K213065 · Guangzhou Easycess Medical Co.,Ltd · QJP · May 31, 2022 · Cardiovascular
Device Facts
Record ID
K213065
Device Name
Distal Access Catheter
Applicant
Guangzhou Easycess Medical Co.,Ltd
Product Code
QJP · Cardiovascular
Decision Date
May 31, 2022
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.1250
Device Class
Class 2
Intended Use
The Distal Access Catheter is indicated for general intravascular use, including the neuro and peripheral vasculature. It can be used to facilitate introduction of diagnostic agents or therapeutic devices. It is not intended for use in coronary arteries.
Device Story
Distal Access Catheter is a single-lumen, flexible, steam-shapeable catheter used to navigate neuro and peripheral vasculature. It facilitates delivery of diagnostic agents or therapeutic devices. Operated by physicians in clinical settings under fluoroscopic guidance. Device features coil and braid reinforcement for structural integrity and kink resistance; hydrophilic coating on distal 60 cm reduces friction. Radiopaque marker at distal tip enables visualization. Includes accessories: hemostatic valve, introducer sheath, and shaping mandrel. Physician shapes distal tip via steam, inserts catheter into vasculature, and uses luer fitting to attach accessories. Output is the successful delivery of diagnostic/therapeutic agents or devices to target sites. Benefits include improved access to tortuous vessels and procedural efficiency.
Clinical Evidence
Bench testing only. No clinical data. Performance verified via ISO 10555-1 standards, including tensile force, burst pressure, kink resistance, torque response, and simulated use in tortuous vessel models. Biocompatibility confirmed per ISO 10993 (cytotoxicity, sensitization, irritation, systemic toxicity, hemolysis, thrombogenicity, pyrogenicity).
Technological Characteristics
Single-lumen catheter; stainless-steel coil/braid reinforcement; PTFE inner liner; outer layers of PA, Pebax, PU. Platinum/iridium radiopaque marker. Hydrophilic coating. PC hub. Dimensions: 5F/6F. Sterilization: Ethylene Oxide. Mechanical sensing/actuation. No software/algorithm.
Indications for Use
Indicated for general intravascular use in neuro and peripheral vasculature to facilitate introduction of diagnostic agents or therapeutic devices. Not for use in coronary arteries.
Regulatory Classification
Identification
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
K131482 — SOFIA DISTAL ACCESS CATHETER · MicroVention, Inc. · Nov 22, 2013
K142014 — SOFIA DISTAL ACCESS CATHETER · MicroVention, Inc. · Oct 10, 2014
K150366 — SOFIA 6F Catheter · MicroVention, Inc. · Mar 27, 2015
K162565 — VIA 17 Microcatheter · Sequent Medical, Inc. · Feb 18, 2017
K050599 — TRACKER EXCEL -14 PRE-SHAPED MICROCATHETER · Boston Scientific Corp · Jun 3, 2005
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.
May 31, 2022
Guangzhou Easycess Medical Co., Ltd Xingcheng Liu Manager of Registration Affairs Department Room 701, Building B4, 11 Kaiyuan Avenue, Huangpu District, Guangzhou. 510530 China
#### Re: K213065
Trade/Device Name: Distal Access Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: QJP, DQY Dated: April 28, 2022 Received: May 5, 2022
#### Dear Xingcheng Liu:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part
{1}------------------------------------------------
801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Naira Muradyan, Ph.D. Assistant Director DHT5A: Division of Neurosurgical, Neurointerventional and Neurodiagnostic Devices OHT5: Office of Neurological and Physical Medicine Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known) K213065
Device Name Distal Access Catheter
Indications for Use (Describe)
The Distal Access Catheter is indicated for general intravascular use, including the neuro and peripheral vasculature. It can be used to facilitate introduction of diagnostic agents or therapeutic devices. It is not intended for use in coronary arteries.
| Type of Use (Select one or both, as applicable) |
|-------------------------------------------------|
| Option 1 |
| Option 2 |
X Prescription Use (Part 21 CFR 801 Subpart D)
__ Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
## 510(k) Summary K213065
## I. SUBMITTER
Guangzhou Easycess Medical Co., Ltd Room 701, Building B4, 11 Kaiyuan Avenue, Huangpu District, Guangzhou, China, 510530 Phone: 020-31603990 Fax: 020-31603675 Contact Person: Xingcheng Liu Date of Preparation: May 30th, 2022
## II. DEVICE
Name of Device: Distal Access Catheter Common or Usual Name: Distal Access Catheter Classification Name: Percutaneous catheter (21 CFR 870.1250) Regulatory Class: II Product Code: QJP, DQY
# III. PREDICATE DEVICE
Primary predicate device: SOFIA PLUS/Distal Access Catheter (K150366) Secondary predicate device: SOFIA Distal Access Catheter (K131482, K142014) These predicate devices have not been subject to a design-related recall. No reference devices were used in this submission.
