Browse hierarchy: [Neurology (NE)](/submissions/NE) → [Subpart F — Neurological Therapeutic Devices](/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices) → [21 CFR 882.5891](/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/882.5891) → PCC — Stimulator, Nerve, Electrical, Transcutaneous, For Migraine

# PCC · Stimulator, Nerve, Electrical, Transcutaneous, For Migraine

_Neurology · 21 CFR 882.5891 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC

## Overview

- **Product Code:** PCC
- **Device Name:** Stimulator, Nerve, Electrical, Transcutaneous, For Migraine
- **Regulation:** [21 CFR 882.5891](/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/882.5891)
- **Device Class:** 2
- **Review Panel:** [Neurology](/submissions/NE)

## Identification

A transcutaneous electrical nerve stimulator to treat headache is a device used to apply an electrical current to a patient's cranium through electrodes placed on the skin.

## Classification Rationale

Class II (special controls). The special controls for this device are:

## Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) The patient-contacting components of the device must be demonstrated to be biocompatible.
(2) Appropriate analysis/testing must validate electromagnetic compatibility and electrical, mechanical, and thermal safety.
(3) The technical parameters of the device, including waveform, output modes, maximum output voltage and current (with 500, 2,000, and 10,000 ohm loads), pulse duration, frequency, net charge (µC) per pulse, maximum phase charge at 500 ohms, maximum current density (mA/cm
2 , r.m.s.), maximum average current (mA), maximum average power density (W/cm2 ), and the type of impedance monitoring system must be fully characterized.(4) Electrical performance, adhesive integrity, shelf life, reusability, and current distribution testing of the electrodes must be conducted.
(5) Appropriate software verification, validation, and hazard analysis must be performed.
(6) Clinical performance data must demonstrate that the device is safe and effective as a treatment for headache in the indicated patient population.
(7) Labeling must include the following:
(i) Appropriate contraindications such as not for use in subjects with an implanted metallic or electronic device in the head, a cardiac pacemaker, or an implanted or wearable defibrillator.
(ii) Appropriate warnings such as not to apply the device on the neck or chest, not to use the device in the presence of electronic monitoring equipment, not to use in the bath or shower, not to use while sleeping, not to use while driving, not to use while operating machinery.
(iii) Appropriate precautions such as the long-term effects of chronic use of the device are unknown.
(iv) A summary of the expected risks and benefits of using the device.
(v) A summary of the clinical performance data, including information on the patient population for which the device has and has not been demonstrated to be effective, and any adverse events and complications.
(vi) Information on how the device operates and the typical sensations experienced during treatment.
(vii) A detailed summary of the device technical parameters.
(viii) An expiration date/shelf life for the electrodes and the number of times they can be reused.
(ix) Disposal instructions.

In combination with the general controls of the Food Drug & Cosmetic Act, the Transcutaneous Electrical Nerve Stimulator to Treat Headache is subject to the following special controls:

## Recent Cleared Devices (18 of 18)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K254216](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K254216.md) | Enso for Migraine | Hinge Health, Inc. | Apr 16, 2026 | SESE |
| [K242719](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K242719.md) | ELEXIR 2.0 (ALLIVE3) | Nu Eyne Co., Ltd. | Nov 6, 2024 | SESE |
| [K234029](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K234029.md) | CEFALY Connected - OTC, CEFALY Connected - Rx | Cefaly Technology | Jul 18, 2024 | SESE |
| [K232749](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K232749.md) | DOOPANG | Ybrain, Inc. | Jun 11, 2024 | SESE |
| [K233751](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K233751.md) | Milieve (YPS-301BD) | Soterix Medical, Inc. | Jun 3, 2024 | SESE |
| [K230782](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K230782.md) | TENS device-HeadaTerm 2 (Model: YF-HT2) | Wat Medical Technology, Inc. | Feb 26, 2024 | SESE |
| [K212071](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K212071.md) | Cefaly Dual Enhanced with RFID - OTC, Cefaly Dual Enhanced with RFID - Rx, Cefaly Dual Connected - OTC, Cefaly Dual Connected - Rx | Cefaly Technology | Dec 13, 2022 | SESE |
| [K212106](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K212106.md) | Relivion | Neurolief , Ltd. | Aug 2, 2021 | SESE |
| [K211380](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K211380.md) | Elexir | Nu Eyne Co., Ltd. | Jul 30, 2021 | SESE |
| [K210364](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K210364.md) | Migraine Tens Digital  Pain  Reliever | Shenzhen Dongdixin Technology Co., Ltd. | Jun 17, 2021 | SESE |
| [K203419](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K203419.md) | Relivion | Neurolief , Ltd. | Feb 16, 2021 | SESE |
| [K201895](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K201895.md) | Cefaly Dual | Cefaly Technology | Sep 29, 2020 | SESE |
| [K192773](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K192773.md) | ALLIVE | Nu Eyne Co., Ltd. | Dec 6, 2019 | SESE |
| [K172450](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K172450.md) | TENS device-HeadaTerm, eEspress | Wat Medical Technology (Ningbo) Co., Ltd. | Sep 13, 2018 | SESE |
| [K173006](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K173006.md) | Cefaly Dual | Cefaly Technology | Nov 28, 2017 | SESE |
| [K171446](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K171446.md) | Cefaly Acute | Cefaly Technology | Sep 15, 2017 | SESE |
| [K160237](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/K160237.md) | Cefaly | Cefaly Technology | Mar 4, 2016 | SESE |
| [DEN120019](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC/DEN120019.md) | CEFALY | Stx-Med Sprl | Mar 11, 2014 | DENG |

## Top Applicants

- Cefaly Technology — 6 clearances
- Nu Eyne Co., Ltd. — 3 clearances
- Neurolief , Ltd. — 2 clearances
- Hinge Health, Inc. — 1 clearance
- Shenzhen Dongdixin Technology Co., Ltd. — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC](https://fda.innolitics.com/submissions/NE/subpart-f%E2%80%94neurological-therapeutic-devices/PCC)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com