← Product Code [HQC](/submissions/OP/subpart-e%E2%80%94surgical-devices/HQC) · K961874

# STORZ DP5100 ANTERIOR COLLECTION CASSETTE PACK (K961874)

_Storz Instrument Co. · HQC · Aug 6, 1996 · Ophthalmic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OP/subpart-e%E2%80%94surgical-devices/HQC/K961874

## Device Facts

- **Applicant:** Storz Instrument Co.
- **Product Code:** [HQC](/submissions/OP/subpart-e%E2%80%94surgical-devices/HQC.md)
- **Decision Date:** Aug 6, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 886.4670
- **Device Class:** Class 2
- **Review Panel:** Ophthalmic

## Intended Use

The Storz DP5100 surgical accessory pack contains a single collection cassette. This component is intended to be used as an accessory to the Storz DAISY® (K854508), Storz Protegé® (K921758 and K950114) and Storz PREMIERE® (K894278, K921460, K946227) Ophthalmic Microsurgical Systems as a reservoir for aspirated fluid and tissue collected during anterior segment ophthalmic surgical procedures.

## Device Story

Single-use collection cassette; accessory to Storz DAISY, Protegé, and PREMIERE ophthalmic microsurgical systems. Functions as reservoir for aspirated fluid/tissue during anterior segment surgery. Used in clinical/surgical settings by ophthalmic surgeons. Device collects surgical waste; facilitates fluid management during phacofragmentation procedures.

## Clinical Evidence

Bench testing only; no clinical data provided.

## Technological Characteristics

Anterior collection cassette; material: Phillips K-Resin; single-patient use; sterile; sterilization method: Gamma Irradiation; packaging: Tyvek and PET/PE pouch.

## Regulatory Identification

A phacofragmentation system is an AC-powered device with a fragmenting needle intended for use in cataract surgery to disrupt a cataract with ultrasound and extract the cataract.

## Predicate Devices

- Storz DP5100 Ambulatory Surgery Center (ASC) Collection Cassette Pack ([K894278](/device/K894278.md), [K921758](/device/K921758.md))
- Storz DP4101 Basic Irrigation / Aspiration Pack ([K953078](/device/K953078.md))

## Reference Devices

- Storz DAISY ([K854508](/device/K854508.md))
- Storz Protegé ([K921758](/device/K921758.md), [K950114](/device/K950114.md))
- Storz PREMIERE ([K894278](/device/K894278.md), [K921460](/device/K921460.md), [K946227](/device/K946227.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K961874

storz

AUG 6 1996

# Premarket Notification
## Storz Instrument Company

### 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS

The following information is submitted in accordance with the requirements of 21 CFR 807.92:

**Contact Person:** Regulatory Affairs Associate
**Date Prepared:** May 9, 1996
**Proprietary Name:** Storz DP5100 Anterior Collection Cassette Pack
**Common/Usual Name:** Ophthalmic microsurgical system accessory pack for anterior segment surgical procedures.
**Classification Name:** System, Phacofragmentation (86 HQC).

**Device Description/Intended Use:** The Storz DP5100 surgical accessory pack contains a single collection cassette. This component is intended to be used as an accessory to the Storz DAISY® (K854508), Storz Protegé® (K921758 and K950114) and Storz PREMIERE® (K894278, K921460, K946227) Ophthalmic Microsurgical Systems as a reservoir for aspirated fluid and tissue collected during anterior segment ophthalmic surgical procedures.

**Predicate Device:** The modified Storz DP5100 is substantially equivalent to the existing Storz DP5100 Ambulatory Surgery Center (ASC) Collection Cassette Pack (K894278, K921758), and to the Storz DP4101 Basic Irrigation / Aspiration Pack (K953078).

**Predicate Comparison:** A chart comparing the Storz DP5100, as modified, to the predicate devices, demonstrating substantial equivalence, is attached.

**Submitted by:**

Audrey Swearingen
Storz Instrument Company

STORZ*
3365 Tree Court Industrial Blvd
St. Louis, MO 63122-6694
(314) 225-5051
FAX (314) 225-7365
75

{1}

76
2100217

# DEVICE COMPARISON CHART

## Storz DP5100 Anterior Collection Cassette Pack

|  Device | Storz DP5100, modified | Storz DP5100, existing | Storz DP4101  |
| --- | --- | --- | --- |
|  Intended Use | Collection of Aspirant during Anterior Segment Ophthalmic Surgery | Collection of Aspirant during Anterior Segment Ophthalmic Surgery | Delivery of Irrigant and Collection of Aspirant during Anterior Segment Ophthalmic Surgery  |
|  Components | Anterior Collection Cassette, Instruction Sheet | Anterior Collection Cassette | I/A Tubing, Test Chamber, Anterior Collection Cassette, Instruction Sheet  |
|  Single Patient Use? | Yes | Yes | Yes  |
|  Cassette Material | Phillips K-Resin® | LEXAN™ | Phillips K-Resin®  |
|  Provided Sterile? | Yes | Yes | Yes  |
|  Sterilization Method | Gamma Irradiation | Gamma Irradiation | Gamma Irradiation  |
|  Packaging | Tyvek® and PET/PE Pouch, Six pouches per Box | Tyvek® and PET/PE Pouch, Six Pouches per Box | High-impact Polystyrene Tray With Tyvek® Lid, Six Packs per Box  |

---

**Source:** [https://fda.innolitics.com/submissions/OP/subpart-e%E2%80%94surgical-devices/HQC/K961874](https://fda.innolitics.com/submissions/OP/subpart-e%E2%80%94surgical-devices/HQC/K961874)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
