- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- Assisted Reproduction DevicesCFR Sub-Part
- MQENeedle, Assisted Reproduction2Product Code
- MQFCatheter, Assisted Reproduction2Product Code
- MQGAccessory, Assisted Reproduction2Product Code
- MQHMicrotools, Assisted Reproduction (Pipettes)2Product Code
- MQIMicrotool Fabrication, Assisted Reproduction2Product Code
- MQJMicromanipulators And Microinjectors, Assisted Reproduction2Product Code
- MQKLabware, Assisted Reproduction2Product Code
- MQLMedia, Reproductive2Product Code
- MRXSystem, Assisted Reproduction Laser2Product Code
- MTWSystem, Water, Reproduction, Assisted, And Purification2Product Code
- MTXMicroscope And Microscope Accessories, Reproduction, Assisted1Product Code
- NNBNeedle, Reproduction, Assisted, Reprocessed2Product Code
- PBHEmbryo Image Assessment System, Assisted Reproduction2Product Code
- OYOCulture, Intravaginal, Assisted Reproduction2Product Code
- PUBAccessory, Assisted Reproduction, Exempt2Product Code
- PUCMicrotools, Assisted Reproduction (Pipettes), Exempt2Product Code
- PUDLabware, Assisted Reproduction, Exempt2Product Code
- QKHAssisted Reproduction Laminar Flow Workstation2Product Code
- QKIMedia, Reproductive, Exempt2Product Code
- Cardiovascular Monitoring DevicesCFR Sub-Part
- Cardiovascular Prosthetic DevicesCFR Sub-Part
- Clinical Chemistry Test SystemsCFR Sub-Part
- Diagnostic DevicesCFR Sub-Part
- MiscellaneousMiscellaneous
- Obstetrical and Gynecological Diagnostic DevicesCFR Sub-Part
- Obstetrical and Gynecological Monitoring DevicesCFR Sub-Part
- Obstetrical and Gynecological Prosthetic DevicesCFR Sub-Part
- Obstetrical and Gynecological Surgical DevicesCFR Sub-Part
- Obstetrical and Gynecological Therapeutic DevicesCFR Sub-Part
- Physical Medicine Prosthetic DevicesCFR Sub-Part
- Prosthetic DevicesCFR Sub-Part
- Therapeutic DevicesCFR Sub-Part
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Labware, Assisted Reproduction, Exempt
- Page Type
- Product Code
- Definition
- This product code is the class II exempt counterpart of MQK, and was exempted, subject to the limitations of exemption, under the procedures established by the 21st Century Cures Act. This device type does not require premarket notification (510(k)) to market if it does not exceed the general limitations of exemption found in 21 CFR 884.9 and the specific limitations of exemption as stated in the “Physical State” field of this product code description.
- Physical State
- Exemption is limited to dishes and plates that are intended for general assisted reproduction technology procedures.
- Technical Method
- This product code is the class II exempt counterpart of MQK, and was exempted, subject to the limitations of exemption, under the procedures established by the 21st Century Cures Act. This device type does not require premarket notification (510(k)) to market if it does not exceed the general limitations of exemption found in 21 CFR 884.9 and the specific limitations of exemption as stated in the “Physical State” field of this product code description.
- Target Area
- This product code is the class II exempt counterpart of MQK, and was exempted, subject to the limitations of exemption, under the procedures established by the 21st Century Cures Act. This device type does not require premarket notification (510(k)) to market if it does not exceed the general limitations of exemption found in 21 CFR 884.9 and the specific limitations of exemption as stated in the “Physical State” field of this product code description.
- Regulation Medical Specialty
- Obstetrical and Gynecological
- Review Panel
- Obstetrical and Gynecological
- Submission Type
- 510(K) Exempt
- Device Classification
- Class 2
- Regulation Number
- 884.6160
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Not Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 884.6160 Assisted reproduction labware
§ 884.6160 Assisted reproduction labware.
(a) Identification. Assisted reproduction labware consists of laboratory equipment or supplies intended to prepare, store, manipulate, or transfer human gametes or embryos for in vitro fertilization (IVF), gamete intrafallopian transfer (GIFT), or other assisted reproduction procedures. These include syringes, IVF tissue culture dishes, IVF tissue culture plates, pipette tips, dishes, plates, and other vessels that come into physical contact with gametes, embryos or tissue culture media.
(b) Classification. Class II (special controls) (mouse embryo assay information, endotoxin testing, sterilization validation, design specifications, labeling requirements, and clinical testing). The device, when it is a dish or plate intended for general assisted reproduction technology procedures, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.
[45 FR 12684, Feb. 26, 1980, as amended at 84 FR 71816, Dec. 30, 2019]