PHOSPHATE BUFFERED SALINE (PBS), PHOSPHATE BUFFERED SALINE WITH CALCIUM, MAGNESIUM, GLUCOSE, PYRUVATE AND PHENOL RED

K991378 · Sage Biopharma · MQL · Sep 24, 1999 · Obstetrics/Gynecology

Device Facts

Record IDK991378
Device NamePHOSPHATE BUFFERED SALINE (PBS), PHOSPHATE BUFFERED SALINE WITH CALCIUM, MAGNESIUM, GLUCOSE, PYRUVATE AND PHENOL RED
ApplicantSage Biopharma
Product CodeMQL · Obstetrics/Gynecology
Decision DateSep 24, 1999
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 884.6180
Device ClassClass 2

Intended Use

Phosphate Buffered Saline (PBS) and Phosphate Buffered Saline, with calcium, magnesium, glucose, pyruvate and phenol red are for in vitro procedures involving the manipulations of gametes and embryos such as oocyte retrieval or embryo transfer, gamete washing, or micromanipulation. They may also be used for cryopreservation of qametes and embryos after the addition of appropriate cryopreservation agent(s).

Device Story

Phosphate Buffered Saline (PBS) and PBS with additives (calcium, magnesium, glucose, pyruvate, phenol red) are liquid media used in clinical reproductive laboratories. These solutions provide a controlled environment for handling gametes and embryos during assisted reproductive technology (ART) procedures. They are used by embryologists or clinicians for washing, micromanipulation, and preparing samples for cryopreservation. The media maintain physiological pH and osmotic balance, supporting cell viability during external manipulation outside the body.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Liquid media consisting of phosphate buffered saline, with or without calcium, magnesium, glucose, pyruvate, and phenol red. Formulated for in vitro use in reproductive procedures. Sterility and chemical composition are maintained to support gamete/embryo viability.

Indications for Use

Indicated for in vitro procedures involving gamete and embryo manipulation, including oocyte retrieval, embryo transfer, gamete washing, micromanipulation, and cryopreservation (with added agents).

Regulatory Classification

Identification

Reproductive media and supplement are products that are used for assisted reproduction procedures. Media include liquid and powder versions of various substances that come in direct physical contact with human gametes or embryos (including water, acid solutions used to treat gametes or embryos, rinsing solutions, sperm separation media, supplements, or oil used to cover the media) for the purposes of preparation, maintenance, transfer or storage. Supplements are specific reagents added to media to enhance specific properties of the media (e.g., proteins, sera, antibiotics, etc.).

Special Controls

*Classification.* Class II (special controls) (mouse embryo assay information, endotoxin testing, sterilization validation, design specifications, labeling requirements, biocompatibility testing, and clinical testing). The device, when it is phosphate-buffered saline used for washing, and short-term handling and manipulation of gametes and embryos; culture oil used as an overlay for culture media containing gametes and embryos; and water for assisted reproduction applications, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/2 description: The image is a black and white seal for the Department of Health & Human Services. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is a stylized image of three overlapping human figures. The figures are abstract and appear to be reaching upwards. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 SEP 2 4 1999 Advanced Reproductive Technologies, Inc. c/o Mr. Grea Holland Requlatory Consultant Holland & Associates 3722 Ave. Sausalito Irvine, CA 92606 Re: K991378 Phosphate Buffered Saline (PBS) and PBS with calcium, magnesium, glucose, pyruvate and phenol red Medium Dated: August 20, 1999 Received: August 23, 1999 Regulatory Class: II 21 CFR §884.6180/Procode: 85 MQL Dear Mr. Holland: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class III (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Requlation (QS) for Medical Devices: General requlation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regult in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnosic devices), piease contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification"(21 CFR 807.97): Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597, or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html". Sincerely yours. CAPT Daniel G. Schultz, M.D. Acting Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {1}------------------------------------------------ Page 1 1 510(k) Number (if known): K991378 Device Name: Phosphate Buffered Salines Indications For Use: Phosphate Buffered Saline (PBS) and Phosphate Buffered Saline, with calcium, magnesium, glucose, pyruvate and phenol red are for in vitro procedures involving the manipulations of gametes and embryos such as oocyte retrieval or embryo transfer, gamete washing, or micromanipulation. They may also be used for cryopreservation of qametes and embryos after the addition of appropriate cryopreservation agent(s). (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) | Prescription Use | | |----------------------|--| | (Per 21 CFR 801.109) | | OR | Over-The-Counter Use | | |--------------------------|--| | (Optional Format 1-2-96) | | ..............................................................................................................................................................................
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...