K014060 · Microaire Surgical Instruments, Inc. · HBE · Mar 5, 2002 · Neurology
Device Facts
Record ID
K014060
Device Name
MICROAIRE 1000E SYSTEM
Applicant
Microaire Surgical Instruments, Inc.
Product Code
HBE · Neurology
Decision Date
Mar 5, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.4310
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The MicroAire® 1000E System is intended for use in surgical procedures requiring the need for cutting, sawing, drilling, reaming, wire driving, pinning, screw driving, decorticating, shaping and manipulation of bone and bone related tissue.
Device Story
MicroAire 1000E System is an electric surgical power system for bone manipulation. Components include electric power supply, power-connecting cables, foot/hand lever activation controls, modular/unitized handpieces, and head assemblies. System operates via electric motors providing variable speed/torque for surgical tasks. Used in OR settings by surgeons across various specialties (ENT, orthopedic, neuro, etc.). Provides mechanical power to attachments for cutting, drilling, and sawing bone. Benefits include precise bone manipulation during surgical procedures. Does not include integrated irrigation; stand-alone irrigation available separately.
Clinical Evidence
No clinical data. Substantial equivalence based on design, performance, and technological characteristics compared to the predicate device.
Technological Characteristics
Class I, Type BF electric power supply (50-60 Hz, 100-230 VAC). Modular/unitized handpieces with electric motors. Foot-controlled throttle mechanisms. Head assemblies for high/medium/low speed drills, oscillating/sagittal/reciprocating saws, and wire/pinning/reaming/drilling chucks. Meets UL, CSA, and IEC safety standards.
Indications for Use
Indicated for cutting, sawing, drilling, reaming, wire driving, pinning, screw driving, decorticating, shaping, and manipulation of bone and bone-related tissue in ENT, maxillofacial, neurological, oral, orthopedic, plastic, podiatric, and spinal surgery.
Regulatory Classification
Identification
Powered simple cranial drills, burrs, trephines, and their accessories are bone cutting and drilling instruments used on a patient's skull. The instruments are used with a power source but do not have a clutch mechanism to disengage the tip after penetrating the skull.
Predicate Devices
Stryker® HERMES-Ready™ Total Performance System (TPS™) (K991696)
Submission Summary (Full Text)
{0}------------------------------------------------
KO14060 1/2 5 2002 MAR
## X . 510(k) Summary
| Date: | December 1, 2001 |
|-----------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Submitted By: | MicroAire® Surgical Instruments<br>1641 Edlich Drive<br>Charlottesville, VA 22911 |
| Contact Person: | Carl Angles<br>Director of Quality and Regulatory Affairs |
| Telephone:<br>Facsimile: | 434-975-8000<br>434-975-4144 |
| Proprietary Name:<br>Common Name:<br>Classification Name: | MicroAire® 1000E System<br>Electric Surgical System for Cutting and Drilling<br>Powered simple cranial drills, burrs, trephines and<br>their accessories (21 CFR § 882.4310) |
The MicroAire® 1000E System is substantially equivalent to the Stryker® HERMES-Ready™ Total Performance System (TPS™), 510(k) number K991696, predicate device. Although the 1000E system does not integrate irrigation, joint shaving and endoscopy features, the intended use, design, energy, materials, performance, safety, effectiveness, labeling, biocompatibility, and applicable standards are substantially equivalent to the Stryker TPS.
The MicroAire® 1000E System is intended for use in surgical procedures requiring the need for cutting, sawing, drilling, reaming, wire driving, pinning, screw driving, decorticating, shaping and manipulation of bone and bone related tissue.
The MicroAire® 1000E System consists of an electric power supply, powerconnecting cable(s), a foot and/or hand lever power activation control, modular and unitized handpieces, modular head assemblies and accessories.
{1}------------------------------------------------
## KOLADGO 2/2
## Technological Characteristic Summary - 1000E v. TPS
Power Source: Both sources are Class I, Type BF, electrically powered and controlled devices (50-60 Hz, 100-230 VAC input), which meet the same basic voluntary safety standards (UL, CSA, IEC). However, the TPS system integrates an irrigator pump into the power console while the 1000E does not. MicroAire markets and sells a "stand-alone" irrigation system for those customers that utilize irrigation.
Electric Motors: Both systems contain modular and unitized handpieces that operate at different cycle, speed and/or torque parameters necessary for various surgical procedures.
Foot Control: Both systems utilize foot-controlling throttle mechanisms.
Electric Connecting Cable: Both systems use electric cables to connect the power supply with the handpieces.
Head Assemblies: Both systems have head configurations facilitating high, medium and low speed drills, oscillating, sagittal and reciprocating saws and wire, pinning, reaming and drilling chucks.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized image of an eagle with three lines representing its body and wings. The eagle is facing to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
5 2002 MAR
Mr. Carl Angles Director of Quality and Regulatory Affairs MicroAire Surgical Instruments 1641 Edlich Drive Charlottesville, VA 22911
Re: K014060
Trade/Device Name: MicroAire® 1000E System Regulation Number: 882.4310, 882.4360 Regulation Name: Powered simple cranial drills, burrs, trephines, and their accessories Electric cranial drill motor Regulatory Class: II Product Code: HBE, HBC Dated: December 7, 2001 Received: December 10, 2001
Dear Mr. Angles:
We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed your becament be device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for use stated in the encrosale) to regard ment date of the Medical Device Amendments, or to conimeres prior to may 20, 1978, the exactions of the Federal Food, Drug, devices that have been rocussion in avere approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The I va may, merelore, manot and include requirements for annual registration, listing of general controls provisions of ractice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it rr your device is classified (over a controls. Existing major regulations affecting your device can
may be subject to such additional controls. Existing major regulations of may be subject to sach additions, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean r lease oc advised that I DTT of local that your device complies with other requirements of the Act that I Dr Hab intatutes and regulations administered by other Federal agencies. You must or any I cacial stututes and regulances including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set Of It Far 8077, adoling (21 (QS) regulation (21 CFR Part 820); and if applicable. the electronic for all in the quality byticins (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
Page 2 - Mr. Carl Angles
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Miriam C. Provost
for Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Page 1
KO14060 510(k) Number (if Known): ____________________________________________________________________________________________________________________________________________________
Device Name:____MicroAire® 1000E System
Indications For Use:
The MicroAire® 1000E System is indicated for use in cutting, sawing, drilling, reaming, wire driving, pinning, screw driving, decorticating, shaping and manipulation of bone and other bone related tissue in a variety surgical procedures. The applications include ENT, maxilliofacial, neurological, oral, orthopedic, plastic, podiatric and spinal surgery.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
Over-The-Counter______________________________________________________________________________________________________________________________________________________________
Muriam C. Provost (Optional Format 1-2-96)
(Division Sign-Offi Division of General, Rentarative and Neurological . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OR
51 Number K014060
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.