K140455 · Trinity Biotech USA · PCL · May 22, 2014 · Microbiology
Device Facts
Record ID
K140455
Device Name
CAPTIA MEASLES IGM
Applicant
Trinity Biotech USA
Product Code
PCL · Microbiology
Decision Date
May 22, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 866.3520
Device Class
Class 1
Indications for Use
The Trinity Biotech Captia™ Measles IgM Enzyme-Linked Immunosorbent Assay (ELISA) is intended for the qualitative detection of Measles IgM antibodies in human serum of patients suspected of measles (rubeola) infection. This assay is intended for use as an aid in the diagnosis of a current or recent measles (rubeola) infection in conjunction with other clinical information and laboratory findings. Performance characteristics have not been evaluated in immunocompromised or immunosuppressed individuals. This test is not intended for use in neonatal screening or for use at a point of care. This test is not intended for use in screening blood and plasma donors.
Device Story
ELISA-based diagnostic test for qualitative detection of Measles IgM antibodies in human serum. Device uses microassay plates coated with Edmonston strain measles antigen. Patient serum added; antigen-specific IgM binds to solid-phase antigen. After washing, goat anti-human IgM conjugated with horseradish peroxidase (HRP) is added, binding to antigen-antibody complexes. TMB substrate added; enzymatic reaction produces blue color, turning yellow upon addition of 1N H2SO4 stop solution. Color intensity measured via spectrophotometer/ELISA plate reader. Used in clinical laboratories by trained personnel. Output is Immune Status Ratio (ISR) calculated from optical density relative to cut-off calibrator. Results aid clinicians in diagnosing current/recent measles infection alongside other clinical/laboratory data. Benefits include rapid identification of acute infection to support clinical management and public health response.
Clinical Evidence
Clinical performance evaluated via three studies (n=196 total). Studies 1 and 2 (n=188) compared Captia™ Measles IgM against a composite comparator algorithm (including other ELISA, IFA, CF, HI, and IgG tests). Study 3 (n=8) compared against PCR-based algorithms. Seroconversion study (n=15 samples over 55 days) demonstrated detection of IgM onset. Normal population study (n=200) established expected values. Analytical performance included precision/reproducibility (inter-assay, inter-lot, intra-run), cross-reactivity (CMV, HSV, etc.), and interference testing (hemoglobin, bilirubin).
Indicated for qualitative detection of Measles IgM antibodies in human serum of patients suspected of measles (rubeola) infection. Aid in diagnosis of current/recent infection. Not for immunocompromised/immunosuppressed individuals, neonatal screening, point-of-care, or blood/plasma donor screening.
Regulatory Classification
Identification
Rubeola (measles) virus serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to rubeola virus in serum. The identification aids in the diagnosis of measles and provides epidemiological information on the disease. Measles is an acute, highly infectious disease of the respiratory and reticuloendothelial tissues, particularly in children, characterized by a confluent and blotchy rash.
{0}
1
# 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY
A. 510(k) Number:
K140455
B. Purpose for Submission:
Clearance of New Device
C. Measurand:
Measles specific IgM antibodies
D. Type of Test:
Enzyme-Linked Immunosorbent Assay (ELISA)
E. Applicant:
Trinity Biotech
F. Proprietary and Established Names:
Captia™ Measles IgM
G. Regulatory Information:
1. Regulation section:
21 CFR 866.3520 Rubeola (measles) virus serological reagents
2. Classification:
Class I
3. Product code:
PCL
4. Panel:
83 (Micobiology)
H. Intended Use:
1. Intended use(s):
The Trinity Biotech Captia™ Measles IgM Enzyme-Linked Immunosorbent Assay (ELISA) is intended for the qualitative detection of Measles IgM antibodies in human serum of patients suspected of measles (rubeola) infection. This assay is intended for use as an aid in the diagnosis of a current or recent measles (rubeola) infection in conjunction with other clinical information and laboratory findings.
{1}
Performance characteristics have not been evaluated in immunocompromised or immunosuppressed individuals. This test is not intended for use in neonatal screening or for use at a point of care. This test is not intended for use in screening blood and plasma donors.
