AMS PELVIC FLOOR REPAIR SYSTEM

K051485 · American Medical Systems, Inc. · OTO · Aug 3, 2005 · General, Plastic Surgery

Device Facts

Record IDK051485
Device NameAMS PELVIC FLOOR REPAIR SYSTEM
ApplicantAmerican Medical Systems, Inc.
Product CodeOTO · General, Plastic Surgery
Decision DateAug 3, 2005
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.3300
Device ClassClass 2
AttributesTherapeutic

Intended Use

The AMS Pelvic Floor Repair System is intended for use where the connective tissue has ruptured or for implantation to reinforce soft tissues where weakness exists in the urological, gynecological and gastroenterological anatomy. This includes but is not limited to the following procedures: pubourethral support, including urethral slings for the treatment of incontinence, vaginal wall prolapse repairs including anterior and posterior wall repairs, vaginal suspension, reconstruction of the pelvic floor and tissue repair.

Device Story

AMS Pelvic Floor Repair System consists of surgical needles and mesh; used for pelvic floor repair, soft tissue reinforcement, and incontinence treatment. Device implanted by physicians in clinical settings to address tissue rupture or weakness. Mesh provides structural support to pelvic anatomy; needles facilitate precise placement. System functions as a mechanical implant; no electronic or algorithmic components. Benefits include restoration of anatomical support and treatment of prolapse/incontinence.

Clinical Evidence

Bench testing only; no clinical data provided.

Technological Characteristics

System comprises surgical needles and polymeric surgical mesh. Mechanical device; no energy source, software, or connectivity. Sterilization method not specified.

Indications for Use

Indicated for patients requiring connective tissue repair or soft tissue reinforcement in urological, gynecological, or gastroenterological anatomy, including treatment for incontinence, vaginal wall prolapse, vaginal suspension, and pelvic floor reconstruction.

Regulatory Classification

Identification

Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # AUG 3 - 2005 ### 510(k) Summary AMS Pelvic Floor Repair System ## 510(k) Number_Ko51485 #### Date of Summary Preparation: June 3, 2005 #### Submitter/Contact Person: Elsa A. Linke Regulatory Affairs Specialist American Medical Systems 10700 Bren Rd. W Minnetonka, MN 55343 Phone: (952) 930-6000 Fax: (952) 930-6496 #### Device Name and Classification: Trade Name: AMS Pelvic Floor Repair System Common/Usual Name: Surgical Mesh Classification Name: Surgical Mesh, polymeric Product Code: OTO, OTO, OTP Classification: Class II ### Manufacturing Location: American Medical Systems, Inc. 10700 Bren Rd. West Minnetonka, MN 55343 ### Predicate Devices: AMS Apogee - K040537 AMS Perigee - K040623 AMS Pre-Connected Apogee, Perigee, & BioArc - K050445 AMS Porcine Dermis - K050445 AMS Sparc Sling System -K021263 AMS Monarc Sling System - K023516 AMS Silicone-Coated Sling and Surgical Mesh - K002721 AMS Large Pore Polypropylene Mesh - K040521 #### Indications for Use: The AMS Pelvic Floor Repair System is intended for use where the connective tissue has ruptured or for implantation to reinforce soft tissues where weakness exists in the urological, gynecological and gastroenterological anatomy. This includes but is not limited to the following procedures: pubourethral support, including urethral slings for the treatment of incontinence, vaginal wall prolapse repairs including anterior and posterior wall repairs, vaginal suspension, reconstruction of the pelvic floor and tissue repair. {1}------------------------------------------------ ### Device Description: vice Description. The AMS Pelvic Floor Repair System consists of needles and mesh used to repair the pelvic floor. # Summary of Testing minary of Testing The components of the AMS Pelvic Floor Repair System have been tested for The oumponents of the fine ince requirements and found to be substantially equivalent to the predicate devices. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized eagle with three tail feathers. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" are arranged in a circular fashion around the eagle. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 Ms. Elsa A. Linke Senior Regulatory Affairs Specialist American Medical Systems 10700 Bren Road West MINNETONKA MN 55343 SEP 2 8 20:2 Re: K051485 Trade/Device Name: AMS Pelvic Floor Repair System Regulation Number: 21 CFR 878.3300 Regulation Name: Surgical mesh Regulatory Class: II Product Code: OTO, OTP Dated: June 3, 2005 Received: June 6, 2005 Dear Ms. Linke: This letter corrects our substantially equivalent letter of August 3, 2005. We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must {3}------------------------------------------------ comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours. Sincerely yours, Benjamin R. Perkins Beniamin R. Fisher, Ph.D. Director Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ #### INDICATIONS FOR USE 510(k) Number (if known): Device Name: AMS Pelvic Floor Repair System Indications For Use: The AMS Pelvic Floor Repair System is intended for use where the connective tissue has ruptured or for implantation to reinforce soft tissues where weakness exists in the urological, gynecological and gastroenterological anatomy. This includes but is not limited to the following gastrological and and myport, including urethral slings for the treatment of incontinence, vaginal wall prolapse repairs including anterior and posterior wall repairs, vaginal suspension, reconstruction of the pelvic floor and tissue repair. Prescription Use X (Per 21 CFR 801 Subpart D) AND/OR Over-The Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Eda (Division Sign-Off) Division of General, Restorative and Neurological Devices Neurological Devices 510(k) Number K051445 12 Page 1 of / Page 18 of 133
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...