K970865 · I.S.G. Technologies, Inc. · HAW · Jun 4, 1997 · Neurology
Device Facts
Record ID
K970865
Device Name
ISG FAMILY OF VIEWING WANDS
Applicant
I.S.G. Technologies, Inc.
Product Code
HAW · Neurology
Decision Date
Jun 4, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.4560
Device Class
Class 2
Indications for Use
The Family of Viewing Wands, (including cranial and spinal applications) is comprised of a medical workstation and an integrated position sensing probe, is intended to be used pre-operatively and intra-operatively to perform the following functions: - process and display pre-operatively radiographic images on a monitor; - provide intra-operative image information based on the position and orientation of a user directed probe; - allow for the optical integration and usage of different position sensing technologies (e.g. articulated arm, infrared freehand) and surgical probes (handheld pointers); - store/retrieve image data on computer access media (e.g. hard disks, archive media); and - transmit data over local area and wide area networks.
Device Story
Medical imaging workstation integrated with position-sensing user-directed probe; correlates pre-operative CT/MR images with intra-operative patient anatomy. System displays probe tip position and orientation on images in real-time. Used by surgeons pre-operatively for surgical planning (trajectory, entry point, instrumentation sizing) and intra-operatively for navigation in regions with complex anatomy, distorted landmarks, or proximity to critical structures. Benefits include improved surgical guidance in subcortical brain or spinal procedures. Supports various sensing technologies (articulated arm, infrared freehand) and handheld pointers. Data stored on computer media and transmitted via networks.
Clinical Evidence
No clinical data provided; substantial equivalence based on technological characteristics and intended use.
Technological Characteristics
Medical workstation with integrated position-sensing probe. Supports multiple sensing technologies including articulated arms and infrared freehand systems. Connectivity via local and wide area networks. Data storage on hard disks/archive media. Class II stereotactic instrument.
Indications for Use
Indicated for patients with space-occupying lesions or malformations (soft tissue/osseous) in the head, or patients requiring decompressive/reconstructive spinal surgery or having imaged space-occupying lesions/malformations in the spine. Contraindicated for patients suspected of Creutzfeld-Jakob’s disease if adequate instrument sterilization cannot be assured.
Regulatory Classification
Identification
A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system.
{0}
ISC
K970865
JUN - 4 1997
# 510(K) SUMMARY
## I. COMPANY & CONTACT PERSON
ISG TECHNOLOGIES, INC.
6509 Airport Road
Mississauga L4v-1S7
Ontario, Canada
## II. DEVICE NAME AND CLASSIFICATION
Family of Viewing Wands
Classification: Stereotactic Instrument (21 CFR 882.4560)
## III. DESCRIPTION OF DEVICE
The ISG Family of Viewing Wands is comprised of a medical imaging workstation that is integrated with a position-sensing user directed probe. This allows for the provision of information pertaining to the current position of the probe related to the surrounding anatomy by correlating pre-operative CT and/or MR imaging data with the intraoperative situation. Once a patient’s CT or MR images have been transferred to the workstation, the patient is correlated to that image dataset. The system then displays the orientation of the probe and the position of the tip on the corresponding image, updating the display in real-time as the probe is moved.
## IV. INTENDED USE
The Family of Viewing Wands, (including cranial and spinal applications) is comprised of a medical workstation and an integrated position sensing probe, is intended to be used pre-operatively and intra-operatively.
## V. SUBSTANTIAL EQUIVALENCE
The spinal application as described in this submission is a line (application) extension to the Family of Viewing Wands (K960714) and is substantially equivalent to other devices (Stealth Station - K954276) within the classification of diagnostic devices (21CFR 882.4560) that have been reviewed under the provisions of the Medical Device Amendments and are being marketed in interstate commerce.
COPYRIGHT 1997 ISG TECHNOLOGIES, INC.
ISG Technologies, Inc. 6509 Airport Road, Mississauga, Ontario, Canada M4V 1S7 • (905) 672-2100 1-800-724-5970 Fax (905) 672-2307
{1}
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration
9200 Corporate Boulevard
Rockville MD 20850
JUN - 4 1997
Mr. Charles Hall
Director, Clinical Development
ISG Technologies, Inc.
6509 Airport Road
Mississauga, Ontario
CANADA L4V 1S7
Re: K970865
Trade Name: ISG Family of Viewing Wands
Regulatory Class: II
Product Code: 84HAW
Dated: March 4, 1997
Received: March 10, 1997
Dear Mr. Hall:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{2}
Page 2 - Mr. Charles Hall
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours,
Thomas J. Callahan, Ph.D.
Director
Division of Cardiovascular, Respiratory, and Neurological Devices
Office of Device Evaluation
Center for Devices and Radiological Health
Enclosure
{3}
100 29 197 11:24
510(k) Number (if known): K970865
Device Name: ISG Family of Viewing Wands
## Indications For Use:
The Family of Viewing Wands, (including cranial and spinal applications) is comprised of a medical workstation and an integrated position sensing probe, is intended to be used pre-operatively and intra-operatively to perform the following functions:
- process and display pre-operatively radiographic images on a monitor;
- provide intra-operative image information based on the position and orientation of a user directed probe;
- allow for the optical integration and usage of different position sensing technologies (e.g. articulated arm, infrared freehand) and surgical probes (handheld pointers);
- store/retrieve image data on computer access media (e.g. hard disks, archive media); and
- transmit data over local area and wide area networks.
## Circumstances:
The Family of Viewing Wands is intended to be used pre-operatively:
- when more than one approach (e.g. entry point, trajectory, craniotomy size, screw placement) is being considered;
- when determining the size of any instrumentation;
continued...
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
[Signature]
(Division Sign-Off)
Division of Cardiovascular, Respiratory, and Neurological Devices
510(k) Number K970865
Prescription Use ☑ (Per 21 CFR 801.109)
OR
Over-The-Counter Use ☐
(Optional Format 1-2-96)
{4}
--/35 --2/3 --2/2/2.2 --29 37 11:24
...Circumstances, continued:
and intra-operatively, when:
- the target, trajectory, or approach is in a region with few anatomical landmarks (e.g. subcortical brain) or with complex anatomy (e.g. scoliosis, fractures, deformity);
- the target, trajectory, or approach is not entirely exposed (e.g. posterior approach for screw placement);
- the target, trajectory, or approach is in a region where the normal landmarks have been distorted either by disease (e.g. degenerative disease, osteophytes) or by previous surgery;
- the target, trajectory, or approach is in close proximity to critical structures (e.g. venous sinuses, air sinuses, spinal nerve roots or blood vessels) which must be avoided or negotiated; or
- the target’s delineation is important and will not move significantly during the approach (e.g. skull based tumors, sinus diseases, corpus callosotomies, spinal cord tumors).
**Disease or Conditions:**
The Family of Viewing Wands is indicated for patients who have space-occupying lesions or malformations (both soft tissue and osseous) in the head.
It is also indicated for patients who require decompressive or reconstructive surgery of the spine, or who have imaged space-occupying lesions or malformations in the spine.
The Family of Viewing Wands is contraindicated for patients suspected of having Creutzfeld-Jakob’s disease if adequate sterilization of the instrument cannot be assured.