DISSECTRON PORTABLE UNIT

K972612 · Satelec · LBK · Oct 8, 1997 · NE

Device Facts

Record IDK972612
Device NameDISSECTRON PORTABLE UNIT
ApplicantSatelec
Product CodeLBK · NE
Decision DateOct 8, 1997
DecisionSESE
Submission TypeTraditional
Device ClassClass U
AttributesTherapeutic

Indications for Use

The intended use for the DISSECTRON device, as with the previously cleared devices, is for the successful fragmentation, emulsification and aspiration of soft tissue of various extirpation of any tumor in the central nervous system, inclusive of intracranial tumors, brain stem tumors, and spinal cord tumors, and neuro-acoustic tumors, and not necessarily limited to the following: Astrocytoma, Cerebellopontine anglo tumors, Cervico-facial tumors, Metastases, Pituitary adenoma, Acoustic neurimoma, Meningioma, Glioma, Craniopharynglomas, Deep-seated cerebral tumors. The DISSECTRON device is not intended for use in the following applications: any type of cardiac surgery, suction lipectomy, orthopedics.

Device Story

DISSECTRON is a portable, tabletop ultrasonic surgical aspirator for neurosurgery. Device uses ultrasonic longitudinal vibrations (23-35 kHz, 120-300um amplitude) via a titanium sonotrode to fragment and emulsify soft tissue while preserving blood vessels and nerves. System integrates ultrasonic fragmentation, irrigation (sterile saline), and suction (650 hPa vacuum). Components include base console, electrostrictive handpiece, and footswitch. Surgeon operates device in surgical suite using touch screen controls and footswitches to manage power, irrigation, and suction. Emulsified tissue is transported through hollow sonotrode to a collection bottle. Device enables precise tissue dissection with reduced blood loss and surrounding tissue damage.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Ultrasonic surgical aspirator; piezoelectric transducer; titanium sonotrode; operating frequency 23-35 kHz; oscillation amplitude 120-300um; vacuum range 650 hPa; tabletop console with microprocessor control; touch screen interface; footswitch control; sterile saline irrigation system.

