Last synced on 2 December 2022 at 11:04 pm

Lens, Contact, Orthokeratology, Overnight

Page Type
Product Code
Definition
Temporary reduction of myopia or refractive error.
Regulation Medical Specialty
Ophthalmic
Review Panel
Ophthalmic
Submission Type
PMA
Device Classification
Class 3
Regulation Number
886.5916
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 886.5916 Rigid gas permeable contact lens

§ 886.5916 Rigid gas permeable contact lens.

(a) Identification. A rigid gas permeable contact lens is a device intended to be worn directly against the cornea of the eye to correct vision conditions. The device is made of various materials, such as cellulose acetate butyrate, polyacrylate-silicone, or silicone elastomers, whose main polymer molecules generally do not absorb or attract water.

(b) Classification. (1) Class II if the device is intended for daily wear only.

(2) Class III if the device is intended for extended wear.

(c) Date PMA or notice of completion of a PDP is required. As of May 28, 1976, an approval under section 515 of the act is required before a device described in paragraph (b)(2) of this section may be commercially distributed. See § 886.3.

[52 FR 33355, Sept. 2, 1987, as amended at 59 FR 10284, Mar. 4, 1994]

Lens, Contact, Orthokeratology, Overnight

Page Type
Product Code
Definition
Temporary reduction of myopia or refractive error.
Regulation Medical Specialty
Ophthalmic
Review Panel
Ophthalmic
Submission Type
PMA
Device Classification
Class 3
Regulation Number
886.5916
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 886.5916 Rigid gas permeable contact lens

§ 886.5916 Rigid gas permeable contact lens.

(a) Identification. A rigid gas permeable contact lens is a device intended to be worn directly against the cornea of the eye to correct vision conditions. The device is made of various materials, such as cellulose acetate butyrate, polyacrylate-silicone, or silicone elastomers, whose main polymer molecules generally do not absorb or attract water.

(b) Classification. (1) Class II if the device is intended for daily wear only.

(2) Class III if the device is intended for extended wear.

(c) Date PMA or notice of completion of a PDP is required. As of May 28, 1976, an approval under section 515 of the act is required before a device described in paragraph (b)(2) of this section may be commercially distributed. See § 886.3.

[52 FR 33355, Sept. 2, 1987, as amended at 59 FR 10284, Mar. 4, 1994]