K973192 · Specialty Ultravision, Inc. · LPL · Nov 20, 1997 · Ophthalmic
Device Facts
Record ID
K973192
Device Name
FLEXLENS, FLEXLENS TORIC
Applicant
Specialty Ultravision, Inc.
Product Code
LPL · Ophthalmic
Decision Date
Nov 20, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 886.5925
Device Class
Class 2
Indications for Use
The Specialty 42 and the Specialty T-42 Toric (hefilcon A) Hydrophilic Contact Lenses (clear and visibility tinted) are indicated for daily wear for the correction of refractive ametropia (myopia, hyperopia and astigmatism) in aphakic and/or not-aphakic persons with non-diseased eyes. Eye care practitioners may prescribe the lenses for daily wear in a Frequent Replacement program with scheduled replacement. The lenses may be disinfected using heat, chemical or hydrogen peroxide disinfection systems.
Device Story
Soft contact lenses; hemispherical shells made of hefilcon A (copolymer of 2-hydroxyethyl methacrylate and n-vinyl-2-pyrrolidone). Designed to fit over corneal surface; provide corrective refraction for myopia, hyperopia, and astigmatism. Lathe-cut manufacturing. Prescribed by eye care practitioners for daily wear; includes frequent replacement programs. Patients use lenses to improve visual acuity. Disinfection via heat, chemical, or hydrogen peroxide systems.
Clinical Evidence
No clinical data provided. Substantial equivalence is based on physical, optical, and chemical property comparisons to predicate devices.
Technological Characteristics
Material: hefilcon A (Group 1, low water, non-ionic polymer). Water content: 42%. Manufacturing: Lathe cut. Optical properties: >95% light transmittance, refractive index 1.417. Dimensions: 14.3-14.5 mm diameter, 8.3-8.9 mm base curves. Powers: +20.00 to -20.00 D. Connectivity: None. Sterilization: Compatible with heat, chemical, or hydrogen peroxide systems.
Indications for Use
Indicated for daily wear correction of refractive ametropia (myopia, hyperopia, astigmatism) in aphakic and non-aphakic persons with non-diseased eyes.
Regulatory Classification
Identification
A soft (hydrophilic) contact lens is a device intended to be worn directly against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as a therapeutic bandage. The device is made of various polymer materials the main polymer molecules of which absorb or attract a certain volume (percentage) of water.
Predicate Devices
Flexlens (hefilcon A) Hydrophilic Contact Lens for Daily Wear (Paragon Vision Sciences)
Flexlens Toric (hefilcon A) Hydrophilic Contact Lens for Daily Wear (Paragon Vision Sciences)
Related Devices
K973063 — FREQUENCY 55 (METHAFILCON A) HYDROPHILIC CONTACT LENS FOR DAILY WEAR · Aspect Vision Care, Ltd. · Aug 26, 1997
K963488 — SPECIALTY PROGRESSIVE(METHAFILCON A)MULTIFOCAL SOFT(HYDROPHILIC)CONTACT LENS FOR DAILY WEAR(CLEAR AND TINTED) · Specialty Ultravision, Inc. · Nov 20, 1996
K971164 — FREQUENCY 55 (METHAFILCON A) HYDROPHILIC CONTACT LENS · Aspect Vision Care, Ltd. · May 21, 1997
K011577 — OCU-FLEX 55 SPHERICAL, TORIC,THIN ZONE TORIC,ASPHERICAL,TORIC ASPHERICAL AND THIN ZONE TORIC ASPHERICAL (METHAFILCON A)S · Ocu-Ease Optical Products, Inc. · Jun 19, 2001
K982947 — BIOMEDICS 55 (OCUFILCON D) UV BLOCKING SOFT (HYDROPHILIC) CONTACT LENS · Ocular Sciences Puerto Rico, Inc. · Jan 29, 1999
Submission Summary (Full Text)
{0}------------------------------------------------
# NOV 2 0 1997 K973192
### 510 (k) Summary
### SUBMITTER:
- Company: Specialty UltraVision, Inc. 307 Orchard City Drive Suite 100 Campbell, CA 95008
Contact Person: Ivalee Cohen Director, Regulatory and Clinical Affairs
Telephone: 408-341-0700 408-341-0717 FAX:
- Date Prepared: November 17, 1997
### DEVICE NAME:
| Common Name: | Soft Contact Lens |
|--------------|------------------------------------------------------------------------------------------------------------|
| Trade Names: | Specialty 42 (hefilcon A) Hydrophilic Contact Lens for<br>Daily Wear (clear and visibility tinted) |
| | Specialty T-42 (hefilcon A) Hydrophilic Toric Contact Lens<br>for Daily Wear (clear and visibility tinted) |
FDA Classification: Class II
### SUBSTANTIALLY EQUIVALENT TO:
Flexlens (hefilcon A) Hydrophilic Contact Lens for Daily Wear, Paragon Vision Sciences Flexlens Toric (hefilcon A) Hydrophilic Contact Lens for Daily Wear, Paragon Vision Sciences
Specialty 42 (hefilcon A) Hydrophilic Contact Lens for Daily Wear and tinted) and Specialty T-42 (hefilcon A) Hydrophilic Toric Contact Lens for Daily Wear (clear and visibility tinted) are substantially equivalent in physical, optical and chemical properties, as well as material of manufacture, indications for use and method of manufacture to Paragon Vision Sciences' Flexlens (hefilcon A) Hydrophilic Contact Lens for Daily Wear and Flexlens Toric (hefilcon A). Flexiens lenses received marketing approval pursuant to N17-976. Specialty UltraVision, Inc. has received from the manufacturer of the hefilcon A contact lens buttons, BENZ Research and Development Corp., the right to reference their master file (MAF 872) and 510(k) K972807 regarding the manufacture and distribution of this material.