2. Indication(s) for use:
Same as Intended Use
3. Special conditions for use statement(s):
None
4. Special instrument requirements:
None
I. Device Description:
The Trinity Biotech Captia™ Measles IgM test is an Enzyme-Linked Immunosorbent Assays (ELISA). When measles antigen (Edmonston strain) is bound to the solid phase and brought into contact with a patient's serum, antigen specific antibody, if present, will bind to the antigen on the solid phase forming antigen-antibody complexes. Excess antibody is removed by washing. This is followed by the addition of goat anti-human IgM globulin conjugated with horseradish peroxidase which will bind to the antibody-antigen complexes. The excess conjugate is removed by washing, followed by the addition of Chromogen/Substrate tetramethylbenzidine (TMB). If specific antibody to the antigen is present in the patient's serum, a blue color develops. When the enzymatic reaction is stopped with 1N H₂SO₄, The contents of the wells turn yellow. The color, which is indicative of the concentration of antibody in the serum, can be read on a suitable spectrophotometer or ELISA microwell plate reader. Each kit contains the following components in sufficient quantities to perform the number of tests indicated on the package label.
1. Purified measles antigen coated microassay plate: 96 wells, configured in twelve 1x8 strips stored in a foil pouch with desiccant. (96T: one plate)
2. Calibrator: Human serum or defibrinated plasma. Sodium azide (< 0.1%) and pen/strep (0.01%) added as preservatives, with kit specific factor printed on vial label. The Calibrator is used to calibrate the assay to account for day-to-day fluctuations in temperature and other testing conditions. (96T: one vial, 0.4 mL)
3. Positive Control: Human serum or defibrinated plasma. Sodium azide (< 0.1%) and pen/strep (0.01%) added as preservatives, with established range printed on vial label. The Positive Control is utilized to control the positive range of the assay.(96T: one vial, 0.4 mL)
4. Negative Control: Human serum or defibrinated plasma. Sodium azide (< 0.1%) and pen/strep (0.01%) added as preservatives, with established range printed on vial label. The Negative Control is utilized to control the negative range of the assay (96T: one vial, 0.4 mL)
2
{2}
5. Horseradish-peroxidase (HRP) Conjugate: Ready to use. Goat anti-human IgM, containing ProClin® (0.1%) and gentamicin as preservatives. (96T: one bottle, 16 mL)
6. Serum Diluent Plus: Ready to use, Contains goat/sheep anti-human IgG for serum absorption to remove competing IgG, with protein stabilizers and ProClin® (0.1%) as a preservative. (96T: two bottles, 45 mL each)
7. Wash Buffer Type I (20X concentrate): dilute 1 part concentrate + 19 parts deionized or distilled water. Contains TBS, Tween-20 and ProClin® (0.1%) as a preservative. (96T: one bottle, 50 mL)
8. Chromogen/Substrate Solution Type I: Tetramethylbenzidine (TMB), ready to use. The reagent should remain closed when not in use. If allowed to evaporate, a precipitate may form in the reagent wells. (96T: one bottle, 15 mL)
9. Stop Solution: Ready to use, contains a 1N H₂SO₄ solution. (96T: one bottle, 15 mL)
10. Package Insert
J. Substantial Equivalence Information:
1. Predicate device name(s):
Gull Rubeola IgM ELISA kit
2. Predicate 510(k) number(s):
K904083
3. Comparison with predicate:
| Similarities | | |
| --- | --- | --- |
| Item | Device | Predicate |
| Indications for use | The Trinity Biotech
Captia™ Measles IgM
Enzyme-Linked
Immunosorbent Assay (ELISA) is intended for the qualitative detection of Measles IgM antibodies in human serum of patients suspected of measles (rubeola) infection. This assay is intended for use as an aid in the diagnosis of a current or recent measles (rubeola) infection in conjunction with other clinical information and laboratory findings. | The Gull Rubeola IgM ELISA test is intended for the qualitative detection of IgM antibody to rubeola (measles) virus in human serum. When performed according to the instructions, the Rubeola IgM ELISA test is of value in the determination of recent exposure to and infection with rubeola virus and in the diagnosis of rubeola virus-associated disease. |
{3}
| Similarities | | |
| --- | --- | --- |
| Item | Device | Predicate |
| | Performance characteristics have not been evaluated in immunocompromised or immunosuppressed individuals. This test is not intended for use in neonatal screening or for use at a point of care. This test is not intended for use in screening blood and plasma donors. | |
| Technology | Enzyme-Linked Immunosorbent Assay (ELISA) | Same |
| Specimen Types | Human Serum | Same |
| Differences | | |
| --- | --- | --- |
| Item | Device | Predicate |
| None | Not Applicable | Not Applicable |
K. Standard/Guidance Document Referenced (if applicable):
CLSI EP7-A2: Guidance for Interference Testing in Clinical Chemistry (Vol. 25, No.27 Second Ed) (Nov 2005)
CLSI H18-A4: Procedures for Handling & Processing Blood Specimens (2010)
CLSI EP5-A2: Guidance for Evaluation of Precision Performance of Quantitative Measurement Methods (Vol. 24, No. 25 Second Ed.) (Aug 2004).
