Browse hierarchy: [Neurology (NE)](/submissions/NE) → [Subpart F — Neurological Therapeutic Devices](/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices) → [21 CFR 882.5892](/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/882.5892) → PKR — Non-Invasive Vagus Nerve Stimulator - Headache

# PKR · Non-Invasive Vagus Nerve Stimulator - Headache

_Neurology · 21 CFR 882.5892 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR

## Overview

- **Product Code:** PKR
- **Device Name:** Non-Invasive Vagus Nerve Stimulator - Headache
- **Regulation:** [21 CFR 882.5892](/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/882.5892)
- **Device Class:** 2
- **Review Panel:** [Neurology](/submissions/NE)

## Identification

An external vagal nerve stimulator for headache is a prescription device used to apply an electrical current to a patient's vagus nerve through electrodes placed on the skin for the treatment of headache.

## Classification Rationale

Class II (special controls). The special controls for this device are:

## Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) The technical parameters of the device, including waveform, output modes, maximum output voltage and current (with 500, 2,000, and 10,000 ohm loads), pulse duration, frequency, net charge (µC) per pulse, maximum phase charge at 500 ohms, maximum current density (mA/cm
2 , r.m.s.), maximum average current (mA), maximum average power density (W/cm2 ), and the type of impedance monitoring system shall be fully characterized through non-clinical performance testing.(2) Software verification, validation, and hazard analysis shall be performed.
(3) Biocompatibility evaluation of the patient-contacting components of the device shall be performed.
(4) The device shall be tested for electrical, thermal, and mechanical safety, and for electromagnetic compatibility (EMC).
(5) The labeling must include:
(i) Instructions for proper use of the device, including placement of the device on the patient; and
(ii) Instructions on care and cleaning of the device.

## Recent Cleared Devices (9 of 9)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K211856](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K211856.md) | gammaCore Sapphire | Electrocore, Inc. | Sep 10, 2021 | SESE |
| [K203546](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K203546.md) | gammaCore Sapphire | Electrocore, Inc. | Feb 12, 2021 | SESE |
| [K191830](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K191830.md) | gammaCore Sapphire | Electrocore, Inc. | Mar 26, 2020 | SESE |
| [K182369](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K182369.md) | gammaCore Sapphire | Electrocore, Inc. | Nov 27, 2018 | SESE |
| [K180538](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K180538.md) | gammaCore Sapphire | Electrocore, LLC | Mar 30, 2018 | SESE |
| [K173442](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K173442.md) | gammaCore-S | Electrocore, LLC | Jan 23, 2018 | SESE |
| [K172270](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K172270.md) | gammaCore-2 | Eletrocore, LLC | Dec 7, 2017 | SESE |
| [K171306](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/K171306.md) | gammaCore-S | Electrocore, LLC | May 30, 2017 | SESE |
| [DEN150048](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR/DEN150048.md) | gammaCore Non-invasive Vagus Nerve Stimulator | Electrocore, LLC | Apr 14, 2017 | DENG |

## Top Applicants

- Electrocore, Inc. — 4 clearances
- Electrocore, LLC — 4 clearances
- Eletrocore, LLC — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PKR)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).