- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Cardiovascular Diagnostic DevicesCFR Sub-Part
- Cardiovascular Monitoring DevicesCFR Sub-Part
- Cardiovascular Therapeutic DevicesCFR Sub-Part
- Diagnostic DevicesCFR Sub-Part
- MiscellaneousMiscellaneous
- Neurological Diagnostic DevicesCFR Sub-Part
- GXWEchoencephalograph2Product Code
- GXXBlock, Test, Ultrasonic Scanner Calibration1Product Code
- GXYElectrode, Cutaneous2Product Code
- GXZElectrode, Needle2Product Code
- GYATester, Electrode/Lead, Electroencephalograph1Product Code
- GXSMonitor, Alpha2Product Code
- GWEStimulator, Photic, Evoked Response2Product Code
- GWFStimulator, Electrical, Evoked Response2Product Code
- GWGEndoscope, Neurological2Product Code
- GWIDiscriminator, Two-Point1Product Code
- GWJStimulator, Auditory, Evoked Response2Product Code
- GWKConditioner, Signal, Physiological2Product Code
- GWLAmplifier, Physiological Signal2Product Code
- GWMDevice, Monitoring, Intracranial Pressure2Product Code
- GWNNystagmograph2Product Code
- GWQFull-Montage Standard Electroencephalograph2Product Code
- GWRGenerator, Electroencephalograph Test Signal1Product Code
- GWSAnalyzer, Spectrum, Electroencephalogram Signal1Product Code
- GWWAtaxiagraph1Product Code
- GWXFork, Tuning1Product Code
- GWYPinwheel1Product Code
- GWZPercussor1Product Code
- GXBEsthesiometer1Product Code
- GYBMedia, Electroconductive2Product Code
- GYCElectrode, Cortical2Product Code
- GYDTransducer, Tremor2Product Code
- GYEEncephalogram Telemetry System2Product Code
- GZKElectrode, Nasopharyngeal2Product Code
- GZLElectrode, Depth2Product Code
- GZMAnalyzer, Rigidity2Product Code
- GZNRheoencephalograph3Product Code
- GZODevice, Galvanic Skin Response Measurement2Product Code
- GZPStimulator, Mechanical, Evoked Response2Product Code
- HCJDevice, Skin Potential Measurement2Product Code
- HCSDevice, Temperature Measurement, Direct Contact, Powered2Product Code
- JXEDevice, Nerve Conduction Velocity Measurement2Product Code
- JXFPlethysmograph, Ocular3Product Code
- LLNDevice, Vibration Threshold Measurement1Product Code
- LQWTest, Temperature Discrimination1Product Code
- NCGNeuropsychiatric Interpretative Electroencephalograph Assessment Aid2Product Code
- NTUEvoked Potential Stimulator, Thermal2Product Code
- OLTNon-Normalizing Quantitative Electroencephalograph Software2Product Code
- OLUNormalizing Quantitative Electroencephalograph Software2Product Code
- OLVStandard Polysomnograph With Electroencephalograph2Product Code
- OLWIndex-Generating Electroencephalograph Software2Product Code
- OLXSource Localization Software For Electroencephalograph Or Magnetoencephalograph2Product Code
- OLYMagnetoencephalograph2Product Code
- OLZAutomatic Event Detection Software For Polysomnograph With Electroencephalograph2Product Code
- OMAAmplitude-Integrated Electroencephalograph2Product Code
- OMBAutomatic Event Detection Software For Full-Montage Electroencephalograph2Product Code
- OMCReduced- Montage Standard Electroencephalograph2Product Code
- ORTBurst Suppression Detection Software For Electroencephalograph2Product Code
- PIWBrain Injury Adjunctive Interpretive Electroencephalograph Assessment Aid2Product Code
- PKQComputerized Cognitive Assessment Aid2Product Code
- PNAEvoked Photon Image Capture Device1Product Code
- POMComputerized Cognitive Assessment Aid For Concussion2Product Code
- POPCranial Motion Measurement Device2Product Code
- POSPhysiological Signal Based Seizure Monitoring System2Product Code
- PSPIntracranial Pressure & Temperature Monitoring Kit2Product Code
- PTBAtaxiagraph With Interpretive Software1Product Code
- PTYComputerized Cognitive Assessment Aid, Exempt2Product Code
- PVPNeurological Test Kit1Product Code
- QEABrain Injury Adjunctive Interpretive Oculomotor Assessment Aid2Product Code
- OPTInfrared Hematoma Detector2Product Code
- Neurological Surgical DevicesCFR Sub-Part
- Neurological Therapeutic DevicesCFR Sub-Part
- Physical Medicine Diagnostic DevicesCFR Sub-Part
- Physical Medicine Prosthetic DevicesCFR Sub-Part
- Physical Medicine Therapeutic DevicesCFR Sub-Part