CLSI EP12-A: Guidance for User Protocol for Evaluation of Qualitative Test Performance (Vol. 22, No. 14) (Sept 2002).
L. Test Principle:
The Trinity Biotech Captia™ Measles IgM test is an Enzyme-Linked Immunosorbent Assay (ELISA). When measles antigen (Edmonston strain) is bound to the solid phase and brought into contact with a patient's serum, antigen specific antibody, if present, will bind to the antigen on the solid phase forming antigen-antibody complexes. Excess antibody is removed by washing. This is followed by the addition of goat anti-human IgM globulin conjugated with horseradish peroxidase which will bind to the antibody-antigen complexes. The excess conjugate is removed by washing, followed by the addition of Chromogen/Substrate tetramethylbenzidine (TMB). If specific antibody to the antigen is present in the patient's
{4}
serum, a blue color develops. When the enzymatic reaction is stopped with $1\mathrm{N}$ $\mathrm{H}_2\mathrm{SO}_4$ , The contents of the wells turn yellow. The color, which is indicative of the concentration of antibody in the serum, can be read on a suitable spectrophotometer or ELISA microwell plate reader.
# M. Performance Characteristics (if/when applicable):
# 1. Analytical performance:
# a. Precision/Reproducibility:
The Trinity Biotech Captia™ Measles IgM ELISA Test Kit was evaluated for inter-assay precision. This study consisted of six (6) blinded proficiency panel members, varying in reactivity: Four (4) Low to Moderate Positive samples and two (2) Negative samples were run in triplicate at three (3) separate facilities. Testing at each site was done over 10 days by two (2) operators at each site resulting in a total number of 180 data points. The results are summarized below:
Precision between all sites
| Sample ID | ISR Site 1 N=60 | ISR Site 2 N=60 | ISR Site 3 N=60 | MEAN | STD DEV | % CV |
| --- | --- | --- | --- | --- | --- | --- |
| 1 | 1.30 | 1.34 | 1.23 | 1.29 | 0.055678 | 4.3% |
| 2 | 0.57 | 0.68 | 0.67 | 0.64 | 0.060828 | 9.5% |
| 3 | 1.16 | 1.26 | 1.07 | 1.16 | 0.095044 | 8.2% |
| 4 | 1.92 | 1.84 | 1.76 | 1.84 | 0.08000 | 4.3% |
| 5 | 0.67 | 0.82 | 0.84 | 0.78 | 0.092916 | 12.0% |
| 6 | 1.28 | 1.18 | 1.01 | 1.16 | 0.136504 | 11.8% |
The Trinity Biotech Captia™ Measles IgM ELISA Test Kit was evaluated for lot to lot precision. This study consisted of six (6) blinded proficiency panel members, varying in reactivity: four (4) Low to Moderate Positive samples and two (2) Negative samples run in triplicate on three (3) separately manufactured kit lots. The results are summarized below:
Inter-lot Reproducibility
| Sample ID | ISR Lot 1 | ISR Lot 2 | ISR Lot 3 | Mean | Std Dev | % CV |
| --- | --- | --- | --- | --- | --- | --- |
| 1 | 1.22 | 1.43 | 1.36 | 1.34 | 0.120773 | 9.02 |
| 2 | 0.57 | 0.42 | 0.46 | 0.48 | 0.108972 | 22.55 |
| 3 | 1.19 | 1.31 | 1.24 | 1.25 | 0.103253 | 8.27 |
| 4 | 2.13 | 1.96 | 1.56 | 1.88 | 0.27924 | 14.83 |
| 5 | 0.79 | 0.75 | 0.56 | 0.7 | 0.109545 | 15.72 |
| 6 | 1.27 | 1.32 | 1.3 | 1.29 | 0.041265 | 3.19 |
{5}
A separate precision/reproducibility study was performed internally (Trinity Biotech, Jamestown) using one (1) lot of the Captia™ Measles IgM ELISA Test Kit. The study compared the consistency between two (2) Operators. This study consisted of six (6) blinded proficiency panel members, varying in reactivity: Four (4) Low to Moderate Positive samples and two (2) Negative samples were run by each of the operators over 10 days. The results are summarized below:
