- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- MiscellaneousMiscellaneous
- Subpart B—Clinical Chemistry Test SystemsCFR Sub-Part
- Subpart B—Diagnostic DevicesCFR Sub-Part
- Subpart B—Obstetrical and Gynecological Diagnostic DevicesCFR Sub-Part
- Subpart C—Cardiovascular Monitoring DevicesCFR Sub-Part
- Subpart C—Obstetrical and Gynecological Monitoring DevicesCFR Sub-Part
- Subpart D—Cardiovascular Prosthetic DevicesCFR Sub-Part
- Subpart D—Obstetrical and Gynecological Prosthetic DevicesCFR Sub-Part
- Subpart D—Physical Medicine Prosthetic DevicesCFR Sub-Part
- Subpart D—Prosthetic DevicesCFR Sub-Part
- Subpart E—Obstetrical and Gynecological Surgical DevicesCFR Sub-Part
- Subpart F—Obstetrical and Gynecological Therapeutic DevicesCFR Sub-Part
- Subpart F—Therapeutic DevicesCFR Sub-Part
- Subpart G—Assisted Reproduction DevicesCFR Sub-Part
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Plethysmograph, Air Displacement For Body Composition Analysis
- Page Type
- Product Code
- Definition
- To measure the total body volume and weight for calculating the estimated body composition (total body fat and total body lean mass).
- Physical State
- An air-tight, dual compartment fiberglass and plexiglas chamber that the subject enters
- Technical Method
- Uses Boyle's law in conjunction with the two precisely-sized compartments to determine the volume occupied by the subject's body. Average total body density is calculated from the weight and volume determined by the device. Empirical equations, as a function of density of known tissue types, are then used to estimate body composition parameters.
- Target Area
- whole body
- Regulation Medical Specialty
- Cardiovascular
- Review Panel
- Obstetrical and Gynecological
- Submission Type
- 510(K)
- Device Classification
- Class 2
- Regulation Number
- 870.2770
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 870.2770 Impedance plethysmograph
§ 870.2770 Impedance plethysmograph.
(a) Identification. An impedance plethysmograph is a device used to estimate peripheral blood flow by measuring electrical impedance changes in a region of the body such as the arms and legs.
(b) Classification. Class II (special controls). The device, when it is a body composition analyzer which is not intended to diagnose or treat any medical condition, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.
[45 FR 7907, Feb. 5, 1980, as amended at 84 FR 71812, Dec. 30, 2019]