K092371 · Advanced Neuromodulation Systems · GZB · Dec 23, 2009 · Neurology
Device Facts
Record ID
K092371
Device Name
SWIFT-LOCK ANCHOR, MODEL 1192
Applicant
Advanced Neuromodulation Systems
Product Code
GZB · Neurology
Decision Date
Dec 23, 2009
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.5880
Device Class
Class 2
Indications for Use
ANS Neurostimulation Systems are indicated for spinal cord stimulation (SCS) in the management of chronic pain of the trunk and limbs, either as the sole mitigating agent, or as an adjunct to other modes of therapy used in a multidisciplinary approach. The Swift-Lock™ anchor is intended to be an accessory to the leads component of ANS SCS systems functioning to secure the lead to the fascia or interspinous/supra-spinous ligament.
Device Story
Swift-Lock™ Anchor (Model 1192) is a mechanical accessory for ANS spinal cord stimulation (SCS) systems. Device functions to secure stimulation leads to patient fascia or interspinous/supra-spinous ligaments. Used by physicians during surgical implantation of SCS systems to prevent lead migration. Mechanical design provides stable fixation of lead components within the body.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Mechanical anchor device; designed for surgical fixation of SCS leads to fascia or ligaments. Non-active, implantable accessory.
Indications for Use
Indicated for patients requiring spinal cord stimulation (SCS) for management of chronic pain of the trunk and limbs. Used as sole therapy or adjunct in multidisciplinary approach.
Regulatory Classification
Identification
An implanted spinal cord stimulator for pain relief is a device that is used to stimulate electrically a patient's spinal cord to relieve severe intractable pain. The stimulator consists of an implanted receiver with electrodes that are placed on the patient's spinal cord and an external transmitter for transmitting the stimulating pulses across the patient's skin to the implanted receiver.
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird-like figure with three curved lines representing its body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the bird-like figure.
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Advanced Neuromodulation Systems c/o Ms. Penny Houston, MBA, MHL Regulatory Affairs Specialist 6901 Preston Road Plano, TX 75024
DEC 2 3 2009
Re: K092371
Trade/Device Name: Swift-Lock™ Anchor (Model 1192) Regulation Number: 21 CFR 882.5880 Regulation Name: Implanted Spinal Cord Stimulator for Pain Relief Regulatory Class: II Product Code: GZB Dated: December 9, 2009 Received: December 10, 2009
Dear Ms. Houston:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{1}------------------------------------------------
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/cdrh/mdr/ for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Malvina B. Eydelman, M.D.
Director Division of Ophthalmic, Neurological, and Ear, Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## 3. Statement for Indications for Use
Indications for Use Statement
K092371 510(k) Number (if known):
Device Name: Swift-Lock™ Anchor
Indications for Use:
ANS Neurostimulation Systems are indicated for spinal cord stimulation (SCS) in the management of chronic pain of the trunk and limbs, either as the sole mitigating agent, or as an adjunct to other modes of therapy used in a multidisciplinary approach.
The Swift-Lock™ anchor is intended to be an accessory to the leads component of ANS SCS systems functioning to secure the lead to the fascia or interspinous/supra-spinous ligament.
Prescription Use X (Per 21 CFR 801.109) Or
Over-The-Counter Use _
Concurrence of CDRH, Office of Device Evaluation (ODE)
Jeffrey Tay
__
(Division Sign-Off)
Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
510(k) Number K092371
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.