K073479 · Life Spine · KWQ · Jan 9, 2008 · Orthopedic
Device Facts
Record ID
K073479
Device Name
KINETIC-SL ANTERIOR CERVICAL PLATE SYSTEM
Applicant
Life Spine
Product Code
KWQ · Orthopedic
Decision Date
Jan 9, 2008
Decision
SESE
Submission Type
Special
Regulation
21 CFR 888.3060
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The KINETIC®-SL Anterior Cervical Plate System is intended for anterior interbody screw fixation of the cervical spine. This system is indicated for use in temporary stabilization of the anterior spine from C2 to T1 during the development of a cervical spinal fusion in patients with: (1) Degenerative disc disease, DDD (as defined by neck pain of discogenic origin with degeneration of disc confirmed by patient history and radiographic studies); (2) Spondylolisthesis (3) Trauma (including fractures or dislocations); (4) Spinal cord stenosis; (5) Deformity or curvatures (i.e. kyphosis, lordosis and/or scoliosis); (6) Tumors: (7) Pseudarthrosis; (8) Failed previous fusions. Nota Bene: This device system is intended for anterior cervical intervertebral body fusions only. WARNING: This device is not approved for screw attachment to the posterior elements (pedicles) of the cervical, thoracic, or lumbar spine.
Device Story
KINETIC®-SL Anterior Cervical Plate System provides temporary anterior spinal stabilization; facilitates fusion from C2 to T1. System comprises titanium alloy bone plates and screws in various sizes to accommodate patient anatomy. Used by surgeons in clinical settings for patients with degenerative disc disease, trauma, deformity, or other cervical pathologies. Device is supplied non-sterile; requires sterilization before use. Provides mechanical fixation to support bone healing; does not involve electronic inputs, software, or automated processing.
Clinical Evidence
No clinical data. Bench testing only.
Technological Characteristics
Implant grade titanium alloy 6Al-4V ELI per ASTM F-136. Mechanical fixation system consisting of plates and screws. Non-sterile, requires sterilization. No software or energy source.
Indications for Use
Indicated for temporary stabilization of the anterior cervical spine (C2-T1) during spinal fusion in patients with degenerative disc disease, spondylolisthesis, trauma (fractures/dislocations), spinal cord stenosis, deformity (kyphosis, lordosis, scoliosis), tumors, pseudarthrosis, or failed previous fusions. Contraindicated for posterior element (pedicle) attachment.
Regulatory Classification
Identification
A spinal intervertebral body fixation orthosis is a device intended to be implanted made of titanium. It consists of various vertebral plates that are punched into each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to a series of vertebrae to correct “sway back,” scoliosis (lateral curvature of the spine), or other conditions.
Life Spine Anterior Cervical Plate System (K07028)
Submission Summary (Full Text)
{0}------------------------------------------------
K073479
Page 1 of 2
JAN - 9 2008
#### 510(k) Summary
### 510(k) Summary - KINETIC®-SL Anterior Cervical Plate System
| Submitted By: | Life Spine<br>2401 W. Hassell Road, Suite 1535<br>Hoffman Estates, IL 60169<br>Telephone: 847-884-6117<br>Fax: 847-884-6118 |
|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------|
| 510(k) Contact: | Rebecca Brooks<br>Life Spine<br>2401 W. Hassell Road, Suite 1535<br>Hoffman Estates, IL 60169<br>Telephone: 847-884-6117<br>Fax: 847-884-6118 |
| Date Prepared: | December 10, 2007 |
| Trade Name: | KINETIC®-SL Anterior Cervical Plate System |
| Common Name: | Spinal Fixation System |
| Classification: | Spinal intervertebral body fixation orthosis<br>21 CFR 888.3060<br>Class II |
| Device Product Code: | KWQ |
| Predicate Device: | KINETIC® Anterior Cervical Plate K062643<br>Life Spine Anterior Cervical Plate System K07028 |
# Device Description:
The KINETIC® -SL Anterior Cervical Plate System consists of various sizes of anterior cervical bone plates and screws. Components are available in a variety of sizes to fit patient anatomy. All components are manufactured from implant grade titanium alloy 6A1-4V ELI per ASTM F-136. KINETIC®-SL Anterior Cervical Plate System components will be supplied clean and "NON-STERILE".
{1}------------------------------------------------
K073479
Page 2 of 2
#### Intended Use of the Device:
The KINETIC®-SL Anterior Cervical Plate System is intended for anterior interbody screw fixation of the cervical spine. This system is indicated for use in temporary stabilization of the anterior spine from C2 to T1 during the development of a cervical spinal fusion in patients with: (1) Degenerative disc disease, DDD (as defined by neck pain of discogenic origin with degeneration of disc confirmed by patient history and radiographic studies);
(2) Spondylolisthesis
(3) Trauma (including fractures or dislocations);
(4) Spinal cord stenosis;
(5) Deformity or curvatures (i.e. kyphosis, lordosis and/or scoliosis);
(6) Tumors:
(7) Pseudarthrosis;
(8) Failed previous fusions.
Nota Bene: This device system is intended for anterior cervical intervertebral body fusions only.
WARNING: This device is not approved for screw attachment to the posterior elements (pedicles) of the cervical, thoracic, or lumbar spine,
#### Substantial Equivalence:
The KINETIC® SL Anterior Cervical Plate System was shown to be substantially equivalent to previously cleared devices in indications for use, design, function, and materials used.
{2}------------------------------------------------
Public Health Service
Image /page/2/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with its wings spread, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. The eagle is black, and the text is also black. The logo is simple and recognizable.
JAN - 9 2008
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Life Spine % Ms. Rebecca Brooks 2401 W. Hassell Road Suite 1535 Hoffman Estates, IL 60169
Re: K073479
Trade/Device Name: KINETIC®-SL Anterior Cervical Plate System Regulation Number: 21 CFR 888.3060 Regulation Name: Spinal intervertebral body fixation orthosis Regulatory Class: II Product Code: KWQ Dated: December 10, 2007 Received: December 11, 2007
Dear Ms. Brooks:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
Page 2 - Ms. Rebecca Brooks
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Mark M. Wilkerson
Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the logo for Life Spine. The words "Life Spine" are written in a bold, sans-serif font. A curved line is present below the word "Spine". The logo is simple and modern.
Page 1 of 1
## Indications for Use
510(k) number (if known): _ KO73479
Device Name: KINETIC®-SL Anterior Cervical Plate System
The KINETIC® SL Anterior Cervical Plate System is intended for anterior interbody screw fixation of the cervical spine. This system is indicated for use in temporary stabilization of the anterior spine from C2 to T1 during the development of a cervical spinal fusion in patients with (1) degenerative disc disease, DDD (as defined by neck pain of discogenic origin with degeneration of disc confirmed by patient history and radiographic studies), (2) spondylolisthesis, (3) trauma (including fractures or dislocations), (4) spinal cord stenosis, (5) deformity or curvatures (i.e. kyphosis, lordosis and/or scoliosis), (6) turnors, (7) pseudarthrosis, (8) failed previous fusions.
Nota Bene: This device system is intended for anterior cervical interverterbral body fusions only.
WARNING: This device is not approved for screw attachment to the posterior elements (pedicles) of the cervical, thoracic, or lumbar spine.
Prescription Use _x_ (Part 21 CFR 801 Subpart D) And/Or
Over-the-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Barbara Buehm
Division of General, Restorative, and Neurological Devices
510(k) Number K07 3179