← Product Code [HWC](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC) · K033749

# TITANIUM CANNULATED INTERFERENCE SCREW (K033749)

_Advanced Biomaterials · HWC · Feb 23, 2004 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC/K033749

## Device Facts

- **Applicant:** Advanced Biomaterials
- **Product Code:** [HWC](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC.md)
- **Decision Date:** Feb 23, 2004
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3040
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Intended Use

To provide interference fixation of soft tissue graft and bone-tendon-bone patellar graft during cruciate ligament repair through arthroscopy or arthrotomy.

## Device Story

Titanium cannulated interference screw used for fixation of soft tissue and bone-tendon-bone grafts in cruciate ligament repair. Device features tapered, smooth threaded design; available in lengths 20-50 mm and diameters 7-12 mm to accommodate patient/graft morphology. Used by surgeons during arthroscopic or arthrotomic procedures. Provides mechanical interference fixation to secure grafts within bone tunnels.

## Clinical Evidence

No clinical data provided; substantial equivalence based on design and intended use similarities.

## Technological Characteristics

Titanium material; cannulated, tapered, smooth threaded design; dimensions 20-50 mm length, 7-12 mm diameter; mechanical bone fixation fastener.

## Regulatory Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- Alaron Technologies, LLC ([K010595](/device/K010595.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

## FEB 2 3 2004

## 510(k) SUMMARY FOR THE TITANIUM CANNULATED INTERFERENCE SCREW

ADVANCED BIOMATERIALS S.A.S (ABS) Company: Address: 265. Route de la Baronne, 06640 Saint-Jeannet, France Phone: +33 4 92 12 04 74 Fax: +33 4 92 12 04 75

510k #:K033749
page 1 of 1

Mr. Patrick Janin Contact:

Date of submission: November 28 2003

Name of device:

Titanium cannulated interference screw

Common or usual name:

Titanium interference screw

Classification:

Smooth or threaded bone fixation fastener: HWC, 888.3040

Predicate device:

K010595: Alaron Technologies, LLC.

Device intended use, description and substantial equivalence:

The titanium cannulated interference screw is tapered and has a smooth threaded design. which provides interference fixation of soft tissue grafts and bone-tendon-bone patellar grafts during cruciate ligament repair through arthroscopy or arthrotomy.

The screw comes in lengths between 20 and 50 mm and diameters between 7mm and 12mm, resulting in a screw adapted to the morphology of the graft and patient.

The titanium cannulated interference screw and the predicate device have the same overall design. In addition, the small differences in design do not affect the use, safety and effectiveness, between the device and the predicate device.

Based on these similarities and equivalences we believe our titanium cannulated interference screw and the Alaron interference screw K010595 are substantially equivalent for the interference fixation of soft tissue and Bone Tendon Bone graft in cruciate ligament reconstruction through arthroscopy or arthrotomy.

{1}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three tail feathers, enclosed in a circle. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the perimeter of the circle.

Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

FEB 2 3 2004

Mr. Patrick Janin Advanced Biomaterials 265 Route De La Baronne St. Jeannet, 06640 France

Re: K033749

Trade/Device Name: Titanium cannulated interference screw Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth or threaded metallic bone fixation fastener Regulatory Class: II Product Code: HWC Dated: November 28, 2003 Received: December 1, 2003

Dear Mr. Janin:

We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed four be determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for use stated in the encreativent of the enactment date of the Medical Device Amendments, or to conninered pror to May 20, 2017 11:11 accordance with the provisions of the Federal Food, Drug, de nees may nave toen i vent do not require approval of a premarket approval application (PMA). and Cosmetic . For (110) that the device, subject to the general controls provisions of the Act. The r va may more provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it rr your de ree to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean r hat FDA has made a dctermination that your device complics with other requirements of the Act that + 127 Heral statutes and regulations administered by other Federal agencies. You must or any I ederal statuted and seguirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set Orth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{2}------------------------------------------------

Page 2 - Mr. Patrick Janin

This letter will allow you to begin marketing your device as described in your Section 510(k) This letter witi anow you to begin mailsong of substantial equivalence of your device to a legally premaired predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please If you ucate specific advice for your as (301) 594-4659. Also, please note the regulation entitled, Colliact the Office of Comphane as (Se Fri Station" (21CFR Part 807.97). You may obtain Misoranding of Citrerence to premaxionsibilities under the Act from the Division of Small other general informational and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

Mark A. Melleksen

Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

510 K Number: k023749

Page 1 of 1

Device name: Titanium cannulated interference screw

INDICATIONS FOR USE:

To provide interference fixation of soft tissue graft and bone-tendon-bone patellar graft during cruciate ligament repair through arthroscopy or arthrotomy.

Mark N Millerson

Division of General, Restorative, and Neurole leal Devices

**510(k) Number** K033744

(Please do not write below this Line-Continue on another page if needed.)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription Use (Per 21 CFR 801.109)

OR

Over-The-Counter-Use (Optional Format 1)

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC/K033749](https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC/K033749)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
