MML · Weights, Eyelid, External

Ophthalmic · 21 CFR 886.5700 · Class 2

Overview

Product CodeMML
Device NameWeights, Eyelid, External
Regulation21 CFR 886.5700
Device ClassClass 2
Review PanelOphthalmic

Identification

An eyelid weight is a prescription device made of gold, tantalum, platinum, iridium, or surgical grade stainless steel that is rectangular in shape and contoured to the shape of the eye. The device is intended for the gravity assisted treatment of lagophthalmos (incomplete eyelid closure).(1) The external eyelid weight is adhered to the outer skin of the upper eyelid. (2) The implantable eyelid weight is implanted into the upper eyelid.

Classification Rationale

(1) Class II (special controls) for the external eyelid weight. The external eyelid weight is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 886.9. The special controls for the external eyelid weight are:(i) Testing demonstrating the biocompatibility of the device; and (ii) Labeling must include the following information: (A) Specific instructions regarding the proper placement, sizing, and removal of the device; and (B) A warning stating that the patient should be instructed to remove the device prior to entering a magnetic resonance environment. (2) Class II (special controls) for the implantable eyelid weight. The special controls for the implantable eyelid weight are: (i) Testing demonstrating the biocompatibility of the device; (ii) Testing demonstrating the sterility and shelf life of the device; (iii) Nonclinical testing evaluating the compatibility of the device in a magnetic resonance environment. (iv) Patient labeling to convey information regarding the safety and compatibility of the device in a magnetic resonance environment, the conditions under which a patient with the device can be safely scanned, and a mechanism for a healthcare provider to obtain detailed information about magnetic resonance safety and compatibility if needed.

Special Controls

*Classification.* (1) Class II (special controls) for the external eyelid weight. The external eyelid weight is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 886.9. The special controls for the external eyelid weight are:(i) Testing demonstrating the biocompatibility of the device; and (ii) Labeling must include the following information: (A) Specific instructions regarding the proper placement, sizing, and removal of the device; and (B) A warning stating that the patient should be instructed to remove the device prior to entering a magnetic resonance environment. (2) Class II (special controls) for the implantable eyelid weight. The special controls for the implantable eyelid weight are: (i) Testing demonstrating the biocompatibility of the device; (ii) Testing demonstrating the sterility and shelf life of the device; (iii) Nonclinical testing evaluating the compatibility of the device in a magnetic resonance environment. (iv) Patient labeling to convey information regarding the safety and compatibility of the device in a magnetic resonance environment, the conditions under which a patient with the device can be safely scanned, and a mechanism for a healthcare provider to obtain detailed information about magnetic resonance safety and compatibility if needed.

Recent Cleared Devices (14 of 14)

RecordDevice NameApplicantDecision DateDecision
K170591Altomed Malhotra Platinum SegmentsAltomed LimitedJun 6, 2017SESE
K150986Contour Eyelid Weight Implants, ThinProfile Eyelid Weight ImplantsMeddev CorporationAug 17, 2015SESE
K021750LID CHAIN EYELID WEIGHTSJedmed Instrument Co.Jan 27, 2003SESE
K011740CONTOUR DESIGN GOLD EYELID IMPLANT, MODEL CONTOUR DESIGN (SERIES 3000)Meddev Corp.Jul 2, 2001SESE
K011115KURZ UPPER EYELID IMPLANT- PLATINUM/IRIDIUM,MODELS REGULAR 4007 003-007, SPECIAL 4007 002, 4007 008-010Heinz Kurz GmbH MedizintechnikMay 2, 2001SESE
K003646SUTUREGROOVE WEIGHT SIZING SETIop, Inc.Feb 22, 2001SESK
K001123KURZ UPPER EYELID IMPLANT SIZERS, MODEL 8000 111Heinz Kurz GmbH MedizintechnikApr 21, 2000SESE
K994289SUTUREGROOVEIop, Inc.Apr 17, 2000SESE
K000127KURZ PURE GOLD UPPER EYELIDS IMPLANT (OBERASCHER), MODEL 4001 02-4001 10Heinz Kurz GmbH MedizintechnikApr 12, 2000SESE
K990224LABTICIAN LID LOAD EXTERNAL EYELID SIZING SETLabtician Ophthalmics, Inc.Apr 12, 1999SESE
K983607LABTICIAN LID LOAD GOLD EYELID WEIGHT IMPLANTSLabtician Ophthalmics, Inc.Jan 8, 1999SESE
K971242BLINK GOLD EVELID WEIGHT (BG 06 THRU BG 28)Ipax, Inc.Dec 17, 1997SESE
K971245BLINK EXTERNAL EYELID WEIGHTIpax, Inc.Jun 20, 1997SESE
K940974EYECLOSE EXTERNAL EYELID WEIGHTSMeddev Corp.Jun 8, 1994SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...