STORZ D7116 MICROVIT VITRECTOMY CUTTER EXTENSION

K960003 · Storz Instrument Co. · HQC · Aug 29, 1996 · Ophthalmic

Device Facts

Record IDK960003
Device NameSTORZ D7116 MICROVIT VITRECTOMY CUTTER EXTENSION
ApplicantStorz Instrument Co.
Product CodeHQC · Ophthalmic
Decision DateAug 29, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 886.4670
Device ClassClass 2

Intended Use

The Storz device is intended to be used as an accessory to the Storz Microvit® Vitrectomy Cutter to provide a snap-on grip extension for the cutter to facilitate manipulation of the instrument.

Device Story

Accessory snap-on grip extension for Storz Microvit® Vitrectomy Cutter; facilitates instrument manipulation during ophthalmic surgery. Device attaches to existing cutter without altering cutter function. Used by surgeons in clinical/OR settings to improve ergonomics/handling of vitrectomy probes.

Clinical Evidence

Bench testing only; no clinical data provided.

Technological Characteristics

Mechanical snap-on grip extension; annular form factor; non-powered; no electronic or software components.

Indications for Use

Indicated for use during vitrectomy procedures, according to the surgeon's preferred technique.

Regulatory Classification

Identification

A phacofragmentation system is an AC-powered device with a fragmenting needle intended for use in cataract surgery to disrupt a cataract with ultrasound and extract the cataract.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} K960003 storz® AUG 29 1996 Premarket Notification STORZ Instrument Company # 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS The following information is submitted in accordance with the requirements of 21 CFR 807.92: Contact Person: Manager, Regulatory Affairs Date Prepared: December 28, 1995 Proprietary Names: STORZ D7116 Microvit® Vitrectomy Cutter Extension. Common/Usual Name: Ophthalmic surgical system accessory grip extension for vitrectomy cutter. Classification Name: Instrument, vitreous cutting and aspirating, AC powered (36HQC). Device Description/Intended Use: The Storz device is intended to be used as an accessory to the Storz Microvit® Vitrectomy Cutter to provide a snap-on grip extension for the cutter to facilitate manipulation of the instrument. The D7116 does not affect the functioning of the cutter. A drawing of the D7116 and a drawing of the cutter are attached as Exhibits 1 and 2 respectively. Predicate Device: The Storz D7116 is substantially equivalent to a Storz MVS-3201 Vitrectomy Probe Pack (K953575). Predicate Comparison: A chart comparing the Storz D7116 to the predicate device, demonstrating substantial equivalence, is attached. ## Submitted by: Michael H. Southworth Storz Instrument Company 3365 Tree Court Industrial Blvd. St. Louis, MO 63122 Ph. 314/225-5051 STORZ® 3365 Tree Court Industrial Blvd. St. Louis, MO 63122-6694 (314) 225-5051 FAX (314) 225-7365 29 {1} 30 # DEVICE COMPARISON CHART | Device Characteristic | Storz MVS-3201 Vitrectomy Probe | Vitrectomy Probe With D7116 Extension | | --- | --- | --- | | Rear Aspect Annular Grip? | Yes | Yes | | Indication for Use | Vitrectomy, Surgeon's Preferred Technique | Vitrectomy, Surgeon's Preferred Technique | | Alterations to Probe Required? | No | No |
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...