- Surgical DevicesCFR Sub-Part
- Therapeutic DevicesCFR Sub-Part
- Obstetrical and GynecologicalReview Panel
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Computerized Cognitive Assessment Aid
- Page Type
- Product Code
- Definition
- The computerized cognitive assessment aid provides clinicians in a healthcare setting with objective measurements of cognitive function as a screening aid in the assessment of adults 55 years of age and older. This is done for the purpose of identifying a potential decline in cognitive function relative to baseline test performance of other age-normal adults, referring those adults for further testing where warranted, and monitoring changes in cognitive function over time
- Physical State
- Computer-administered battery of cognitive tests, computer keyboard, computer screen.
- Technical Method
- Uses a battery of objective cognitive tests delivered by computer software to determine an individual's current level of cognitive functioning.
- Target Area
- Brain
- Regulation Medical Specialty
- Neurology
- Review Panel
- Neurology
- Submission Type
- 510(K)
- Device Classification
- Class 2
- Regulation Number
- 882.1470
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Not Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 882.1470 Computerized cognitive assessment aid
§ 882.1470 Computerized cognitive assessment aid.
(a) Identification. The computerized cognitive assessment aid is a prescription device that uses an individual's score(s) on a battery of cognitive tasks to provide an interpretation of the current level of cognitive function. The computerized cognitive assessment aid is used only as an assessment aid to determine level of cognitive functioning for which there exists other valid methods of cognitive assessment and does not identify the presence or absence of clinical diagnoses. The computerized cognitive assessment aid is not intended as a stand-alone or adjunctive diagnostic device.
(b) Classification. Class II (special controls). Except when the computerized cognitive assessment aid is intended for diagnostic assessment of specific diseases or conditions and relies on inputs from visual cues, auditory cues, and/or functional use of the hand, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 882.9. The special control(s) for this device are:
(1) The technical parameters of the device's hardware and software must be fully characterized and be accompanied by appropriate non-clinical testing:
(i) Hardware specifications must be provided. Appropriate verification, validation, and hazard analysis must be performed.
(ii) Software, including any proprietary algorithm(s) used by the device to arrive at its interpretation of the patient's cognitive function, must be described in detail in the software requirements specification (SRS) and software design specification (SDS). Appropriate software verification, validation, and hazard analysis must be performed.
(2) The device must be designed and tested for electrical safety.
(3) The labeling must include:
(i) A summary of any testing conducted to demonstrate how the device functions as an interpretation of the current level of cognitive function. The summary of testing must include the following, if available: Any expected or observed adverse events and complications; any performance measurements including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) per the devices intended use; a description of the repeatability of measurements; a description of how the cut-off values for categorization of measurements were determined; and a description of the construct validity of the device.
(ii) A warning that the device does not identify the presence or absence of clinical diagnoses.
(iii) A warning that the device is not a stand-alone diagnostic.
(iv) The intended use population and the intended use environment.
(v) Any instructions technicians must convey to patients regarding the administration of the test and collection of cognitive test data.
[80 FR 49138, Aug. 17, 2015, as amended at 84 FR 71815, Dec. 30, 2019]