HIB · Speculum, Vaginal, Nonmetal

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 2

Overview

Product CodeHIB
Device NameSpeculum, Vaginal, Nonmetal
Regulation21 CFR 884.4530
Device ClassClass 2
Review PanelObstetrics/Gynecology

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 72)

Showing 20 most recent of 72 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K252208JFord Speculum Sleeve™Ford Medtech, LLCMar 6, 2026SESE
K133857BRELLA-SPEC(TM) VAGINAL SPECULUMProa Medical, Inc.Apr 28, 2014SESE
K132668IOB DISPOSABLE SPECULUMIob Medical, Inc.Jan 17, 2014SESE
K130046CLEARSPEC SINGLE USE VAGINAL SPECULUMClearspec, LLCAug 6, 2013SESE
K120743SPECULUM, VAGINAL, NONMETALWelch Allyn, Inc.Mar 23, 2012SESE
K110766KOLPLUX SYSTEMKolplast CI LtdaSep 15, 2011SESE
K092870NON-STERILE DISPOSABLE VAGINAL SPECULUMKunshan Deyi Plastic Co., Ltd.Feb 16, 2010SESE
K091937OFFICE-SPEC DISPOSABLE SIDE-OPENING SPECULUMObp CorporationSep 9, 2009SESE
K072942MEDLINE DISPOSABLE VAGINAL SPECULUMMedline Industries, Inc.Feb 8, 2008SESE
K072762DEPALT VAGINAL SPECUIM AND DEPALT LIGHTING SYSTEMDepalt, Inc.Jan 22, 2008SESE
K070964KLEENSPEC SINGLE USE VAGINAL SPECULUM AND 790 SERIES CORDLESS ILLUMINATION SYSTEMWelch Allyn, Inc.May 18, 2007SESE
K061339HIERSPEC SPECULUMMedical Products Div.Sep 19, 2006SESE
K060129IGS VAGINAL SPECULUMInnovative Gynecological Solutions, LLCMay 4, 2006SESE
K052420G-SPEC ARTICULATED WEIGHTED VAGINAL SPECULUMGynova, LLCApr 6, 2006SESE
K052192FEMSPCE-S DISPOSABLE STERILE VAGINAL SPECULUM, MODEL ST-IFemspec LLCFeb 2, 2006SESE
K052912YUSHENG DISPOSABLE VAGINAL SPECULUMZhejiang Yusheng Medical Instrument Co. , Ltd.Dec 15, 2005SESE
K052314DYNAREX VAGINAL SPECULA 4900, MODELS 4911-SMALL, 4912-MEDIUM, 4913-LARGEDynarex Corp.Nov 9, 2005SESE
K050887GONGDONG DISPOSABLE VAGINAL SPECULUMZhejiang Gongdong Medical Plastic FactoryJul 11, 2005SESE
K041757FEMSPEC DISPOSABLE VAGINAL SPECULUMFemspec LLCDec 23, 2004SESE
K042950VAG O SPECULUM, MODELS VS1, VM1, VL1Panatrex, Inc.Nov 30, 2004SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...