K982379 · Johnson & Johnson Professionals, Inc. · HCI · Dec 18, 1998 · Neurology
Device Facts
Record ID
K982379
Device Name
SUNDT SLIM-LINE ANEURYSM CLIP APPLIER
Applicant
Johnson & Johnson Professionals, Inc.
Product Code
HCI · Neurology
Decision Date
Dec 18, 1998
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.4175
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Sundt Slim-Line Aneurysm Clip Applier is designed for use only with Sundt Slim-Line Aneurysm Clips.
Device Story
The Sundt Slim-Line Aneurysm Clip Applier is a reusable, hand-held surgical instrument constructed of stainless steel. It is available in fixed-tip and hinged-tip configurations. The device features a handle grip with serrations, a two-piece spring, a shaft, and a v-grooved tip designed to grasp and place Sundt Slim-Line Aneurysm Clips. The shaft is angled and features a thin tip profile to enhance the surgeon's field of view during clip placement. The device is used by neurosurgeons in an operating room setting to facilitate the clipping of intracranial aneurysms.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Stainless steel reusable hand-held instrument; fixed or hinged tip configurations; v-grooved tip design; spring-loaded handle mechanism; angled shaft for visualization. Sterilization method not specified.
Indications for Use
Indicated for use by surgeons for the application of Sundt Slim-Line Aneurysm Clips during neurosurgical procedures.
Regulatory Classification
Identification
An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial aneurysm clips.
K211572 — Aesculap Slim Clip Applier · Aesculap, Inc. · Dec 13, 2021
K173271 — Aesculap Slim Clip Applier Forceps · Aesculap, Inc. · Nov 10, 2017
K984109 — AESCULAP AXIAL CLIP APPLIER · Aesculap, Inc. · Feb 12, 1999
K994191 — SPETZLER ROUND HANDLE APPLIERS, MODELS C-3753, C-3753T, C-3754, C-3754T · Nmt Medical, Inc. · Feb 8, 2000
K131500 — YASARGIL ANEURYSM CLIPS AND CLIP APPLIERS · Aesculap, Inc. · Jan 24, 2014
Submission Summary (Full Text)
{0}------------------------------------------------
# K982379
DEC 18 1998
# Exhibit I 510(k) Summary Sundt Slim-Line Aneurysm Clip Applier
Johnson & Johnson Professional, Inc. 325 Paramount Drive Raynham, Massachusetts 02767
## 1. Contact Person:
Janet G. Johnson Associate Regulatory Affairs Specialist (508) 828-3466
### 2. Device Information:
Proprietary Name: Common Name: Classification Name: Regulatory Class: Product Code:
Sundt Slim-Line Aneurysm Clip Applier Aneurysm Clip Applier Aneurysm Clip Applier Class II, per 21 §CFR 882.4175 84 HCl
### 3. Indications for Use:
The Sundt Slim-Line Aneurysm Clip Applier is designed for use only with Sundt Slim-Line Aneurysm Clips.
#### 4. Device Description:
The subject Sundt Slim-Line Aneurysm Clip Applier is a stainless steel reusable hand-held instrument that is available in two configurations a fixed tip applier and a hinged tip applier. All three appliers consist of a handle grip with serrations, a two-piece spring, a shaft, and a v-grooved shape tip for grasping the aneurysm clip. The fixed tip Sundt Slim-Line Aneurysm Clip Applier and the Sugita appliers are designed with shaft that angles down and a thin tip profile to provide the surgeon a greater field of view during clip placement.
#### 5. Substantial Equivalence:
The determination of substantial equivalence for the Sundt Slim-Line Aneurysm Clip Applier was based on a detailed device description, intended use, materials, design, sterilization, and packaging to the Aneurysm Clip Applier (K791764A) and the Sugita Aneurysm Clip Applier (K791978).
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized image of three human profiles facing right, stacked on top of each other. The profiles are black and are set against a white background. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the image.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
DEC 18 1998
Ms. Janet G. Johnson, RAC Associate Regulatory Affairs Specialist Johnson and Johnson Professional, Incorporated 325 Paramount Drive Raynham, Massachusetts 02767-0350
Re: K982379 Trade Name: Sundt Slim-Line Aneurysm Clip Applier Regulatory Class: II Product Code: HCI Dated: October 29, 1998 Received: October 30, 1998
Dear Ms. Johnson:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{2}------------------------------------------------
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely vours.
Sincerely yours,
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
K982379
510(k) Number (if known) Device Name
Sundt Slim-Line Aneurysm Clip Applier
# Indications For Use
The Sundt Slim-Line Aneurysm Clip Applier is designed for use only with Sundt Slim-Line Aneurysm Clips.
(Please do not write below this line - Continue on another page if necessary) Concurrence of CDRH, Office of Device Evaluation (ODE)
bcoole
(Division Sign-Off) Division of General Restorative Device 510(k) Number
Prescription Use X
(Per 21 CFR §801.109)
OR
Over-the-Counter Use_
(Optional Format 1-2-96)
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.