← Product Code [HBG](/submissions/NE/subpart-e%E2%80%94neurological-surgical-devices/HBG) · K022712

# HAND DRILL, MODEL 11-9901-7 (K022712)

_Medical Design, LLC · HBG · Nov 12, 2002 · Neurology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/NE/subpart-e%E2%80%94neurological-surgical-devices/HBG/K022712

## Device Facts

- **Applicant:** Medical Design, LLC
- **Product Code:** [HBG](/submissions/NE/subpart-e%E2%80%94neurological-surgical-devices/HBG.md)
- **Decision Date:** Nov 12, 2002
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 882.4300
- **Device Class:** Class 2
- **Review Panel:** Neurology
- **Attributes:** Therapeutic

## Indications for Use

The Medical Designs Hand Drill is intended for use in Neurosurgical procedures and for use with Medical Designs' Subdural Evacuating Port System (S.E.P.S.) Kit, Catalog # 11-9901. The Hand Drill is not intended for any use other than that indicated.

## Device Story

Manual cranial hand drill; used in neurosurgical procedures; designed for use with Subdural Evacuating Port System (S.E.P.S.) Kit. Device consists of ABS plastic housing, glass-filled nylon handle, ABS handle knob, lubricated aluminum gears, and 1/4" spring-loaded, chrome-plated steel 3-jaw chuck. Single-use disposable; gamma-sterilized. Operated by neurosurgeon to facilitate cranial access. No direct patient contact during intended use.

## Clinical Evidence

No clinical data; bench testing only.

## Technological Characteristics

Manual hand drill; materials: ABS plastic, glass-filled nylon, aluminum gears, chrome-plated steel 3-jaw chuck; 1/4" chuck size; single-use; gamma radiation sterilization.

## Regulatory Identification

Manual cranial drills, burrs, trephines, and their accessories are bone cutting and drilling instruments that are used without a power source on a patient's skull.

## Predicate Devices

- Integra NeuroSciences Camino Hand Drill - Model 030 ([K862160](/device/K862160.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

X 022712

Image /page/0/Picture/1 description: The image shows the logo for Medical Designs LLC. The logo is in black and white and features the words "MEDICAL DESIGNS" in large, bold letters. Above the letter "A" in "MEDICAL" is an image of a surgical instrument. Below the company name is the text "Surgical Instruments Designed by Doctors".

213 Sunset Drive Brandon, SD 57005 Phone: (605)376-6008 Fax: (605)335-1489 E-mail: axt1@worldnet.att.net

NOV 1 2 2002

# 510(k) Summary

#### 1. Submitter Information:

Medical Designs, LLC 213 Sunset Drive Brandon, South Dakota 57005 (605) 376-6008 (605) 335-1489 Fax e-mail: paxt(@medicaldesignsllc.com

Contact: Mr. Paul John Axt Preparation Date: August 13, 2002

#### 2. Trade Name:

Hand Drill (Catalog # 11-9901-7)

Common Name: Cranial hand drill

## Classification Name:

Drills, Burrs, Trephines & Accessories (Manual)

## Classification:

The Medical Designs hand drill is a Class II device (21 CFR 882.4300)

- 3. Predicate Device:
Integra NeuroSciences Camino Hand Drill - Model 030 (K862160)

#### 4. Performance Standards:

No applicable performance standards have been established by the FDA under Section 514 of the Food, Drug and Cosmetic Act

{1}------------------------------------------------

#### 5. Device Description:

The hand drill consists of a black ABS plastic housing, glass filled nylon handle and ABS plastic handle knob. The hand drill has lubricated aluminum gears and a ¼" spring loaded, chrome plated steel, 3-jaw chuck assembly.

The hand drill is a single-use disposable device. It is sterilized using gamma radiation.

#### 6. Intended Use:

The Medical Designs Hand Drill is intended for use in Neurosurgical procedures and for use with Medical Designs' Subdural Evacuating Port System (S.E.P.S.) Kit, Catalog # 11-9901.

The Hand Drill is not intended for any use other than that indicated.

#### 7. Biocompatibility:

The materials used to manufacture Medical Designs' hand drill are identical to the materials used to manufacture the predicate device. When used as intended, neither the Medical Designs hand drill nor the predicate device come in direct contact with the body or bodily fluids.

#### 8. Summary of Substantial Equivalence:

The Medical Designs hand drill has the same intended use as the Integra NeuroSciences Camino hand drill. Both are intended for use in Neurosurgery and Neurosurgical procedures.

The Medical Designs hand drill is made of the same materials and components as the predicate device and, therefore, does not raise new issues relating to the safety or effectiveness of its intended use.

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the top half of the circle. Inside the circle is an abstract image of an eagle with three lines representing its body.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

## NOV 12 2002

Medical Designs, LLC Paul John Axt Vice President of Operations 213 Sunset Drive Brandon, South Dakota 57005

Re: K022712

Trade/Device Name: Hand Drill, Model 11-9901-7 Regulation Number: 882.4300 Regulation Name: Drills, Burrs, Trephines and Accessories (Manual) Regulatory Class: Class II Product Code: HBG Dated: August 13, 2002 Received: August 14, 2002

Dear Mr. Axt:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

Page 2 – Mr. Paul John Axt

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours.

Sincerely yours,
*muriam C. Provost*

for Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

# Statement of Indications for Use

"The Medical Designs Hand Drill is intended for use in Neurosurgical procedures and for use with Medical Designs' Subdural Evacuating Port System Kit (S.E.P.S), Catalog # 11-9901."

"The Hand Drill is not intended for any use other than that indicated."

Miriam C. Provost

(Division Sign-Off) (Division of General, Restorative and Neurological Devices

510(k) Number_k022712

---

**Source:** [https://fda.innolitics.com/submissions/NE/subpart-e%E2%80%94neurological-surgical-devices/HBG/K022712](https://fda.innolitics.com/submissions/NE/subpart-e%E2%80%94neurological-surgical-devices/HBG/K022712)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
