MICROSPAN HYSTEROSCOPE SHEATH
Device Facts
| Record ID | K961506 |
|---|---|
| Device Name | MICROSPAN HYSTEROSCOPE SHEATH |
| Applicant | Imagyn Medical, Inc. |
| Product Code | HIH · Obstetrics/Gynecology |
| Decision Date | Jul 3, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 884.1690 |
| Device Class | Class 2 |
Indications for Use
The MicroSpan Hysteroscope Sheath is indicated for use in providing access to the uterine cavity for the Imagyn Hysteroscope or other hysteroscopic instruments during diagnostic and operative hysteroscopic procedures.
Device Story
MicroSpan Hysteroscope Sheath provides access to uterine cavity for hysteroscopes/instruments; features irrigation/insufflation and aspiration ports plus instrument channel. Used in clinical settings by physicians during diagnostic/operative hysteroscopy. Maintains uterine distention during insertion. Single-use, sterile device.
Clinical Evidence
Bench testing only. Leak and flow testing performed to demonstrate adequate performance for intended use.
Technological Characteristics
Constructed of metal and plastic components. Features irrigation/insufflation and aspiration ports and an instrument channel. Sterile, single-use device.
Indications for Use
Indicated for patients undergoing diagnostic and operative hysteroscopic procedures requiring access to the uterine cavity.
Regulatory Classification
Identification
A hysteroscope is a device used to permit direct viewing of the cervical canal and the uterine cavity by a telescopic system introduced into the uterus through the cervix. It is used to perform diagnostic and surgical procedures other than sterilization. This generic type of device may include obturators and sheaths, instruments used through an operating channel, scope preheaters, light sources and cables, and component parts.
Predicate Devices
- Imagyn Hysteroscope Sheaths
- Olympus Hysteroscope 4/5 mm System
- Circon ACMI Office Operative Hysteroscope Sheath
- Karl Storz Mini-Hysteroscopy Operating Sheath
Related Devices
- K961605 — KARL STORZ 10.5 FR. FLEXIBLE HYSTEROSCOPE · KARL STORZ Endoscopy-America, Inc. · Nov 13, 1996
- K241987 — Single-Use Video Hysteroscope (RP-G-C24, RP-G-C0101) · Guangzhou Red Pine Medical Instrument Co., Ltd. · Aug 2, 2024
- K013870 — SMITH & NEPHEW OPERATIVE HYSTEROSCOPE, MODEL 7209208; SMITH & NEPHEW CONTINUOUS FLOW SHEATH, MODEL 8105224 · Smith & Nephew, Inc. · Jan 17, 2002
- K972426 — MICROSPAN GOLD HYSTEROSCOPE AND MICROSPAN HYSTEROSCOPE SHEATH · Imagyn Medical, Inc. · Sep 23, 1997
- K182006 — Omni Hysteroscope, Omni Hysteroscope Kits, Omni Sheaths · Hologic, Inc. · Dec 6, 2018