← Product Code [JWH](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/JWH) · K993111

# ASCENT KNEE SYSTEM (K993111)

_Biomet Manufacturing, Inc. · JWH · Oct 5, 1999 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/JWH/K993111

## Device Facts

- **Applicant:** Biomet Manufacturing, Inc.
- **Product Code:** [JWH](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/JWH.md)
- **Decision Date:** Oct 5, 1999
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 888.3560
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Intended Use

The indications for use for Biomet knee joint replacement prostheses include: 1) painful and disabled knee joint resulting from osteoarthritis, theumatoid arthritis, traumatic arthritis where one or more compartments are involved; 2) Correction of varus, valgus, or posttraumatic deformity; and 3) Corrections or revision of unsuccessful osteotomy, arhtrodesis, or failure of previous joint replacement procedure. This device is for use with bone cement

## Device Story

Ascent Closed Box Posterior Stabilized Femoral Component is a stemmable knee prosthesis for patients with extensive ligament damage. Device features five sizes in right/left configurations; femoral articulation matches Performance Posterior Stabilized Knee (K936274). Design allows reconstruction of natural femur dimensions and kinematics; includes Interlok finish for cemented applications. Compatible with constrained or PS tibial bearings; supports independent posterior and distal augments for bone loss correction; compatible with previously cleared Performance stems and locking screws. Used by orthopedic surgeons in clinical settings for total knee arthroplasty to restore joint function and alleviate pain.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

Metal/polymer semiconstrained cemented prosthesis. Features Interlok finish for cemented fixation. Compatible with Performance stems and locking screws. Design allows for independent posterior and distal augments. No software or electronic components.

## Regulatory Identification

A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).

## Predicate Devices

- Performance Posterior Stabilized Knee ([K936274](/device/K936274.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

## SUMMARY OF SAFETY AND EFFECTIVENESS

Sponsor: Biomet, Inc. Airport Industrial Park P.O. Box 587 Warsaw, IN 46581-0587

Contact Person: Dalene Hufziger Binkley (219) 372-1612

Trade Name: Ascent Knee System

Classification Name: Knee joint patello-femorotibial polymer/metal/polymer semiconstrained cemented prosthesis (CFR 888.3560).

Device Description: The Ascent Closed Box Posterior Stabilized Femoral Component is a stemmable knee component designed for use in cases where extensive ligament damage has occurred. This design is based upon the features of the currently marketed Performance Closed Box Knee Components with certain modifications.

There are five sizes available in both right and left configurations. The femoral articulation is the same as the Performance Posterior Stabilized Knee (K936274). The anatomic component design allows the surgeon to reconstruct the anatomic dimensions and kinematics of the natural femur. The femoral component has an Interlok finish for use in cemented applications.

The Ascent Closed Box PS Femoral Component can be used with either a constrained or PS tibial bearing. The femoral component also has independent posterior and distal augments to correct bone loss deficiencies and can still be used with previously cleared Performance stems and locking screw.

Potential Risks: The potential risks associated with this device are the same as with any joint replacement disease. These include, but not limited to:

Reaction to bone cement Deformity of the joint Cardiovascular diseases Fracture of the cement Implant loosening/Migration Tissue growth failure

Blood vessel damage Soft tissue imbalance Delayed wound healing Metal sensitivity Fracture of the components Nerve damage

Bone fracture Infection Hematoma Dislocation Excessive wear

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or a bird in flight, composed of three curved lines.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

OCT 5 1999

Ms. Mary L. Verstynen Manager of Clinical Affairs Biomet, Inc. P.O. Box 587 Warsaw, Indiana 46581-0587

Re: K993111

Trade Name: Ascent Knee System Regulatory Class: II Product Code: JWH Dated: September 16, 1999 Received: September 17, 1999

Dear Ms. Verstynen:

We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (OS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

{2}------------------------------------------------

## Page 2 -- Ms. Mary L. Verstynen

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits vour device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597, or at its Internet address "http://www.fda.gov/cdrh/dsmamain.html".

Sincerely yours,

Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

Page **_ of _**

## 510 (k) NUMBER (if KNOWN): __ K 9 3 | | (

DEVICE NAME: Ascent Closed Box Posterior Stabilized Femoral

INDICATIONS FOR USE:

The indications for use for Biomet knee joint replacement prostheses include: 1) painful and disabled knee joint resulting from osteoarthritis, theumatoid arthritis, traumatic arthritis where one or more compartments are involved; 2) Correction of varus, valgus, or posttraumatic deformity; and 3) Corrections or revision of unsuccessful osteotomy, arhtrodesis, or failure of previous joint replacement procedure.

This device is for use with bone cement

## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.)

| Concurrence of CDRH, Office of Device Evaluation (ODE) |  |        |                                                                                        |
|--------------------------------------------------------|--|--------|----------------------------------------------------------------------------------------|
| Prescription Use<br>(Per 21 CFR 801.109)               |  | OR     | Over-The-Counter-Use<br>(Optional Format 1-2-96)                                       |
|                                                        |  | 000007 | (Division Sign-Off)<br>Division of General Restorative Devices / 9931<br>510(k) Number |

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/JWH/K993111](https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/JWH/K993111)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com