{1}------------------------------------------------
The hefilcon A lens material has been placed in Group 1, low water, and non-ionic polymers as established by the FDA and located in the Guidance Document for Daily Wear Contact Lenses, Revised Edition, May, 1994.
### DESCRIPTION OF THE DEVICE:
Soft contact lenses are hemispherical shells manufactured of a copolymer of 2hydroxyethyl methacrylate (HEMA) and n-vinyl-2-pyrrolldone (NVP), which yield the appearance of lenses, which are designed to fit over the corneal surface of the eye. These lenses are designed with varying base curves which conform to the shape of the radius of the cornea and center over the apex of the cornea to provide corrective refraction for functional conditions of the eye including myopia (nearsightedness), hyperopia (farsightedness) and astigmatism (multiple foci). Each lens provides corrective power, which is to correspond to the refractive power of the eye to which it is being treated. Each lens is designed with a base curve on the internal side of the lens and an optical zone in the center of the lens which is generally of a diameter greater than 6 mm. Secondary and tertiary curves as well as beveled edge configurations are built into the lens for the purpose of aiding in lens centration and comfort.
| PARAMETER | Specialty 42 Hydrophilic<br>Contact Lens for Daily Wear<br>(clear and visibility tinted) | Flexlens Hydrophilic<br>Contact Lens for Daily Wear |
|--------------------------|------------------------------------------------------------------------------------------|-----------------------------------------------------|
| material | hefilcon A | hefilcon A |
| indication for use | myopia and hyperopia | myopia, hyperopia and<br>astigmatism |
| water content | 42% | 42% |
| light transmittance | >95% | >95% |
| Dk (35° C) | 13.25 X 10-11 | 13.13 X 10-11 |
| powers | +20.00 to -20.00 Diopters | +20.00 to -20.00 Diopters |
| color | clear and blue visibility | clear |
| specific gravity | 1.031 | 1.044 |
| refractive index | 1.417 | 1.413 |
| Method of<br>manufacture | Lathe cut | Lathe cut |
#### SIMILARITIES AND DIFFERENCES
### INDICATIONS FOR USE:
The Specialty 42 and the Specialty T-42 Toric (hefilcon A) Hydrophilic Contact Lenses (clear and visibility tinted) are indicated for daily wear for the correction of refractive ametropia (myopia, hyperopia and astigmatism) in aphakic and/or not-aphakic persons with non-diseased eyes.
Eye care practitioners may prescribe the lenses for daily wear in a Frequent Replacement program with scheduled replacement. The lenses may be disinfected using heat, chemical or hydrogen peroxide disinfection systems.
{2}------------------------------------------------
### PARAMETERS AVAILABLE:
-
i
. . . . .
:
### Specialty 42 (hefilcon A) Hydrophilic Contact Lens (clear and visibility tinted)
| Powers: | +20.00 to -20.00 Diopters |
|-------------|---------------------------|
| Diameter: | 14.3 mm |
| Base Curve: | 8.6 mm |
Specialty T-42 (hefilcon A) Hydrophilic Toric Contact Lens (clear and visibility tinted)
| Powers: | +1.00 to -7.00 Diopters |
|------------------|---------------------------------------------------|
| Diameter: | 14.5 mm |
| Base Curve: | 8.3 mm, 8.6 mm. And 8.9 mm |
| Cylinder powers: | -0.75, -1.25, -1.75, -2.25, -2.75, -3.25 Diopters |
| Axes: | 10°, 20°, 80°, 100°, 160°, 170°, 180° |
{3}------------------------------------------------
Image /page/3/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of three human profiles facing right, stacked on top of each other, forming a single abstract shape.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
NOV 20 1997
Ms. Ivalee Cohen Director of regulatory and Clinical Affairs Specialty Ultra Vision, Inc. 84 West Main Street Freehold, NJ 07728
Re: K973192
Trade Name: Specialty 42 (hefilcon A) Hydrophilic Contact Lens for Daily Wear and Specialty T-42 (hefilcon A) Hydrophilic Toric Contact Lens for Daily Wear (clear and visibility tinted, lathe cut) -------------
Regulatory Class: II Product Code: 86 LPL Dated: August 18, 1997 Received: August 25, 1997
Dear Ms. Cohen:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. -----------------------------
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{4}------------------------------------------------
Page 2 - Ms. Ivalee Cohen
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
A. Ralph Rosenthal
A. Ralph Rosenthal, M.D. Director Division of Ophthalmic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
## INDICATIONS STATEMENT
#### 510(k) Numbør: K973192
#### Device Name:
Specialty 42 (hefilcon A) Hydrophilic Contact Lens for Daily Wear (clear and visibility tinted)
Specialty T-42 (hefilcon A) Hydrophilic Toric Contact Lens for Daily Wear (clear and visibility tinted)
#### Indications For Use:
The Specialty 42 and the Specialty T-42 Toric (hefilcon A) Hydrophilic Contact Lenses (clear and visibility tinted) are indicated for daily wear for the correction of refractive ametropia (myopia, hyperopia and astigmatism) in aphakic and/or not-aphakic persons with non-diseased eyes.
Eye care practitioners may prescribe the lenses for daily wear in a Frequent Replacement program with scheduled replacement. The lenses may be disinfected using heat, chemical or hydrogen peroxide disinfection systems.
### (PLEASE DO NOT WRITE BELOW THIS LINE-GONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use
OR
Over-The-Counter Use_
Daniel W. C. Brown, Ph.D. 8
(Optional Format 1-2-96)
(Division Sign-Off) Division of Ophthalmic Devices K973192 510(k) Number.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.