Intra-run Precision/Reproducibility Between users:
Total Precision at Site 1 with Two Operators Over Ten Days
| Sample ID | ISR Operator 1
N=30 | ISR Operator 2
N=30 | MEAN ISR | STD DEV | % CV |
| --- | --- | --- | --- | --- | --- |
| 1 | 1.26 | 1.33 | 1.3 | 0.0495 | 3.80% |
| 2 | 0.58 | 0.55 | 0.57 | 0.02121 | 3.80% |
| 3 | 1.14 | 1.17 | 1.16 | 0.02121 | 1.80% |
| 4 | 1.92 | 1.91 | 1.92 | 0.00707 | 0.40% |
| 5 | 0.69 | 0.65 | 0.67 | 0.02828 | 4.20% |
| 6 | 1.32 | 1.23 | 1.28 | 0.06364 | 5.00% |
b. Linearity/assay reportable range:
Not Applicable
c. Traceability, Stability, Expected values (controls, calibrators, or methods):
Traceability – The Controls and Calibrators are traceable against frozen internal Quality Control standard panels. The panels consist of patient samples whose values span the assay range.
Stability – Real time stability studies support the shelf life of the Reagents, Controls and Calibrators at $2 - 8^{\circ}\mathrm{C}$ up to the stated expiration date on the labeling.
Expected Values – The ISR (Immune Status Ratio) Values for the Positive and Negative Controls should be in their respective ranges printed on the vial labels. If the Control values are not within their respective ranges, the test should be considered invalid and should be repeated.
d. Detection limit:
Not Applicable
{6}
# e. Analytical specificity:
# Cross Reactivity:
A total of 47 samples were used for establishing the potential cross reactivity of the Trinity Biotech Captia™ Measles IgM ELISA Test Kit. The samples were selected as confirmed positive by Trinity Biotech Captia™ CMV IgM, HSV1 IgM, HSV2 IgM, Rubella IgM, VZV IgM and Mumps IgM test kits, for each of the following potentially cross-reacting agents: CMV, HSV-1, HSV-2, Rubella, VZV, Mumps and Parvo-B19. Fourteen (14) of the suspected cross reactive samples tested as measles IgM antibody positive or equivocal (12 positive and 2 equivocal) with the Trinity Biotech Captia™ Measles IgM ELISA test kit. These 14 samples were then run on a comparator Measles IgM IFA test kit and a comparator Measles IgM ELISA test kit. A sample was determined as measles IgM antibody positive if the results on two (2) measles IgM tests were positive. A sample was determined as measles IgM antibody negative if the results on two (2) measles IgM tests were negative. The results are presented in the table below:
| Cross Reacting Agents | Number of Samples | Trinity Biotech Captia™ Measles IgM Result | | | | Consensus Comparator Result* | |
| --- | --- | --- | --- | --- | --- | --- | --- |
| | | Neg | Pos | Equiv | | Neg | Pos |
| Mumps IgM | 4 | 4 | 0 | 0 | | NT | NT |
| VZV IgM | 4 | 4 | 0 | 0 | | NT | NT |
| Rubella IgM | 4 | 4 | 0 | 0 | | NT | NT |
| CMV IgM | 7 | 3 | 3 | 1 | | 3 | 1 |
| HSV1 IgM | 16 | 9 | 7 | 0 | | 5 | 2 |
| HSV 2 IgM | 10 | 7 | 2 | 1 | | 2 | 1 |
NT = Not tested
* Tested only if Captia™ Measles IgM result was positive.
Potential cross reactivity was observed with CMV IgM, HSV1 IgM and HSV2 IgM. Potential cross-reactivity with Parvovirus, Respiratory Syncytial Virus (RSV) and parainfluenza has not been ruled out, as either specimens were not tested or a limited number were tested.