## IV. DEVICE DESCRIPTION
The Distal Access Catheter consists of a catheter and accessories (hemostatic valve, introducer sheath, and a shaping mandrel). The catheter is a single-lumen, flexible catheter designed with coil and braid reinforcement. The distal segment is steamshapeable, and a hydrophilic coating is applied for navigation of the catheter through the vasculature. The radiopaque marker is located at the distal end of the catheter for visualization under fluoroscopy.
The catheter body is constructed with a stainless-steel coil (less 2 cm of the catheter length) over the inner lumen liner comprised of polytetrafluoroethylene (PTFE). To provide additional shaft support, a stainless-steel wire braiding has been added over the stainless-steel coil from the proximal end to distal end. A platinum/iridium alloy radiopaque marker band is located at the distal tip of the catheter. An outer layer of varying durometers and lengths of polyamide (PA), polyether block amide (Pebax) and polyurethane (PU) covers the entire catheter body from proximal to distal end, respectively.
A hub (PC) is attached to the proximal end of the catheter. A strain relief made from polyether block amide (Pebax) is placed at the proximal end of the catheter and distal
{4}------------------------------------------------
end of the hub. The hub-strain relief provides for the kink resistance for the proximal end. A luer fitting on the catheter hub is used for the attachment of accessories.
The outer surface of the catheter (distal 60 cm) is coated with a hydrophilic coating to reduce friction during navigation in the vasculature.
A shaping mandrel (stainless steel, 80 mm in length) is provided with the catheter to be used by the physician for tip shaping. An introducer sheath (PTFE) is included to facilitate the introduction of the catheter into guide catheters during clinical use. A hemostatic valve is used to connect to the proximal section of the catheter.
The Distal Access Catheter is provided sterile and for single use only. The catheter is placed in a dispenser tube (HDPE) and is placed on a packaging card (HDPE) that is provided in a sterile barrier PET/PE film and Tyvek pouch and placed in a carton box.
## V. INDICATIONS FOR USE
The Distal Access Catheter is indicated for general intravascular use, including the neuro and peripheral vasculature. It can be used to facilitate introduction of diagnostic agents or therapeutic devices. It is not intended for use in coronary arteries.
# VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH
## THE PREDICATE DEVICE
Technological Comparison:
| Device name | | SOFIA PLUS/Distal<br>Access Catheter<br>(K150366, Primary<br>predicate device) | SOFIA Distal Access<br>Catheter<br>(K131482, K142014,<br>Secondary predicate<br>device) | Distal Access Catheter<br>(K213065, Subject<br>device) |
|-------------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended Use | | The SOFIA PLUS<br>/Distal Access Catheters<br>are indicated for general<br>intravascular use,<br>including the neuro and<br>peripheral vasculature.<br>It can be used to<br>facilitate introduction of<br>diagnostic and<br>therapeutic agents. It is<br>not intended for use in<br>coronary arteries. | The SOFIA Distal<br>Access Catheter is<br>intended for general<br>intravascular use,<br>including the neuro<br>and peripheral<br>vasculature. It can be<br>used to facilitate the<br>introduction of<br>diagnostic and<br>therapeutic agents. It is<br>not intended for use in<br>coronary arteries. | The Distal Access<br>Catheter is indicated<br>for general<br>intravascular use,<br>including the neuro and<br>peripheral vasculature.<br>It can be used to<br>facilitate introduction<br>of diagnostic agents or<br>therapeutic devices. It<br>is not intended for use in<br>coronary arteries. |
| | Catheter<br>inner layer | PTFE, polyolefin<br>elastomer | PTFE, polyolefin<br>elastomer | PTFE |
| Material | Catheter<br>middle<br>layer | Stainless steel braid/coil | Stainless steel<br>braid/coil | Same |
| | Catheter<br>outer layer | Polyurethane elastomer,<br>polyether block amide<br>(Pebax) and polyamide | Polyurethane<br>elastomer, polyether<br>block amide (Pebax)<br>and polyamide | Same |
| | Marker | Platinum/Iridium | Platinum/Iridium | Same |
| | Hub | Nylon | Nylon | PC |
