We're working on improving this tool, so please
email us
suggestions.
Sign up
for email updates to learn about new features.
✕
FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Assisted Reproduction Devices
CFR Sub-Part
Cardiovascular Monitoring Devices
CFR Sub-Part
Cardiovascular Prosthetic Devices
CFR Sub-Part
Clinical Chemistry Test Systems
CFR Sub-Part
Diagnostic Devices
CFR Sub-Part
Miscellaneous
Miscellaneous
Obstetrical and Gynecological Diagnostic Devices
CFR Sub-Part
Obstetrical and Gynecological Monitoring Devices
CFR Sub-Part
Obstetrical and Gynecological Prosthetic Devices
CFR Sub-Part
Obstetrical and Gynecological Surgical Devices
CFR Sub-Part
HER
Pelvimeter, External
1
Product Code
FHG
Bell, Circumcision
2
Product Code
FHJ
Shield, Circumcision
2
Product Code
HCY
Curette, Uterine
1
Product Code
HCZ
Forceps, Surgical, Gynecological
2
Product Code
HDA
Forceps, Obstetrical
2
Product Code
HDB
Extractor, Vacuum, Fetal
2
Product Code
HDC
Tenaculum, Uterine
2
Product Code
HDD
Table, Obstetrical, Ac-Powered (And Accessories)
2
Product Code
HDE
Hook, Fibroid, Gynecological
1
Product Code
HDF
Speculum, Vaginal, Metal
1
Product Code
HDG
Speculum, Vaginal, Metal, Fiberoptic
1
Product Code
HDH
Needle, Cerclage, Gynecological
1
Product Code
HDI
Hook, Destructive, Obstetrical
2
Product Code
HDJ
Scissors, Umbilical
1
Product Code
HDK
Scissors, Episiotomy
1
Product Code
HDL
Retractor, Vaginal
1
Product Code
HDM
Packer, Uterine
1
Product Code
HDN
Dilator, Cervical, Expandable
3
Product Code
HDP
Elevator, Uterine
2
Product Code
HDQ
Dilator, Cervical, Fixed Size
1
Product Code
HDY
Dilator, Cervical, Hygroscopic-Laminaria
2
Product Code
HDZ
Knife, Cervical Cone
2
Product Code
HFB
Forceps, Biopsy, Gynecological
1
Product Code
HFG
Coagulator, Laparoscopic, Unipolar (And Accessories)
2
Product Code
HFH
Coagulator, Hysteroscopic (And Accessories)
2
Product Code
HFI
Coagulator, Culdoscopic (And Accessories)
2
Product Code
HFW
Clamp, Umbilical
2
Product Code
HFX
Clamp, Circumcision
2
Product Code
HFZ
Craniotribe
2
Product Code
HGA
Cranioclast
2
Product Code
HGC
Clamp, Uterine
1
Product Code
HGD
Applicator, Vaginal
1
Product Code
HGE
Amniotome
1
Product Code
HGI
Electrocautery, Gynecologic (And Accessories)
2
Product Code
HHF
Remover, Intrauterine Device, Contraceptive, Hook-Type
1
Product Code
HHG
Dilator, Cervical, Vibratory
3
Product Code
HHM
Sound, Uterine
1
Product Code
HHN
Cleidoclast
2
Product Code
HHO
Screw, Fibroid, Gynecological
2
Product Code
HHP
Table, Obstetrical, Manual (And Accessories)
2
Product Code
HHR
Laser, Surgical, Gynecologic
2
Product Code
HHT
Spatula, Cervical, Cytological
2
Product Code
HIB
Speculum, Vaginal, Nonmetal
2
Product Code
HIC
Speculum, Vaginal, Nonmetal, Fiberoptic
2
Product Code
HIM
Electrocautery, Endoscopic And Accessories
2
Product Code
HIN
Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)
2
Product Code
K
14
2525
PK Lap Loop
2
Cleared 510(K)
K
13
0305
LINA BIPOLAR LOOP; STANDARD SIZE, LARGE SIZE, EXTRA LARGE SIZE
2
Cleared 510(K)
K
12
2983
KSEA BIPOLAR ELECTRODE
2
Cleared 510(K)
K
12
2605
PKS BILL
2
Cleared 510(K)
K
11
3080
TUBALGATOR
2
Cleared 510(K)
K
11
1751
VERSAPOINT II BIPOLAR ELECTROSURGERY GENERATOR, VERSAPOINT II 44MM ANGLED LOOP ELECTRODE, VERSAPOINT II FOOTSWITCH, VERS
2
Cleared 510(K)
K
11
1059
GYRUS ACMIL BIPOLARLAPROSCOPIC LOOP (PKS BILL)
2
Cleared 510(K)
K
99
0147
BIPOLAR FORCEPS, KLEPPINGER INSERT, MODEL #'S 8393.741,8393.771,8394.741,8394.771
2
Cleared 510(K)
K
97
1565
BICOAG COAGULATING FORCEPS
2
Cleared 510(K)
K
92
6517
ELMED LBC 50-P
2
Cleared 510(K)
Show All 16 Submissions
KNA
Instrument, Manual, Specialized Obstetric-Gynecologic
2
Product Code
KNB
Instrument, Destructive, Fetal, Obstetric
2
Product Code
KNC
Table, Obstetric (And Accessories)
2
Product Code
KNF
Coagulator-Cutter, Endoscopic, Unipolar (And Accessories)
2
Product Code
KOH
Instrument, Manual, General Obstetric-Gynecologic
1
Product Code
LBX
Pelvimeter, Internal
2
Product Code
LKF
Cannula, Manipulator/Injector, Uterine
2
Product Code
LLW
Laser, Neodymium:Yag For Gynecologic Use
2
Product Code
MDG
System, Intrafallopian Cannula
2
Product Code
MLS
Labor And Delivery Kit
2
Product Code
MLT
Pelvic Exam Kit
2
Product Code
MOV
Catheters, Salpingography
2
Product Code
MPU
Source, Chemiluminescent Light
2
Product Code
NBZ
Clamp And Cutter, Umbilical
2
Product Code
NMG
Forceps, Biopsy, Gynecological, Reprocessed
2
Product Code
OHC
Obstetrical Vacuum Delivery Kit
2
Product Code
PBQ
Fixation, Non-Absorbable Or Absorbable, For Pelvic Use
2
Product Code
OHG
Circumcision Tray
2
Product Code
PFJ
Catheter, Balloon, Dilation Of Cervical Canal Prior To Labor
2
Product Code
OHL
Pap Smear Kit
2
Product Code
OJF
Hysterectomy Kit
2
Product Code
PGK
Cannula, Injector, Uterine, Endometrial Biopsy
2
Product Code
PKN
Dilator, Cervical, Synthetic, Osmotic
2
Product Code
OKU
Emergency Obstetrical Kit
1
Product Code
OKV
Obstetrical Kit
2
Product Code
OKY
Cytology Kit
2
Product Code
OQY
Intrauterine Tamponade Balloon
2
Product Code
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
2
Product Code
PON
Catheter, Balloon, Dilation Of Cervical Canal
2
Product Code
PUA
Tenaculum, Uterine, Exempt
2
Product Code
PVR
D&C Tray
2
Product Code
PVX
Vaginal Examination Tray
2
Product Code
PWB
Fetal Head Elevator
2
Product Code
PWI
Instrumentation, Surgical Mesh, Urogynecologic, Transvaginal Repair Of Pelvic Organ Prolapse
2
Product Code
PWK
Instrumentation, Surgical Mesh, Urogynecologic, Transabdominal Repair Of Pelvic Organ Prolapse
2
Product Code
Obstetrical and Gynecological Therapeutic Devices
CFR Sub-Part
Physical Medicine Prosthetic Devices
CFR Sub-Part
Prosthetic Devices
CFR Sub-Part
Therapeutic Devices
CFR Sub-Part
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 4 February 2023 at 10:33 pm
OB
/
obstetrical-and-gynecological-surgical-devices
/
HIN
/
K113080
View Source
TUBALGATOR
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K113080
510(k) Type
Traditional
Applicant
MECTRA LABS, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
6/29/2012
Days to Decision
255 days
Submission Type
Statement
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Assisted Reproduction Devices
Cardiovascular Monitoring Devices
Cardiovascular Prosthetic Devices
Clinical Chemistry Test Systems
Diagnostic Devices
Miscellaneous
Obstetrical and Gynecological Diagnostic Devices
Obstetrical and Gynecological Monitoring Devices
Obstetrical and Gynecological Prosthetic Devices
Obstetrical and Gynecological Surgical Devices
HER
Pelvimeter, External
FHG
Bell, Circumcision
FHJ
Shield, Circumcision
HCY
Curette, Uterine
HCZ
Forceps, Surgical, Gynecological
HDA
Forceps, Obstetrical
HDB
Extractor, Vacuum, Fetal
HDC
Tenaculum, Uterine
HDD
Table, Obstetrical, Ac-Powered (And Accessories)
HDE
Hook, Fibroid, Gynecological
HDF
Speculum, Vaginal, Metal
HDG
Speculum, Vaginal, Metal, Fiberoptic
HDH
Needle, Cerclage, Gynecological
HDI
Hook, Destructive, Obstetrical
HDJ
Scissors, Umbilical
HDK
Scissors, Episiotomy
HDL
Retractor, Vaginal
HDM
Packer, Uterine
HDN
Dilator, Cervical, Expandable
HDP
Elevator, Uterine
HDQ
Dilator, Cervical, Fixed Size
HDY
Dilator, Cervical, Hygroscopic-Laminaria
HDZ
Knife, Cervical Cone
HFB
Forceps, Biopsy, Gynecological
HFG
Coagulator, Laparoscopic, Unipolar (And Accessories)
HFH
Coagulator, Hysteroscopic (And Accessories)
HFI
Coagulator, Culdoscopic (And Accessories)
HFW
Clamp, Umbilical
HFX
Clamp, Circumcision
HFZ
Craniotribe
HGA
Cranioclast
HGC
Clamp, Uterine
HGD
Applicator, Vaginal
HGE
Amniotome
HGI
Electrocautery, Gynecologic (And Accessories)
HHF
Remover, Intrauterine Device, Contraceptive, Hook-Type
HHG
Dilator, Cervical, Vibratory
HHM
Sound, Uterine
HHN
Cleidoclast
HHO
Screw, Fibroid, Gynecological
HHP
Table, Obstetrical, Manual (And Accessories)
HHR
Laser, Surgical, Gynecologic
HHT
Spatula, Cervical, Cytological
HIB
Speculum, Vaginal, Nonmetal
HIC
Speculum, Vaginal, Nonmetal, Fiberoptic
HIM
Electrocautery, Endoscopic And Accessories
HIN
Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)
K
14
2525
PK Lap Loop
K
13
0305
LINA BIPOLAR LOOP; STANDARD SIZE, LARGE SIZE, EXTRA LARGE SIZE
K
12
2983
KSEA BIPOLAR ELECTRODE
K
12
2605
PKS BILL
K
11
3080
TUBALGATOR
K
11
1751
VERSAPOINT II BIPOLAR ELECTROSURGERY GENERATOR, VERSAPOINT II 44MM ANGLED LOOP ELECTRODE, VERSAPOINT II FOOTSWITCH, VERS
K
11
1059
GYRUS ACMIL BIPOLARLAPROSCOPIC LOOP (PKS BILL)
K
99
0147
BIPOLAR FORCEPS, KLEPPINGER INSERT, MODEL #'S 8393.741,8393.771,8394.741,8394.771
K
97
1565
BICOAG COAGULATING FORCEPS
K
92
6517
ELMED LBC 50-P
Show All 16 Submissions
KNA
Instrument, Manual, Specialized Obstetric-Gynecologic
KNB
Instrument, Destructive, Fetal, Obstetric
KNC
Table, Obstetric (And Accessories)
KNF
Coagulator-Cutter, Endoscopic, Unipolar (And Accessories)
KOH
Instrument, Manual, General Obstetric-Gynecologic
LBX
Pelvimeter, Internal
LKF
Cannula, Manipulator/Injector, Uterine
LLW
Laser, Neodymium:Yag For Gynecologic Use
MDG
System, Intrafallopian Cannula
MLS
Labor And Delivery Kit
MLT
Pelvic Exam Kit
MOV
Catheters, Salpingography
MPU
Source, Chemiluminescent Light
NBZ
Clamp And Cutter, Umbilical
NMG
Forceps, Biopsy, Gynecological, Reprocessed
OHC
Obstetrical Vacuum Delivery Kit
PBQ
Fixation, Non-Absorbable Or Absorbable, For Pelvic Use
OHG
Circumcision Tray
PFJ
Catheter, Balloon, Dilation Of Cervical Canal Prior To Labor
OHL
Pap Smear Kit
OJF
Hysterectomy Kit
PGK
Cannula, Injector, Uterine, Endometrial Biopsy
PKN
Dilator, Cervical, Synthetic, Osmotic
OKU
Emergency Obstetrical Kit
OKV
Obstetrical Kit
OKY
Cytology Kit
OQY
Intrauterine Tamponade Balloon
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
PON
Catheter, Balloon, Dilation Of Cervical Canal
PUA
Tenaculum, Uterine, Exempt
PVR
D&C Tray
PVX
Vaginal Examination Tray
PWB
Fetal Head Elevator
PWI
Instrumentation, Surgical Mesh, Urogynecologic, Transvaginal Repair Of Pelvic Organ Prolapse
PWK
Instrumentation, Surgical Mesh, Urogynecologic, Transabdominal Repair Of Pelvic Organ Prolapse
Obstetrical and Gynecological Therapeutic Devices
Physical Medicine Prosthetic Devices
Prosthetic Devices
Therapeutic Devices
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OB
/
obstetrical-and-gynecological-surgical-devices
/
HIN
/
K113080
View Source
TUBALGATOR
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K113080
510(k) Type
Traditional
Applicant
MECTRA LABS, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
6/29/2012
Days to Decision
255 days
Submission Type
Statement