PQA · Vaginitis And Bacterial Vaginosis Nucleic Acid Detection System

Microbiology · 21 CFR 866.3975 · Class 2

Overview

Product CodePQA
Device NameVaginitis And Bacterial Vaginosis Nucleic Acid Detection System
Regulation21 CFR 866.3975
Device ClassClass 2
Review PanelMicrobiology

Identification

A device that detects nucleic acid sequences from microorganisms associated with vaginitis and bacterial vaginosis is a qualitative in vitro diagnostic device intended for the detection of microbial nucleic acid sequences in vaginal specimens collected from patients with signs and symptoms of vaginitis or bacterial vaginosis. This device is intended to aid in the diagnosis of vaginitis or bacterial vaginosis when used in conjunction with clinical signs and symptoms and other laboratory findings.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) Design verification and validation must include: (i) Documentation with a detailed device description of device components; ancillary reagents required but not provided; and explanation of the methodology including primer/probe sequence, design, and rationale for sequence selection. (ii) Documentation with information that demonstrates the performance characteristics of the device, including: (A) Limit of Detection; (B) Precision (reproductivity); (C) Analytical specificity; (D) Analytical reactivity (inclusivity); (E) Specimen stability; and (F) Effects of interfering substances. (iii) Detailed documentation from a prospective clinical study. As appropriate to the intended use, the prospective clinical study must be performed on an appropriate study population, including women of various ages and ethnicities. The prospective clinical study must compare the device performance to results obtained from well-accepted comparator methods. (iv) Detailed documentation for device software, including software applications and hardware-based devices that incorporate software. (2) The labeling required under § 809.10(b) of this chapter must include: (i) A detailed explanation of the interpretation of results and acceptance criteria; (ii) For devices with an intended use that includes detection of nucleic acid sequences from bacteria associated with bacterial vaginosis, clinical performance stratified by patient demographics such as race, ethnicity, age, and pregnancy status. (iii) For devices with an intended use that includes detection of nucleic acid sequences from bacteria associated with bacterial vaginosis, a summary of device results in an asymptomatic population with demographic characteristics appropriate to the intended use population. (iv) For devices with an intended use that includes detection of either Candida species or bacteria associated with bacterial vaginosis, a limitation that *Candida* species and bacterial compositions associated with bacterial vaginosis can be present as part of normal vaginal flora and results should be considered in conjunction with available clinical information.

Recent Cleared Devices (12 of 12)

RecordDevice NameApplicantDecision DateDecision
K260021cobas® BV/CVRoche Molecular Systems, Inc.Jul 16, 2026SESE
K243725BD Vaginal PanelBecton, Dickinson and CompanyDec 19, 2024SESE
K243345Aptima BV Assay; Aptima CV/TV AssayHologic, Inc.Nov 25, 2024SESE
K231381Xpert Xpress MVP; GeneXpert Xpress SystemCepheidOct 19, 2023SESE
K223653BD Vaginal PanelBecton, Dickinson and CompanyMar 6, 2023SESE
K221160Xpert Xpress MVP, GeneXpert Dx System, GeneXpert Infinity SystemCepheidJun 7, 2022SESE
K212213Xpert Xpress MVP, GeneXpert Dx System, GeneXpert Infinity SystemCepheidFeb 9, 2022SESE
K201017BD MAX Vaginal Panel, BD MAX System, BD Molecular Swab Collection KitGeneohm Sciences Canada, Inc. (Bd Life Sciences)Oct 18, 2021SESE
K191957BD MAX Vaginal PanelGeneohm Sciences Canada, Inc. (Bd Diagnostics)Oct 21, 2019SESE
K190452Aptima BV AssayHologic, Inc.May 23, 2019SESE
K190472Aptima CV/TV AssayHologic, Inc.May 16, 2019SESE
DEN160001BD MAX Vaginal Panel, BD MAX InstrumentGeneohm Sciences Canada, Inc. (Bd Diagnostics)Oct 28, 2016DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...