SAS INFLUENZA A TEST
Device Facts
| Record ID | K041441 |
|---|---|
| Device Name | SAS INFLUENZA A TEST |
| Applicant | Sa Scientific, Inc. |
| Product Code | PSZ · Microbiology |
| Decision Date | Jul 22, 2004 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 866.3328 |
| Device Class | Class 2 |
| Attributes | Pediatric |
Intended Use
The BinaxNOW® Influenza A & B Test is an in vitro immunochromatographic assay for the qualitative detection of influenza A and B nucleoprotein antigens in nasopharyngeal (NP) swab and nasal wash/aspirate specimens. It is intended to aid in the rapid differential diagnosis of influenza A and B viral infections. Negative test results should be confirmed by cell culture. Caution: Assay sensitivity was determined primarily using archived specimens. Users may wish to establish the sensitivity of this test on fresh samples.
Device Story
The SAS™ Influenza A Test is a rapid, lateral-flow immunochromatographic assay used by healthcare professionals in clinical settings. It detects Influenza Type A viral nucleoproteins in nasal wash or aspirate specimens. The process involves extracting nucleoproteins from the sample, which then migrates via capillary action through a membrane containing gold-conjugated antibodies. If Influenza A antigens are present, a 'whole sandwich' immuno-complex forms, resulting in a visible pink line in the specimen zone. A procedural control line appears regardless of antigen presence. The test provides qualitative results to assist clinicians in the presumptive diagnosis of Influenza A, though negative results must be confirmed by culture. It does not detect Influenza B or C.
Clinical Evidence
Clinical evidence includes retrospective and prospective studies. Retrospective study (n=306 for Flu A, n=303 for Flu B) compared device to predicate, showing 100% sensitivity/96% specificity for Flu A and 93% sensitivity/97% specificity for Flu B. Prospective multi-center study (n=373) compared device to cell culture, showing 80% sensitivity/93% specificity for Flu A and 65% sensitivity/97% specificity for Flu B. Additional prospective study (n=114) compared device to culture/DFA, showing 75% sensitivity/100% specificity for Flu A and 50% sensitivity/100% specificity for Flu B. Precision study (n=250) showed 97% agreement across sites, operators, and days.
Technological Characteristics
Lateral-flow immunochromatographic assay. Utilizes monoclonal antibodies specific to Influenza Type A nucleoproteins conjugated to gold particles on a membrane. Includes internal procedural control line. Manual, point-of-care diagnostic format. No electronic components or software.
Indications for Use
Indicated for symptomatic patients, including pediatric (<18 years) and adult (≥18 years) populations, for the qualitative detection of influenza A and B nucleoprotein antigens in nasopharyngeal swabs and nasal wash/aspirate specimens. Prescription use only.
Regulatory Classification
Identification
An influenza virus antigen detection test system is a device intended for the qualitative detection of influenza viral antigens directly from clinical specimens in patients with signs and symptoms of respiratory infection. The test aids in the diagnosis of influenza infection and provides epidemiological information on influenza. Due to the propensity of the virus to mutate, new strains emerge over time which may potentially affect the performance of these devices. Because influenza is highly contagious and may lead to an acute respiratory tract infection causing severe illness and even death, the accuracy of these devices has serious public health implications.
