to undertake and complete an FDA approved postmarket surveillance study consistent with the protocol will be considered violations of section 522. In accordance with the Medical Device Amendments of 1992, failure
{9}------------------------------------------------
Page 3 - Deborah M. Matarazzo, R.N., B.S.N.
of a manufacturer to meet its obligations under section 522 is a prohibited act under section 301 (q) (1) (C) of the Act (21 U.S.C. 331 (q) (1) (C). Further, under section 502 (t) (3) of the act (21 U.S.C. 352(t)(3)), a device is misbranded if there is a failure or refusal to comply with any requirement under section 522 of the act. Violations of sections 301 or 502 may lead to regulatory actions including seizure of your product, injunction, prosecution, or civil money penalties.
If you have questions concerning postmarket surveillance study requirements, contact the Postmarket Surveillance Studies Branch at (301) 594-0639.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification immediately. An FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to
premarket notification" (21 CFR 807.97). Other general Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.qov/cdrh/dsmamain.html".
Sincerely yours,
Celia M. Whitten, Ph.D.
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{10}------------------------------------------------
Page 1 of _1
510(k) Number (if known): K971824
Device Name: Reach Femoral Component
Indications For Use:
The Reach Femoral Component is intended for use in reconstruction of the hip joint due to damage caused by trauma or degenerative disease and in cases where previous hip replacement component failed. The device is intended for cemented application for general use and non-cemented application in skeletally mature approduction artinary surgery for rehabilitating hip joints damaged as
individuals undergoing primary surgery for rehabilitat ing hip internet of its comments of comments of Modular Head component or Metallic Modular Head component with appropriate matching Type I Taper.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
OR
Over-The-Counter Use
(Optional Format 1-2-96)
(Divisio Division of General Resto 510(k) Number
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.