IMT LOUPE-COLPOSCOPE
Device Facts
| Record ID | K963593 |
|---|---|
| Device Name | IMT LOUPE-COLPOSCOPE |
| Applicant | Inventive Medical Technology |
| Product Code | HEX · Obstetrics/Gynecology |
| Decision Date | Apr 22, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 884.1630 |
| Device Class | Class 2 |
Indications for Use
Approval is sought for this device with the intent of marketing it. It is truly felt that it is a very safe instrument for attendants to use for evaluations and aid to certain treatments.
Device Story
Portable, self-contained colposcope; features integrated light source, green filter, and variable magnification. Used by clinicians for patient evaluations and treatment assistance; provides magnified visualization of tissue. Designed for use in diverse settings including remote areas, emergency situations, and standard clinical environments. Output is direct visual observation by the clinician; facilitates diagnostic assessment and biopsy guidance. Performance compared to standard operating microscopes; portability offers utility in resource-limited settings.
Clinical Evidence
Blinded control study of 61 patients; compared Loupe-Colposcope performance against Zeiss OM-1 operating microscope. Diagnoses validated against Papanicolaou smear and histological biopsy results. Remainder of cases compared to concurrent Papanicolaou smears and biopsy pathology. No adverse effects reported.
Technological Characteristics
Portable, self-contained optical device; includes integrated light source, green filter, and variable magnification mechanism. Mechanical/optical design.
Indications for Use
Indicated for use by clinicians for colposcopic evaluations and as an aid to treatment procedures in patients requiring cervical or related tissue examination.
Regulatory Classification
Identification
A colposcope is a device designed to permit direct viewing of the tissues of the vagina and cervix by a telescopic system located outside the vagina. It is used to diagnose abnormalities and select areas for biopsy. This generic type of device may include a light source, cables, and component parts.
Special Controls
*Classification.* Class II (special controls). The device, when it is a standard colposcope (or colpomicroscope) that uses only a white light source, does not use filters other than a green filter, does not include image analysis software, and is not smartphone-based, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.
Reference Devices
- Zeiss OM-1 operating microscope
Related Devices
- K132423 — THE GYNOCULAR · Gynius AB · Apr 8, 2014
- K031639 — INTERMED ZOOM COLPOSCOPE · Intermed Group, Inc. · Aug 22, 2003
- K181034 — Pocket Colposcope System · Hadleigh Health Technologies, LLC · Sep 21, 2018
- K140754 — COOPER SURGICAL LEISEGANG COLPOSCOPE SYSTEM · CooperSurgical, Inc. · Oct 23, 2014
- K031436 — MEDISCOPE · Sometech Corporation · Dec 19, 2003