DALL-MILES STAINLESS STEEL BEADED CABLE
Device Facts
| Record ID | K961569 |
|---|---|
| Device Name | DALL-MILES STAINLESS STEEL BEADED CABLE |
| Applicant | Howmedica Corp. |
| Product Code | JDQ · Orthopedic |
| Decision Date | Jun 24, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3010 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Dall-Miles Beaded Cable is intended to be used for spinal wiring, sternotomy applications, cerclage procedures, and trauma surgery of the shoulder, elbow, knee, hip, or ankle. In addition, these cables may be used for supplementary fixation when used with bone plates and screws and for the stabilization of bone graft material.
Device Story
Stainless steel cable with electron-beam-melted bead on one end; modification of existing cable design. Used with one-sided tensioner in space-constrained surgical sites where two-sided tensioners are unsuitable. Operates as bone fixation cerclage; provides mechanical stabilization for bone segments or grafts. Used by surgeons in OR settings for orthopedic and trauma procedures. Output is physical fixation of bone/graft; assists in fracture reduction and stabilization; facilitates healing by maintaining bone alignment.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Stainless steel cable; electron-beam-melted bead termination. Mechanical fixation device. No software or energy source.
Indications for Use
Indicated for patients requiring spinal wiring, sternotomy, cerclage procedures, trauma surgery of the shoulder, elbow, knee, hip, or ankle, supplementary fixation with bone plates/screws, or stabilization of bone graft material.
Regulatory Classification
Identification
A bone fixation cerclage is a device intended to be implanted that is made of alloys, such as cobalt-chromium-molybdenum, and that consists of a metallic ribbon or flat sheet or a wire. The device is wrapped around the shaft of a long bone, anchored to the bone with wire or screws, and used in the fixation of fractures.
Predicate Devices
- Dall-Miles Trochanter Cable Grip System (K844068)
- Dall-Miles Trochanter Cable Grip System (K900926)
- Dall-Miles Suture/Beaded Cable (K953818)
- Ries Cable System (K875156)
- Control Cable System (K934557)
Related Devices
- K971741 — DALL-MILES HOMOGENEOUS STAINLESS STEEL CABLE AND BEADED CABLE · Howmedica Corp. · Jul 16, 1997
- K031162 — SMITH & NEPHEW ORTHOPAEDIC CABLING SYSTEM · Smith & Nephew, Inc. · May 1, 2003
- K102834 — ISO-ELASTIC CERCLAGE SYSTEM (1MM AND 2MM CABLE DIAMETER) · Kinamed, Incorporated · Jan 12, 2011
- K133354 — PERI-PROSTHETIC CABLE SYSTEM · Biomet, Inc. · Jan 27, 2014
- K151888 — Frontier Medical Devices In-line Orthopedic Cable Cerclage System · Frontier Medical Devices, Inc. · Oct 30, 2015