HyaloGYN Vaginal Hydrating Gel

K150883 · Fidia Farmaceutici S.P.A. · NUC · Sep 1, 2015 · Obstetrics/Gynecology

Device Facts

Record IDK150883
Device NameHyaloGYN Vaginal Hydrating Gel
ApplicantFidia Farmaceutici S.P.A.
Product CodeNUC · Obstetrics/Gynecology
Decision DateSep 1, 2015
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 884.5300
Device ClassClass 2

Indications for Use

HyaloGYN® is a personal lubricant for vaginal application intended to moisturize and lubricate, to enhance the ease and comfort of intimate sexual activity and supplement the body's natural lubrication. This product is compatible with polyisoprene condoms.

Device Story

HyaloGYN is a non-sterile, aqueous, hydrating vaginal gel. It utilizes Hydeal-D (partial benzyl ester of hyaluronic acid), propylene glycol, and a carbomer to create a viscous, mucoadhesive formulation. The device is supplied in an aluminum tube with single-use applicators for patient self-administration. Upon application to the vaginal mucosa, the mucoadhesive properties increase residence time, allowing the hyaluronic acid derivative to hydrate the vaginal epithelium. The device is intended for over-the-counter use to moisturize, lubricate, and enhance comfort during sexual activity. It is compatible with polyisoprene condoms.

Clinical Evidence

Clinical evidence includes a pilot, open, uncontrolled study of 80 women using the device every three days for 30 days. Results showed moisturizing effects on vaginal mucosa. Safety was rated excellent with 98.7% tolerability score and no adverse events or alterations to the vaginal ecosystem reported.

Technological Characteristics

Non-sterile, aqueous gel containing Hydeal-D (partial benzyl ester of hyaluronic acid), propylene glycol, carbomer, preservatives, and sodium hydroxide. Mucoadhesive properties. Packaged in aluminum tube with single-use applicators. Shelf life: 36 months. Condom compatibility tested per ASTM D7661-10. Biocompatibility tested per ISO 10993-5, -10, and -11.

Indications for Use

Indicated for individuals requiring vaginal moisturization and lubrication to enhance comfort during sexual activity and supplement natural lubrication.

Regulatory Classification

Identification

A condom is a sheath which completely covers the penis with a closely fitting membrane. The condom is used for contraceptive and for prophylactic purposes (preventing transmission of sexually transmitted infections). The device may also be used to collect semen to aid in the diagnosis of infertility.