| Device name | | SOFIA PLUS/Distal Access Catheter<br>(K150366, Primary predicate device) | SOFIA Distal Access Catheter<br>(K131482, K142014, Secondary predicate device) | Distal Access Catheter<br>(K213065, Subject device) |
| Strain Relief | | Polyurethane | Polyurethane | Pebax |
| Introducer | | Pebax | Pebax | PTFE |
| Shaping Mandrel | | Stainless steel | Stainless steel | Same |
| Hemostatic Valve | | Not applicable | Not applicable | PC |
| Catheter Size | | 6F | 5F | 5F 6F |
| Inner Diameter (ID) | | 0.070 inch (1.78 mm) | 0.055 inch (1.4 mm) | 5F: 0.056" (1.42mm)<br>6F: 0.071" (1.80mm) |
| Outer Diameter (OD) | | 0.0825 inch (2.1 mm) | 0.068 inch (1.7 mm) | 5F: 0.068" (1.73mm)<br>6F: 0.083" (2.11mm) |
| Effective Length | | 115-135 cm | 115-125 cm | 115-135cm |
| Coating | | Hydrophilic coating<br>(Hydak®) | Hydrophilic coating<br>(Hydak®) | Hydrophilic coating (Polyamide) |
| Tip Configuration | | Steam shapeable by user | Steam shapeable by user | Same |
| Guidewire Compatibility | | 0.035 inch | 0.035 inch or 0.038 inch | 0.035 inch |
| Accessories | | Introducer sheath and shaping mandrel | Introducer sheath and shaping mandrel | Introducer sheath, shaping mandrel and hemostatic valve |
| Method of Supply | | Sterile and single use | Sterile and single use | Same |
| Sterilization Method | | Ethylene Oxide | Ethylene Oxide | Same |
| Packaging Configuration | | Catheter placed into a HDPE dispenser tube.<br>Dispenser tube, introducer and shaping mandrel placed on a polyethylene packaging card that is<br>inserted into a Tyvek® pouch. Pouch and IFU placed in bleached sulfate carton box. | Catheter placed into a HDPE dispenser tube.<br>Dispenser tube, introducer and shaping mandrel<br>placed on a polyethylene packaging card that is<br>inserted into a Tyvek® pouch. Pouch and IFU placed in bleached sulfate carton box. | Catheter placed into a HDPE dispenser tube.<br>Dispenser tube, introducer, shaping mandrel and hemostatic valve<br>placed on a polyethylene packaging card that is<br>inserted into a Tyvek/PE/PET pouch.<br>Pouch and IFU placed in bleached sulfate carton box. |
{5}------------------------------------------------
## VII. PERFORMANCE DATA
The following performance data were provided in support of the substantial equivalence determination.
#### . Bench Testing and Sterility
The bench testing of the Distal Access Catheter was performed using the applicable sections of the ISO 10555-1 international standard for sterile, single-use intravascular catheters. The testing demonstrates that the in vitro behavior of the device is well characterized within design specifications. The results of bench testing and sterility
{6}------------------------------------------------
evaluation are listed in the table below:
| Test | Specification | Conclusion |
|---------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------|
| Surface<br>Inspection | The external surface of the catheter shall be free<br>from extraneous matter. The external surface of<br>the catheter, including the distal end, shall be<br>free from process and surface defects which<br>could cause trauma to vessels during use. | The surface integrity is<br>suitable for intended clinical<br>use. |
| Surface<br>Contamination | The test article shall be free from surface<br>contaminants from uncured coating surface<br>particulates > 0.02 mm², embedded particulates.<br>The distal tip shall be smooth and tapered. PTFE<br>inner layer not delaminated. | The surface integrity is<br>suitable for intended clinical<br>use. |
| Dimensional<br>Verification | The device shall meet the specified dimensional<br>requirements, including catheter OD, catheter<br>ID, effective length, length of distal tip and total<br>length of accessories. | The device met the<br>dimensional and physical<br>specifications. |
| Distal Tip | The distal tip shall be smooth, rounded, tapered,<br>or similarly finished to minimize trauma to<br>vessels during use. | Distal tip is suitable for<br>intended clinical use. |
| Radio<br>Detectability | The tip of the catheter should be visible under<br>fluoroscopy. | Device radiopacity is suitable<br>for intended clinical use. |
| Corrosion<br>Resistance | Metallic components of the catheter intended for<br>fluid path contact shall show no signs of<br>corrosion. | Corrosion resistance is suitable<br>for intended clinical use and<br>met requirements of ISO<br>10555-1. |
