BIOMET PHOENIX ANKLE NAIL SYSTEM

K081243 · Biomet Trauma · HSB · Jun 27, 2008 · Orthopedic

Device Facts

Record IDK081243
Device NameBIOMET PHOENIX ANKLE NAIL SYSTEM
ApplicantBiomet Trauma
Product CodeHSB · Orthopedic
Decision DateJun 27, 2008
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3020
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Biomet Phoenix™ Ankle Nail System is indicated for tibiotalocalcaneal arthrodesis (fusion). Specific indications include: 1. Avascular necrosis of the talus 2. Failed total ankle arthroplasty 3. Trauma (malunited tibial pilon fracture) 4. Severe deformity or instability as a result of talipes equinovarus, cerebral vascular accident, paralysis or other neuromuscular disease 5. Revision ankle arthrodesis 6. Neuroarthropathy 7. Rheumatoid arthritis 8. Osteoarthritis 9. Pseudoarthrosis

Device Story

Biomet Phoenix™ Ankle Nail System is an intramedullary fixation rod used for tibiotalocalcaneal arthrodesis. Device provides structural support for bone fusion in patients with severe ankle pathology or trauma. System consists of metallic nail and associated hardware implanted by orthopedic surgeons in clinical/surgical settings. Device stabilizes ankle joint to facilitate fusion; benefits include correction of deformity, restoration of stability, and pain relief associated with arthritic or necrotic conditions. No electronic or software components.

Clinical Evidence

No clinical data provided. Substantial equivalence based on engineering bench testing.

Technological Characteristics

Intramedullary fixation rod. Materials: Ti-6Al-4V and UHMWPE. Mechanical fixation device; no energy source, connectivity, or software.

Indications for Use

Indicated for tibiotalocalcaneal arthrodesis in patients with avascular necrosis of the talus, failed total ankle arthroplasty, trauma (malunited tibial pilon fracture), severe deformity/instability (talipes equinovarus, CVA, paralysis, neuromuscular disease), revision ankle arthrodesis, neuroarthropathy, rheumatoid arthritis, osteoarthritis, or pseudoarthrosis.

Regulatory Classification

Identification

An intramedullary fixation rod is a device intended to be implanted that consists of a rod made of alloys such as cobalt-chromium-molybdenum and stainless steel. It is inserted into the medullary (bone marrow) canal of long bones for the fixation of fractures.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K081243 pg 1 of 2 ## 510(k) Summary Biomet Phoenix™ Ankle Nail System | Preparation Date: | June 25, 2008 | |----------------------|-------------------------------------------------------------------------------------------------------------| | Applicant/Sponsor: | Biomet Trauma (aka EBI; names may be used interchangeably)<br>100 Interpace Parkway<br>Parsippany, NJ 07054 | | Contact Person: | Debra L. Bing | | Proprietary Name: | Biomet Phoenix™ Ankle Nail System | | Common Name: | Intramedullary fixation rod | | Classification Name: | Rod, Fixation, Intramedullary and Accessories (21 CFR 888.3020) | ## Legally Marketed Devices To Which Substantial Equivalence Is Claimed: | Acid Etched Lag Screws | K070955 | Biomet Trauma | |----------------------------|---------|-------------------------| | Tibial Locking Nail System | K063570 | Biomet Trauma | | Ankle Arthrodesis Nail | K021786 | Biomet, Inc. | | UltiMax Ankle Fusion Rod | K991790 | Encore Orthopedics, Inc | #### Device Description: The Biomet Phoenix™ Nail System is an intramedullary nail system comprised of Ti-6Al-4V and UHMWPE. #### Indications for Use: The Biomet Phoenix™ Ankle Nail System is indicated for tibiotalocalcaneal arthrodesis (fusion). Specific indications include: - 1. Avascular necrosis of the talus - 2. Failed total ankle arthroplasty - 3. Trauma (malunited tibial pilon fracture) - 4. Severe deformity or instability as a result of talipes equinovarus, cerebral vascular accident, paralysis or other neuromuscular disease - 5. Revision ankle arthrodesis - 6. Neuroarthropathy - 7. Rheumatoid arthritis - 8. Osteoarthritis - 9. Pseudoarthrosis {1}------------------------------------------------ KOS1243 pg a.f2 #### Summary of Technologies: The technological characteristics (materials, design, sizing) of the Biomet Phoenix™ Nail System are similar or identical to the predicate devices. Non-Clinical Testing: Engineering analyses comparing the Biomet Phoenix™ Nail System to a predicate device were conducted to determine substantial equivalence. The results indicated that the Biomet Phoenix™ Nail System was functional within its intended use. Clinical Testing: None provided as a basis for substantial equivalence. All trademarks are property of Biomet, Inc. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with its wings spread, symbolizing protection and care. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUN 2 7 2008 Biomet Manufacturing Corp. % Ms. Susan Alexander Regulatory Affairs Specialist P.O. Box 587 Warsaw, Indiana 46581-0587 Re: K081243 Trade/Device Name: Biomet Phoenix Ankle Nail System Regulation Number: 21 CFR 888.3020 Regulation Name: Intramedullary fixation rod Regulatory Class: II Product Code: HSB Dated: April 29, 2008 Received: May 1, 2008 Dear Ms. Alexander: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ ## Page 2 - Ms. Susan Alexander This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at toll-free number (800) 638-2041 or (240) 276-3150 or the Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincercly yours, Mark N. Milkeron Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Indications for Use 510(k) Number (if known):_K0812 43 Device Name: _______________________________________________________________ The Biomet Phoenix™ Ankle Nail System is indicated for tibiotalocalcaneal arthrodesis (fusion). Specific indications include: - 1. Avascular necrosis of the talus - 2. Failed total ankle arthroplasty - 3. Trauma (malunited tibial pilon fracture) - 4. Severe deformity or instability as a result of talipes equinovarus, cerebral vascular accident, paralysis or other neuromuscular disease - 5. Revision ankle arthrodesis - 6. Neuroarthropathy - 7. Rheumatoid arthritis - 8. Osteoarthritis - 9. Pseudoarthrosis Prescription Use __ AES (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1 (Division Sign-Off) Division of General, Restorative, and Neurological Devices 510(k) Number
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...