Special Controls

*Classification.* (1) Class II (special controls) for condoms made of materials other than natural rubber latex, including natural membrane (skin) or synthetic.(2) Class II (special controls) for natural rubber latex condoms. The guidance document entitled “Class II Special Controls Guidance Document: Labeling for Natural Rubber Latex Condoms Classified Under 21 CFR 884.5300” will serve as the special control. See § 884.1(e) for the availability of this guidance document.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features the department's name in a circular arrangement around a symbol. The symbol consists of three stylized human profiles facing to the right, stacked on top of each other. The profiles are connected by flowing lines, creating a sense of unity and movement. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 September 1, 2015 Fidia Farmaceutici Spa % Vivian Kelly US Agent/Regulatory Affairs Manager Fidia Pharma Usa Inc Morris Corporate Center 1, Building C, 300 Interpace Parkway Parsippany, New Jersey 07054 Re: K150883 Trade/Device Name: HyaloGYN Vaginal Hydrating Gel Regulation Number: 21 CFR 884.5300 Regulation Name: Condom Regulatory Class: Class II Product Code: NUC Dated: August 4. 2015 Received: August 4, 2015 Dear Vivian Kelly: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device {1}------------------------------------------------ related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # Joyce M. Whang -S for for Benjamin R. Fisher, Ph.D. Director Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K150883 Device Name HyaloGYN® Vaginal Hydrating Gel #### Indications for Use (Describe) HyaloGYN® is a personal lubricant for vaginal application intended to moisturize and lubricate, to enhance the ease and comfort of intimate sexual activity and supplement the body's natural lubrication. This product is compatible with polyisoprene condoms. Type of Use (Select one or both, as applicable) | <label><input type="checkbox"/> Prescription Use (Part 21 CFR 801 Subpart D)</label> | |------------------------------------------------------------------------------------------------| | <label><input checked="" type="checkbox"/> Over-The-Counter Use (21 CFR 801 Subpart C)</label> | ### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ Image /page/3/Picture/1 description: The image contains the logo for Fidia Pharma USA Inc. The logo consists of a blue circular graphic on the left, which appears to be an abstract representation of a globe or a cell. To the right of the graphic, the word "fidia" is written in a bold, blue sans-serif font. Below "fidia", the text "Pharma USA Inc" is written in a smaller, lighter blue font. #### K150883 #### 510(k) Summary This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR § 807.92. | Applicant: | Fidia Farmaceutici, S.p.A.<br>Via Ponte della Fabbrica 3/A<br>35031 Abano Terme (PD) - Italy | |-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Contact Person: | Vivian Kelly, MS, RAC<br>Regulatory Affairs Manager<br>Phone: 973-577-6202<br>Fidia Pharma USA Inc.<br>Morris Corporate Center 1, Building C<br>300 Interpace Parkway,<br>Parsippany, New Jersey 07054 | | Date Prepared: | September 1, 2015 | #### Device Information: | Proprietary Name: | HyaloGYN® Vaginal Hydrating Gel | |-----------------------------|---------------------------------| | Device Common Name | Vaginal Moisturizer | | Device Classification Name: | Personal Lubricant | | Regulation Number | 21 CFR 884.5300 | | Regulation Name | Condom | | Regulatory Class | II | | Product Code | NUC (lubricant, personal) | ### Legally Marketed Predicate Device to Which Substantial Equivalence is Claimed: - · HyaloGYN® Vaginal Hydrating Gel, Fidia Farmaceutici, S.p.A. K094039 ### Legally Marketed Reference Device Used to Support Substantial Equivalence: - · Replens Long-Lasting Vaginal Moisturizer, Lil' Drug Store Products, Inc. K101098 - · Elegance Woman's Lubricant, Elegance K070587 ### Description of Device: HyaloGYN is a line extension to add a formulation of HyaloGYN not made with parabens. It is a nonsterile, colorless, odorless, transparent, aqueous, hydrating gel that contains "Hydeal-D®" (a partial benzyl ester of hyaluronic acid), propylene glycol, a carbomer, preservatives and sodium hydroxide (to balance the pH). The hyaluronic acid is manufactured using a bacterial fermentation process. {4}------------------------------------------------ HyaloGYN is a non-hormonal vaginal moisturizer intended to hydrate the vaginal epithelium because of the strong hydrating properties of its hyaluronic acid derivative component. The carbomer and propylene glycol combine with the hyaluronic acid derivative to enable HyaloGYN to achieve its thick, viscous gel form, and the mucoadhesive properties to allow it to adhere to the vaginal mucosa, enhancing the residence time, thus hydrating this tissue. It is provided in an aluminum tube and packaged together with single-use applicators in a cardboard box. HyaloGYN has a shelf life of 3 years. ### Technological Characteristics of the Device: The proposed device formula is proprietary and consists of safe, water-soluble ingredients similar to the identified predicate device. The comparison of key design features and the performance testing demonstrate that HyaloGYN is substantially equivalent to its predicate in regards its technological characteristics including intended use, indications for use, design, materials, operational principles and performance characteristics. The device is designed to meet the following Product Specifications at release: Appearance, odor, color weight, pH, hyaluronic acid content, Total Aerobic Microbial Count, Total combined yeasts/molds count, absence of common pathogens (Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans), viscosity, and osmolality. ### Indications for Use: HyaloGYN® is a personal lubricant for vaginal application intended to moisturize and lubricate, to enhance the ease and comfort of intimate sexual activity and supplement the body's natural lubrication. This product is compatible with polyisoprene condoms. # Summary of Performance Data: # Biocompatibility Testing The following biocompatibility studies were conducted and confirm it is safe for the proposed indication: - . In vitro Cytotoxicity Assay per ISO 10993-5 - . Sensitization (Guinea Pig Maximization Test) per ISO 10993-10 - . Vaginal Irritation Test per ISO 10993-10 - . Acute Systemic Toxicity Rat per ISO 10993-11 ### Performance Testing - Bench Condom compatibility testing was conducted per ASTM D7661-10. The results concluded that the subject device product is compatible with polyisoprene condoms. {5}------------------------------------------------ # Performance Testing - Clinical Fidia conducted the following study on the subject device and a summary is provided below: ·Tempera G. Evaluation of the Tolerability and Efficacy of Hyalgel Vaginal (HYALOgin™) for the Treatment of Vaginal Dryness and Irritation Final Clinical Report, September 22, 1998 A pilot, open, uncontrolled clinical study conducted in Italy to assess the safety and effectiveness of HyaloGYN. A total of 80 women were enrolled at a single site. They were instructed to use the test product every three days for 30 days. Follow-up visits were performed on Days 7 and 21, with the final visit taking place three days after the last application of test product. The results obtained in this study demonstrated that the test material had moisturizing effects on the vaginal mucosa. Safety was considered to be excellent as demonstrated by the absence of adverse events and the investigator's overall assessment of tolerability score (98.7%). There were no alterations of the vaginal ecosystem. This study supports the substantial equivalence of the subject device to Replens, the reference device, cleared in K101098 as a personal lubricant/moisturizer and demonstrates the safe and effective use of HyaloGYN as a personal lubricant to successfully supplementing the body's natural lubrication. Stability Testing HyaloGYN® has a 36-months shelf life based on the results of shelf life testing. ## Conclusion: HyaloGYN® Hydrating Gel is substantially equivalent to the predicate HyaloGYN® Hydrating Gel and the reference predicate device, Replens Long-lasting Vaginal Moisturizer and Elegance Woman's Lubricant. The intended use and fundamental technology of the system remain unchanged. Furthermore, performance testing and other supporting information sufficiently demonstrate the substantial equivalence of the subject device to other vaginal moisturizers. Based on this information, the subject device does not raise any new issues regarding the safety or efficacy.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...