STORC INTRAUTERINE PRESSURE CATHETER

K954955 · Clinical Innovations, Inc. · HFN · Apr 17, 1996 · Obstetrics/Gynecology

Device Facts

Record IDK954955
Device NameSTORC INTRAUTERINE PRESSURE CATHETER
ApplicantClinical Innovations, Inc.
Product CodeHFN · Obstetrics/Gynecology
Decision DateApr 17, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 884.2700
Device ClassClass 2

Indications for Use

This catheter is for use on patients requiring intrapartum, intrauterine pressure monitoring.

Device Story

Disposable, sterile, single-patient-use intrauterine pressure monitoring system; used during labor and delivery. Device features pressure sensor at catheter tip, soft elastomeric tip to reduce perforation risk, and lumen with female luer connector for amniotic fluid access. Operated by clinicians in clinical settings. Provides real-time intrauterine pressure signal to external monitoring equipment via external zeroing. Soft tip design enhances patient safety; disposable nature prevents cross-contamination. Clinical utility includes monitoring pressure, accessing amniotic space, and maintaining signal integrity for labor management.

Clinical Evidence

Clinical studies and physician evaluations conducted. Results demonstrated the device is as effective or more effective than predicate devices regarding intrauterine pressure signal integrity, ease of use, amniotic space access, device retention, and zeroing/drift signal stability. Bench testing on fresh placenta confirmed lower perforation risk compared to predicates. Mechanical integrity and biocompatibility verified via independent laboratory testing.

Technological Characteristics

Disposable intrauterine pressure catheter; soft elastomeric tip; pressure sensor at tip; female luer connector for amniotic access; external zeroing mechanism; sterile, single-patient use; biocompatible materials.

Indications for Use

Indicated for patients requiring intrapartum, intrauterine pressure monitoring.

Regulatory Classification

Identification

An intrauterine pressure monitor is a device designed to detect and measure intrauterine and amniotic fluid pressure with a catheter placed transcervically into the uterine cavity. The device is used to monitor intensity, duration, and frequency of uterine contractions during labor. This generic type of device may include the following accessories: signal analysis and display equipment, patient and equipment supports, and component parts.

Predicate Devices

Submission Summary (Full Text)

{0} K954955 K954955 # 510(k) Summary 4PR 17 1996 Submitter: Clinical Innovations, Inc. Name: Wm. Dean Wallace Address: 6477 So. Cottonwood St., Murray, UT 84107 Telephone: (801) 268-8200 Trade Name: STORC Intrauterine Pressure Catheter Common Name: Intrauterine Pressure Catheter Classification Name: Catheter, Intrauterine and Introducer The legally marketed devices to which equivalence is claimed include the MX 4042 Series Intrauterine Pressure Catheter from Medex, the Meditrace Disposable Intrauterine Catheter from Graphic Controls, the Intrauterine Catheter from Telos, and the IUC - Intrauterine Catheter (INTRAN) from Utah Medical Products. Description of the device: STORC™ is a Disposable Intrauterine Pressure Monitoring System. This product is a sterile, single patient use catheter. Intended use: This catheter is for use on patients requiring intrapartum, intrauterine pressure monitoring. The STORC Intrauterine Pressure Catheter is substantially equivalent to the predicate devices because: It has the same intended uses, namely, - intrauterine pressure measurement and monitoring - port for amniotic fluid access, It has the same basic technological characteristics as predicate devices, namely, - pressure sensor located at catheter tip, - soft tip for lower risk of perforation, - markings for catheter insertion, - low-cost disposable in order to avoid cross contamination, - port and lumen with female luer connector for access to amniotic space, - external zeroing of pressure. It uses the same or similar materials, all of which have been shown to be biocompatible and to function well in the intended application, {1} The soft elastomeric tip is a further advantage that adds safety. The safety and effectiveness are similar or better than existing devices as demonstrated in the laboratory and clinical testing. ## Safety Laboratory testing has shown that in the following areas the STORC Intrauterine Pressure Catheter is safe: - Perforation: bench testing on fresh placenta showed that the STORC is less likely to perforate than predicate devices. - Mechanical integrity: laboratory testing and basic design assure that no parts will come loose and be left in the patient. - Biocompatibility and infection: independent lab testing show that the materials used in the STORC are safe for use in this application. In addition, clinical studies including physician evaluation verified the safe nature of the STORC Intrauterine Pressure Catheter. ## Effectiveness The clinical trials showed that the STORC Intrauterine Pressure Catheter was as effective or more effective than the predicate devices in the following areas: - integrity of intrauterine pressure signal - ease of use - amniotic space access - device retention - zeroing and drift signal stability The laboratory testing verified the performance standards in terms of sensor accuracy, mechanical integrity, and overall performance. Wm. Dean Wallace, M.D., Ph.D. 10-23-95 Date
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...