Special Controls
*Classification.* Class II (special controls). The special controls for this device are:(1) The device's sensitivity and specificity performance characteristics or positive percent agreement and negative percent agreement, for each specimen type claimed in the intended use of the device, must meet one of the following two minimum clinical performance criteria: (i) For devices evaluated as compared to an FDA-cleared nucleic acid based-test or other currently appropriate and FDA accepted comparator method other than correctly performed viral culture method: (A) The positive percent agreement estimate for the device when testing for influenza A and influenza B must be at the point estimate of at least 80 percent with a lower bound of the 95 percent confidence interval that is greater than or equal to 70 percent. (B) The negative percent agreement estimate for the device when testing for influenza A and influenza B must be at the point estimate of at least 95 percent with a lower bound of the 95 percent confidence interval that is greater than or equal to 90 percent. (ii) For devices evaluated as compared to correctly performed viral culture method as the comparator method: (A) The sensitivity estimate for the device when testing for influenza A must be at the point estimate of at least 90 percent with a lower bound of the 95 percent confidence interval that is greater than or equal to 80 percent. The sensitivity estimate for the device when testing for influenza B must be at the point estimate of at least 80 percent with a lower bound of the 95 percent confidence interval that is greater than or equal to 70 percent. (B) The specificity estimate for the device when testing for influenza A and influenza B must be at the point estimate of at least 95 percent with a lower bound of the 95 percent confidence interval that is greater than or equal to 90 percent. (2) When performing testing to demonstrate the device meets the requirements in paragraph (b)(1) of this section, a currently appropriate and FDA accepted comparator method must be used to establish assay performance in clinical studies. (3) Annual analytical reactivity testing of the device must be performed with contemporary influenza strains. This annual analytical reactivity testing must meet the following criteria: (i) The appropriate strains to be tested will be identified by FDA in consultation with the Centers for Disease Control and Prevention (CDC) and sourced from CDC or an FDA-designated source. If the annual strains are not available from CDC, FDA will identify an alternative source for obtaining the requisite strains. (ii) The testing must be conducted according to a standardized protocol considered and determined by FDA to be acceptable and appropriate. (iii) By July 31 of each calendar year, the results of the last 3 years of annual analytical reactivity testing must be included as part of the device's labeling. If a device has not been on the market long enough for 3 years of annual analytical reactivity testing to have been conducted since the device received marketing authorization from FDA, then the results of every annual analytical reactivity testing since the device received marketing authorization from FDA must be included. The results must be presented as part of the device's labeling in a tabular format, which includes the detailed information for each virus tested as described in the certificate of authentication, either by: (A) Placing the results directly in the device's § 809.10(b) of this chapter compliant labeling that physically accompanies the device in a separate section of the labeling where the analytical reactivity testing data can be found; or (B) In the device's label or in other labeling that physically accompanies the device, prominently providing a hyperlink to the manufacturer's public Web site where the analytical reactivity testing data can be found. The manufacturer's home page, as well as the primary part of the manufacturer's Web site that discusses the device, must provide a prominently placed hyperlink to the Web page containing this information and must allow unrestricted viewing access. (4) If one of the actions listed at section 564(b)(1)(A)-(D) of the Federal Food, Drug, and Cosmetic Act occurs with respect to an influenza viral strain, or if the Secretary of Health and Human Services (HHS) determines, under section 319(a) of the Public Health Service Act, that a disease or disorder presents a public health emergency, or that a public health emergency otherwise exists, with respect to an influenza viral strain: (i) Within 30 days from the date that FDA notifies manufacturers that characterized viral samples are available for test evaluation, the manufacturer must have testing performed on the device with those viral samples in accordance with a standardized protocol considered and determined by FDA to be acceptable and appropriate. The procedure and location of testing may depend on the nature of the emerging virus. (ii) Within 60 days from the date that FDA notifies manufacturers that characterized viral samples are available for test evaluation and continuing until 3 years from that date, the results of the influenza emergency analytical reactivity testing, including the detailed information for the virus tested as described in the certificate of authentication, must be included as part of the device's labeling in a tabular format, either by: (A) Placing the results directly in the device's § 809.10(b) of this chapter compliant labeling that physically accompanies the device in a separate section of the labeling where analytical reactivity testing data can be found, but separate from the annual analytical reactivity testing results; or (B) In a section of the device's label or in other labeling that physically accompanies the device, prominently providing a hyperlink to the manufacturer's public Web site where the analytical reactivity testing data can be found. The manufacturer's home page, as well as the primary part of the manufacturer's Web site that discusses the device, must provide a prominently placed hyperlink to the Web page containing this information and must allow unrestricted viewing access.
Predicate Devices
- FLU OIA A/B Test Kit (K021469)
Related Devices
- K080380 — SAS INFLUENZA A & B TEST · Sa Scientific, Inc. · Jul 23, 2009
- K100227 — SAS FLUALERT A&B, SAS INFLUENZA A TEST · Sa Scientific, Inc. · Feb 23, 2010
- K132352 — SAS FLUALERT A & B, SAS INFLUENZA A TEST · Sa Scientific , Ltd. · Aug 22, 2013