# Interfering Substances:
Interfering substance testing was conducted using three (3) characterized samples for measles IgM, spiked with recommended interfering substances according to the guidance in the CLSI document EP7-A2 (Interference Testing in Clinical Chemistry; Approved Guideline 2nd Ed). Results from the three (3) samples tested as spiked with the interfering substance and unspiked (as a control) were favourable. No adverse results or significant change in results occurred with these samples tested with the following:
{7}
| Potential Interferent | Concentration |
| --- | --- |
| Hemoglobin | ≥500 mg/dL |
| Bilirubin (unconjugated) | ≥20 mg/dL |
Interferents with substances such as red cells, cholesterol, gamma globulin, triglycerides, beta carotene, protein, ascorbic acid and anticoagulants have not been tested.
## High Dose Hook Effect:
When antigen is evaluated for purchase, it is titrated to ensure that there is no dose hook effect (prozone) of antigen on the plate. If prozoning is apparent then the antigen is titrated out further past the prozone point.
Due to the nature of obtaining IgM positive serum in general, positive serum purchased for the Captia Measles IgM generally contains less antibody than would be present to demonstrate dose hook effect (prozone), although the positive control in each kit lot is titrated to negative at each kit QC test stage to ensure the positive control is not prozoning.
## IgM/IgG Competition:
Specific IgG may compete with the IgM for sites and may result in a false negative. Conversely, rheumatoid factor in the presence of specific IgG may result in a false positive reaction. The Serum Diluent Plus Solution diminishes competing virus-specific IgG and minimizes rheumatoid factor interference in samples. Studies indicate that the maximum amount of IgG which can be removed by the kit Serum Diluent Plus is in excess of the expected high end of the normal range for IgG > 1380 mg/dL. The highest titer of RF+ tested (1: 1280; 500 IU/mL) did not adversely affect the performance of the assay
## f. Assay cut-off:
The objective of this study was to demonstrate the performance of the Trinity Biotech Captia™ Measles IgM ELISA Test Kit; specifically to generate data to demonstrate determination of the cut-off. The results are summarized below:
Measles IgM negative sera (228) were assayed on the Trinity Biotech Captia™ Measles IgM ELISA Test Kit. Four (4) samples were disqualified as they were in the equivocal range on Trinity IgM ELISA or indeterminate on a comparator Measles IFA test kit (due to non-specific staining most likely due to the presence of ANA antibodies). The mean and standard deviation of the optical density readings for the sera were 0.105 and 0.070 respectively. The positive threshold for the assay was determined by adding the mean and 4 standard deviations (0.105 + 4(0.070) = 0.385). Positive sera were titrated to give a constant ratio of the threshold value to obtain a Cut-off Calibrator serum. On all subsequent assays, this serum was run and the assay was calibrated by multiplying the O.D. value for the calibrator by the ratio to the cut-
{8}
off to obtain the cut-off calibrator value. This value was then divided into the O.D. for the patient sera to obtain an Immune Status Ratio (ISR). By definition, the Cut-off ISR is equal to 1.00. To account for inherent variation in the immunoassay, values of 0.91 to 1.09 were considered equivocal. Therefore values $\leq 0.90$ are considered negative and values $\geq 1.10$ are considered positive.
2. Comparison studies:
a. Method comparison with predicate device:
Not Applicable
b. Matrix comparison:
Not Applicable
3. Clinical studies:
a. Clinical Sensitivity:
Not Applicable
b. Clinical specificity:
Not Applicable
c. Other clinical supportive data (when a. and b. are not applicable):
The clinical performance was evaluated using the results of three (3) studies that were conducted to evaluate the performance of the Trinity Biotech Captia™ Measles IgM ELISA test kit.
Studies 1 and 2:
A total of 188 samples were collected from individuals for whom a measles IgM test was ordered (suspected of measles infection in outbreak settings by the Texas Department of Health, Austin, Texas (66 samples) and the State Laboratory of Public Health in Raleigh, North Carolina (122 samples)). All serum samples were tested on the Trinity Biotech Captia™ Measles IgM ELISA test kit. All but one (1) sample was tested by a comparator testing algorithm used at each institution to determine the presence of current or recent measles infection, referred to as "comparator algorithm" in the performance tables. The algorithms used consisted of the results of other laboratory confirmation methods including comparator Measles IgM ELISA test kit, a comparator Measles IgM IFA test kit, Complement Fixation (CF), Hemagglutination Inhibition (HI) and the Trinity Biotech Captia™ Measles ELISA IgG test kit. See the table below for results.
9
{9}
10
# