- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- Assisted Reproduction DevicesCFR Sub-Part
- Cardiovascular Monitoring DevicesCFR Sub-Part
- Cardiovascular Prosthetic DevicesCFR Sub-Part
- Clinical Chemistry Test SystemsCFR Sub-Part
- Diagnostic DevicesCFR Sub-Part
- MiscellaneousMiscellaneous
- Obstetrical and Gynecological Diagnostic DevicesCFR Sub-Part
- Obstetrical and Gynecological Monitoring DevicesCFR Sub-Part
- Obstetrical and Gynecological Prosthetic DevicesCFR Sub-Part
- Obstetrical and Gynecological Surgical DevicesCFR Sub-Part
- HERPelvimeter, External1Product Code
- FHGBell, Circumcision2Product Code
- FHJShield, Circumcision2Product Code
- HCYCurette, Uterine1Product Code
- HCZForceps, Surgical, Gynecological2Product Code
- HDAForceps, Obstetrical2Product Code
- HDBExtractor, Vacuum, Fetal2Product Code
- HDCTenaculum, Uterine2Product Code
- HDDTable, Obstetrical, Ac-Powered (And Accessories)2Product Code
- HDEHook, Fibroid, Gynecological1Product Code
- HDFSpeculum, Vaginal, Metal1Product Code
- HDGSpeculum, Vaginal, Metal, Fiberoptic1Product Code
- HDHNeedle, Cerclage, Gynecological1Product Code
- HDIHook, Destructive, Obstetrical2Product Code
- HDJScissors, Umbilical1Product Code
- HDKScissors, Episiotomy1Product Code
- HDLRetractor, Vaginal1Product Code
- HDMPacker, Uterine1Product Code
- HDNDilator, Cervical, Expandable3Product Code
- HDPElevator, Uterine2Product Code
- HDQDilator, Cervical, Fixed Size1Product Code
- HDYDilator, Cervical, Hygroscopic-Laminaria2Product Code
- HDZKnife, Cervical Cone2Product Code
- HFBForceps, Biopsy, Gynecological1Product Code
- HFGCoagulator, Laparoscopic, Unipolar (And Accessories)2Product Code
- HFHCoagulator, Hysteroscopic (And Accessories)2Product Code
- HFICoagulator, Culdoscopic (And Accessories)2Product Code
- HFWClamp, Umbilical2Product Code
- HFXClamp, Circumcision2Product Code
- HFZCraniotribe2Product Code
- HGACranioclast2Product Code
- HGCClamp, Uterine1Product Code
- HGDApplicator, Vaginal1Product Code
- HGEAmniotome1Product Code
- HGIElectrocautery, Gynecologic (And Accessories)2Product Code
- HHFRemover, Intrauterine Device, Contraceptive, Hook-Type1Product Code
- HHGDilator, Cervical, Vibratory3Product Code
- HHMSound, Uterine1Product Code
- HHNCleidoclast2Product Code
- HHOScrew, Fibroid, Gynecological2Product Code
- HHPTable, Obstetrical, Manual (And Accessories)2Product Code
- HHRLaser, Surgical, Gynecologic2Product Code
- HHTSpatula, Cervical, Cytological2Product Code
- HIBSpeculum, Vaginal, Nonmetal2Product Code
- HICSpeculum, Vaginal, Nonmetal, Fiberoptic2Product Code
- HIMElectrocautery, Endoscopic And Accessories2Product Code
- HINCoagulator-Cutter, Endoscopic, Bipolar (And Accessories)2Product Code
- KNAInstrument, Manual, Specialized Obstetric-Gynecologic2Product Code
- KNBInstrument, Destructive, Fetal, Obstetric2Product Code
- KNCTable, Obstetric (And Accessories)2Product Code
- KNFCoagulator-Cutter, Endoscopic, Unipolar (And Accessories)2Product Code
- KOHInstrument, Manual, General Obstetric-Gynecologic1Product Code
- LBXPelvimeter, Internal2Product Code
- LKFCannula, Manipulator/Injector, Uterine2Product Code
- LLWLaser, Neodymium:Yag For Gynecologic Use2Product Code
- MDGSystem, Intrafallopian Cannula2Product Code
- MLSLabor And Delivery Kit2Product Code
- MLTPelvic Exam Kit2Product Code
- MOVCatheters, Salpingography2Product Code
- MPUSource, Chemiluminescent Light2Product Code
- NBZClamp And Cutter, Umbilical2Product Code
- NMGForceps, Biopsy, Gynecological, Reprocessed2Product Code
- OHCObstetrical Vacuum Delivery Kit2Product Code
- PBQFixation, Non-Absorbable Or Absorbable, For Pelvic Use2Product Code
- OHGCircumcision Tray2Product Code
- PFJCatheter, Balloon, Dilation Of Cervical Canal Prior To Labor2Product Code
- OHLPap Smear Kit2Product Code
- OJFHysterectomy Kit2Product Code
- PGKCannula, Injector, Uterine, Endometrial Biopsy2Product Code
- PKNDilator, Cervical, Synthetic, Osmotic2Product Code
- OKUEmergency Obstetrical Kit1Product Code
- OKVObstetrical Kit2Product Code
- OKYCytology Kit2Product Code
- OQYIntrauterine Tamponade Balloon2Product Code
- PMUContainment System, Laparoscopic Power Morcellation, With Instrument Port2Product Code
- PONCatheter, Balloon, Dilation Of Cervical Canal2Product Code
- PUATenaculum, Uterine, Exempt2Product Code
- PVRD&C Tray2Product Code
- PVXVaginal Examination Tray2Product Code
- PWBFetal Head Elevator2Product Code
- PWIInstrumentation, Surgical Mesh, Urogynecologic, Transvaginal Repair Of Pelvic Organ Prolapse2Product Code
- PWKInstrumentation, Surgical Mesh, Urogynecologic, Transabdominal Repair Of Pelvic Organ Prolapse2Product Code
- Obstetrical and Gynecological Therapeutic DevicesCFR Sub-Part
- Physical Medicine Prosthetic DevicesCFR Sub-Part
- Prosthetic DevicesCFR Sub-Part
- Therapeutic DevicesCFR Sub-Part
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Clamp, Uterine
- Page Type
- Product Code
- Regulation Medical Specialty
- Obstetrical and Gynecological
- Review Panel
- Obstetrical and Gynecological
- Submission Type
- 510(K) Exempt
- Device Classification
- Class 1
- Regulation Number
- 884.4520
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Not Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 884.4520 Obstetric-gynecologic general manual instrument
§ 884.4520 Obstetric-gynecologic general manual instrument.
(a) Identification. An obstetric-gynecologic general manual instrument is one of a group of devices used to perform simple obstetric and gynecologic manipulative functions. This generic type of device consists of the following:
(1) An episiotomy scissors is a cutting instrument, with two opposed shearing blades, used for surgical incision of the vulvar orifice for obstetrical purposes.
(2) A fiberoptic metal vaginal speculum is a metal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.
(3) A metal vaginal speculum is a metal instrument used to expose the interior of the vagina.
(4) An umbilical scissors is a cutting instrument, with two opposed shearing blades, used to cut the umbilical cord.
(5) A uterine clamp is an instrument used to hold the uterus by compression.
(6) A uterine packer is an instrument used to introduce dressing into the uterus or vagina.
(7) A vaginal applicator is an instrument used to insert medication into the vagina.
(8) A vaginal retractor is an instrument used to maintain vaginal exposure by separating the edges of the vagina and holding back the tissue.
(9) A gynecological fibroid hook is an instrument used to exert traction upon a fibroid.
(10) A pelvimeter (external) is an instrument used to measure the external diameters of the pelvis.
(b) Classification. Class I (general controls). The devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.
[45 FR 12684, Feb. 26, 1980, as amended at 54 FR 25052, June 12, 1989; 66 FR 38809, July 25, 2001]