| Peak Tensile<br>Force | 6F Catheter force at break ≥15N for distal<br>section and hub/catheter junction.<br>5F Catheter force at break ≥10N for distal<br>section and hub/catheter junction. | Peak tensile force is suitable<br>for intended clinical use and<br>met requirements of ISO<br>10555-1. |
| Fluid leakage<br>at > 46 psi | No liquid leakage from hub and catheter shaft at<br>46 psi for 30 seconds. | Device integrity is suitable for<br>intended clinical use and met<br>requirements of ISO 10555-1. |
| Air Leakage | No air leakage at hub into syringe when negative<br>pressure was applied for 15 seconds. | Device integrity is suitable for<br>intended clinical use and met<br>requirements of ISO 10555-1. |
| Guaging | The plane of the maximum diameter at the<br>opening of the female conical fitting shall lie<br>between the two limit planes of the gauge. | The device hub met the<br>requirements of ISO 80369-7. |
| Separation<br>Force | The mating parts separation force is greater than<br>35 N. | The device hub met the<br>requirements of ISO 80369-7. |
| Unscrewing<br>Torque | Test article luer remains attached after applying<br>an unscrewing torque not less than 0.02 N·m for<br>a minimum of 10 seconds. | The device hub met the<br>requirements of ISO 80369-7. |
| Stress<br>Cracking | No stress cracks on the test article hub. | The device hub met the<br>requirements of ISO 80369-7. |
| Ease<br>of<br>Assembly | Components fit together securely with no<br>resistance observed between the test article luer<br>and reference fitting. | The device hub met the<br>requirements of ISO 80369-7. |
| Resistance to<br>Overriding | Test article luer does not override reference<br>fitting threads. | The device hub met the<br>requirements of ISO 80369-7. |
| Particulate | The amount of particulate matter that comes off<br>the device during simulated use testing shall be<br>determined and compared to the predicate<br>device. | The amount and size of<br>particles from the subject<br>device was comparable to the<br>predicate device. |
| Static<br>Burst<br>Pressure | The catheter was tested to evaluate the burst<br>pressure under static conditions per ISO 10555-<br>1:2013(E) Annex F. | Device integrity is suitable for<br>intended clinical use and met<br>requirements of ISO 10555-1. |
| | | |
| Lubricity and<br>Durability | tester. The frictional force shall be equivalent to<br>the predicate device and be less than 0.3N. | coating cracking or separation,<br>and is equivalent to the<br>predicate device. |
| Equipment<br>Interface | The catheter shall be compatible with 0.035"<br>guidewire, ≥ 0.088" ID guide catheter/<br>introducer sheath, ≤ 0.027" OD microcatheters,<br>and common hemostatic valve. | The device is compatible with<br>the accessories as specified. |
| Tip<br>Shapeability | The distal tip should be steam shapeable and<br>equivalent to the predicate devices. | Shapeability of the distal tip<br>after steam shaping is<br>equivalent to predicate device. |
| Kink<br>Resistance | No kinks when wrapped around pin gauges of<br>clinical use relevant radii.<br>No kinks noted during simulated use testing.<br>Shall be equivalent to the predicate devices. | The device is resistant to<br>kinking around relevant radii<br>turns. |
| Simulated Use | The catheter should reach various target<br>locations in the tortuous vessel model; the<br>catheter could be delivered and retracted<br>smoothly with a 0.035" guidewire in the model;<br>no device damage or defects after simulated use. | Device performs as intended<br>under simulated use<br>conditions. |
| Torque<br>Response | The torque response of the catheter should be no<br>worse than the predicate device. | Device torque response is<br>equivalent to the predicate<br>device. |
| Torque<br>Strength | No catheter breakage after 50 rotations. | Device torque strength is<br>equivalent to the predicate<br>device. |
| Pushability/<br>Retractability | The pushability/retractability of the catheter in<br>the tortuous vessel model shall be not worse than<br>the predicate device. | Device pushability/<br>retractability is equivalent to<br>the predicate device. |
| Catheter<br>Stiffness | The catheter stiffness shall be equivalent to the<br>predicate devices. | The catheter stiffness is<br>equivalent to the predicate<br>device. |
| Catheter<br>Flexural<br>Fatigue | No flexural fatigue following repeated bending<br>during simulated use testing and repeated hoop<br>stress following pressure and air aspiration<br>testing. | The catheter flexural fatigue is<br>equivalent to the predicate<br>device. |