Indications for Use

Indicated for fragmentation, emulsification, and aspiration of soft tissue in the neurosurgery field, specifically for the extirpation of central nervous system tumors including intracranial, brain stem, spinal cord, and neuro-acoustic tumors. Contraindicated for cardiac surgery, suction lipectomy, and orthopedics.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ OCT - 8 1997 Regulatory Affairs K972612 ## SMDA Summary of Safety and Effectiveness - "510(k) Summary" 9. - A. Submittor Information SATELEC Medical Z.I. due Phare, BP 215 Avenue Gustave Eiffel 33708 Merignac Cedex FRANCE 011-33-5-56-34-06-07 Telephone: Pascal Dupeyron Contact Person: July 11, 1997 Date Prepared: - B. Device Identification Common/Usual Name Proprietary Name: Ultrasonic Surgical Aspirator DISSECTRON - C. Identification of Predicate Device(s) The DISSECTRON is substantially equivalent to the following previously cleared and currently marketing devices: > Cooper Cavitron CUSA 200M (K864943) Sharplan 4300/4310 (K883091) Clinical Technology BOVIE (K855138A) ## D. Device Description The DISSECTRON is an ultrasonically vibrating hand-held surgical aspirator designed to precisely fragment and emulsify unwanted neurosurgical tissue, layer by layer, with preservation of major blood vessels, nerves, and elastic fibers. The DISSECTRON's selective effect on tissue is the result of three combined factors: - · Ultrasonic fragmentation, - · Irrigation, and, - · Suction. The DISSECTRON's principle of operation is tissular fragmentation which is achieved through uitrasonic longitudinal vibrations at an oscillation amplitude varying from 120 to 300um, at an operating frequency comprised between 23 and 35 kHz at the tip of the handpiece. The ultrasonic power is transmitted via a piezoelectric transducer, housed in the handpiece, which extends into a titanium sonotrode which is in direct contact with the tissue. It is possible to precisely dissect tissue with less surrounding tissue invasion and blood loss with DISSECTRON. {2}------------------------------------------------ Simultaneous irrigation is provided to the distal end of the tip. Sterile saline is routed from the drip holder to the control unit to the tip of the electrostrictive handpiece. A vacuum pump aspirates emulsified tissue in the pressure range of 650 hPa. Irrigating fluid and fragmented tissue particles are continuously aspirated through the distal end of the hollow titanium sonotrode (tip) and transported, via disposable tubing, to a collection bottle ("receptacle"). The DISSECTRON, a compact, portable, tabletop ultrasonic surgical aspirator installed in the surgical suite within the user's reach, consists of three primary components: - . the base console, - the hand-piece unit, (with 2 sonotrode dedicated extensions, and, . - the control pedal (footswitch). . The base console is controlled by a microprocessor and provides various indicators and controls designed to lead the operator through the sequential procedures needed for safe operation. Touch screen controls and displays provide the surgeon with a user friendly device. The lightweight electrostrictive handpiece is equipped with a titanium sonotrode, which acts as an ultrasonic transmitter, and is fitted with central suction and concentric irrigation. The foot pedal has two footswitches, a right switch, and a left switch, respectively, to control the Suction, Irrigation, and Ultrasound power. ## E. Substantial Equivalence The technical characteristics are almost identical to those of Cooper Cavitron CUSA 200 M. the Sharplan 4300/4310, and the Clinical Technology BOVIE previously cleared predicate devices. Refer to Table A for a comparison of these predicate devices. Differences that exist between these devices relating to technical specifications, materials, physical appearance, and control systems, do not affect the relative safety or effectiveness of the DISSECTRON device. The intended use for the DISSECTRON device, as with the previously cleared devices, is for the successful fragmentation, emulsification and aspiration of soft tissue of various extirpation of any tumor in the central nervous system, inclusive of intracranial tumors, brain stem tumors, and spinal cord tumors, and neuro-acoustic tumors, and not necessarily limited to the following: - · Astrocytoma - · Cerebellopontine anglo tumors - · Cervico-facial tumors - · Metastases - · Pituitary adenoma - · Acoustic neurimoma - · Meningioma - · Glioma - · Craniopharynglomas - Deep-seated cerebral tumors {3}------------------------------------------------ The DISSECTRON device is not intended for use in the following applications: . - any type of cardiac surgery, - · suction lipectomy, - orthopedics ) : ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ : : {4}------------------------------------------------ Image /page/3/Picture/2 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features the department's name in a circular arrangement around a symbol. The symbol is a stylized image of a human figure, with three profiles merging into one, representing health and human services. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20856 OCT - 8 1997 Ms. Jacqueline E. Masse Senior Consultant Interactive Consulting, Inc. for Satelec Medical 70 Walnut Street Wellesley, Massachusetts 02181 Re : K972612 Trade Name: DISSECTRON Portable Unit Requlatory Class: Unclassified Product Code: 84LBK Dated: July 11, 1997 Received: July 14, 1997 Dear Ms. Masse: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual reqistration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major requlations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any {5}------------------------------------------------ Page 2 - Ms. Jacqueline E. Masse obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or requlations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the requlation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597. Sincerely yours, Thomas J. Callahan Thomas J. Callahan Ph. D Director Division of Cardiovascular, Respiratory, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {6}------------------------------------------------ 510(k) Number (if known): K972612 Device Name: DISSECTRON Portable Unit Indications For Use: Fragmentation, emulsification and aspiration of soft tissue in the neurosurgery field. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Thomas J. Callahan (Division Sign-Off) Division of Cardiovascular, Respiratory, and Neurological Devices 510(k) Number R972672 Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter Use (Optional Format 1-2-96)
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...