ARGOMEDICAL BIPOLAR SYSTEM

K981451 · Stelkast Company · KWL · Aug 21, 1998 · Orthopedic

Device Facts

Record IDK981451
Device NameARGOMEDICAL BIPOLAR SYSTEM
ApplicantStelkast Company
Product CodeKWL · Orthopedic
Decision DateAug 21, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3360
Device ClassClass 2
AttributesTherapeutic

Intended Use

1. Fractures of the proximal femur. 2. Non-unions of proximal femoral neck fractures. 3. Aseptic necrosis of the femoral head. 4. Osteo-rheumatoid and post-traumatic arthritis of the hip with minimal distortion of the acetabulum. 5. Salvage of failed total hip arthroplasty.

Device Story

The ARGOMEDICAL Bipolar Hip System is a prosthetic hip implant used in orthopedic surgery. It replaces the femoral head to restore joint function in patients with degenerative or traumatic hip conditions. The device is implanted by an orthopedic surgeon in a clinical/hospital setting. It functions as a mechanical replacement for the natural femoral head, articulating within the acetabulum to facilitate hip movement and weight-bearing. The system is intended to alleviate pain and improve mobility for patients suffering from specific hip pathologies.

Clinical Evidence

No clinical data provided; substantial equivalence based on design and intended use.

Technological Characteristics

Bipolar hip prosthesis; mechanical implant; materials and specifications not detailed in provided text.

Indications for Use

Indicated for patients requiring hip arthroplasty due to proximal femoral fractures, non-unions of femoral neck fractures, aseptic necrosis of the femoral head, osteo-rheumatoid or post-traumatic arthritis with minimal acetabular distortion, or salvage of failed total hip arthroplasty.

Regulatory Classification

Identification

A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted to replace a portion of the hip joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum. This generic type of device includes designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone ingrowth.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles a stylized human figure. AUG 2 1 1998 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Mr. Donald A. Stevens President StelKast Company 800 Vinial Street, Suite B-210 Pittsburgh, Pennsylvania 15212 K981451 Re: ARGOMEDICAL Biopolar Hip System Regulatory Class: II Product Code: KWL Dated: July 21, 1998 Received: July 22, 1998 Dear Mr. Stevens: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, qood manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. ದ್ substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP requlation may result in requlatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {1}------------------------------------------------ ## Page 2 - Mr. Donald A. Stevens This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Russell W. Ayres Celia M. Witten, Ph. D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## 981451 510(K) Number (if known): Device Name: StelKast Company - ARGOMEDICAL Bipolar System Indications For Use: - 1. Fractures of the proximal femur. - 2. Non-unions of proximal femoral neck fractures. - 3. Aseptic necrosis of the femoral head. - 4. Osteo-rheumatoid and post-traumatic arthritis of the hip with minimal distortion of the acetabulum. - 5. Salvage of failed total hip arthroplasty. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Thurber Lyman Brewer (Division Sinn. Division of General Restor 510(k) Number Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________ (Optional Format 1-2-96)
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...