PHACOILLUMINATOR - FIBEROPTIC SLEEVE

K964018 · Michael Reynard, M.D. · HQC · Feb 26, 1997 · Ophthalmic

Device Facts

Record IDK964018
Device NamePHACOILLUMINATOR - FIBEROPTIC SLEEVE
ApplicantMichael Reynard, M.D.
Product CodeHQC · Ophthalmic
Decision DateFeb 26, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 886.4670
Device ClassClass 2

Indications for Use

Provide illumination at surgical site.

Device Story

Clear silicone sleeve; fits over phacofragmentation handpiece; transmits light from internal fiber optic channels to surgical site. Used in ophthalmic surgery by surgeons. Enhances visualization of surgical field during phacoemulsification; facilitates surgical precision.

Clinical Evidence

Bench testing only.

Technological Characteristics

Clear silicone material; sleeve form factor; passive light transmission via fiber optic coupling; non-powered; sterile.

Indications for Use

Indicated for use during ophthalmic surgery to provide illumination at the surgical site.

Regulatory Classification

Identification

A phacofragmentation system is an AC-powered device with a fragmenting needle intended for use in cataract surgery to disrupt a cataract with ultrasound and extract the cataract.

Predicate Devices

Submission Summary (Full Text)

{1} K964018 # CONFIDENTIAL AND PROPRIETARY INFORMATION Page Three 510(k) Summary per section 807.92(c) Submitter Name: Michael Reynard, M.D. Address: 1301 - 20th Street #260, Santa Monica, CA 90404 Telephone: 310-453-0551 FAX: 310-315-0133 Contact Person: Michael Reynard, M.D. Date of Summary: 9/30/1996 Name of Device: Accessory Illuminating Infusion Sleeve Tradename of Device: Phacoilluminator™ Equivalence: The subject device is a predicate silicone infusion sleeve without opaque or tint additives. Description of Device: Clear silicone sleeve that transmits light originating from fiber optic channels contained in the phacofragmentation handpiece. Intended Use of Device: Provide illumination at surgical site. Comparison with predicate devices: Construction material is identical with currently manufactured silicone infusion sleeve except that opaque additives are omitted to allow for light transmission.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...