| Dynamic<br>Burst | The catheter shall not burst under dynamic<br>pressure of 300 psi for 30 seconds. | The device met the test<br>acceptance criteria. |
| Flow Rate | The catheter should withstand manual injection<br>of contrast media and saline at the clinically<br>relevant flow rates. | The device can withstand flow<br>rates suitable for intended<br>clinical use. |
| Ethylene<br>Oxide Residue | The residual amount of ethylene oxide in a<br>single package should not exceed 10µg/g. | Ethylene Oxide Residue met<br>the acceptance criteria per ISO<br>10993-7:2008. |
| Sterility | The product shall be sterile. | Sterility of the catheter met the<br>acceptance criteria per ISO<br>11135:2014. |
| Bacterial<br>Endotoxins | Endotoxin content shall not be greater than 2.15<br>EU/ kit. | Bacterial endotoxins<br>met<br>the acceptance criteria per USP<br><85/> |
| Biocompatibility Test | Result | Conclusion |
| Cytotoxicity Test (ISO 10993-5)<br>MTT Method, MEM with 10% FBS extract | The cell viability of 100%<br>test article extract was<br>95.5%. | Non-cytotoxic |
| Skin Sensitization Test (ISO 10993-10)<br>Guinea Pig Maximization Test, 0.9% Sodium<br>Chloride Injection Extract and Sesame Oil<br>Extract | The positive rate of the test<br>article was 0%. | No significant<br>evidence of skin<br>sensitization |
| Intracutaneous Reactivity Test (ISO 10993-<br>10)<br>0.9% Sodium Chloride Injection Extract and<br>Sesame Oil Extract | The final test article score<br>was calculated to be 0. | Non-irritant |
| Acute Systemic Toxicity Test (ISO 10993-11)<br>Intravenous 0.9% Sodium Chloride Injection<br>Extract and Sesame Oil Extract | Body weight data were<br>acceptable and equivalent<br>between the corresponding<br>test and control treatment<br>groups. | No significant<br>evidence of<br>systemic<br>toxicity |
| Acute Systemic Toxicity Test (ISO 10993-11)<br>Intraperitoneal Sesame Oil Extract | Body weight data were<br>acceptable and equivalent<br>between the corresponding<br>test and control treatment<br>groups. | No significant<br>evidence of<br>systemic<br>toxicity |
| Hemolytic Properties Test (ASTM F756)<br>Direct and Extract Contact Method Rabbit<br>Blood | The hemolysis index was<br>0.44% (direct contact) and<br>0.00 (indirect contact). | No influence on<br>hemolytic<br>properties |
| Partial Thromboplastin Time (PTT) Test (ISO<br>10993-4)<br>In vitro Human Blood | No significant differences<br>between the sample group<br>and the negative group. | No effect on<br>PTT |
| In Vivo Thrombogenicity Test (ISO 10993-4)<br>Non-anticoagulated venous implant (NAVI)<br>Model | No significant differences<br>between the test and control<br>articles. | Equivalent to<br>the control<br>article |
| Pyrogen Test (ISO 10993-11)<br>0.9% Sodium Chloride Injection Extract Rabbit | No rabbit shows an<br>individual rise in temperature<br>of 0.5 °C or more. | Non-pyrogenic |
| Complement Activity (C3a, SC5b-9) Test (ISO<br>10993-4)<br>In vitro Test | No significant difference<br>between the sample group<br>and negative control group. | Equivalent to<br>the negative<br>control group |
{7}------------------------------------------------
#### • Г Biocompatibility
The biocompatibility evaluation for the Distal Access Catheter was conducted in accordance with FDA's biocompatibility guidance, "Use of International Standard ISO 10993-1, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process"."
The biological tests were conducted in compliance with the Good Laboratory Practice (GLP) Regulation 21 CFR 58. The results of testing are listed in the table below:
{8}------------------------------------------------
## VIII. CONCLUSIONS
The data presented in this submission demonstrate the technological similarity and substantial equivalence of the Distal Access Catheter when compared with the predicate devices SOFIA PLUS/Distal Access Catheter(K150366) and SOFIA Distal Access Catheter (K131482, K142014).
The subject and predicate devices,
- . have the same indications for use,
- . use the same operating principle,
- . incorporate the same basic design,
- . are packaged and sterilized using similar materials and processes.
In summary, the Distal Access Catheter described in this submission is substantially equivalent to the predicate devices.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.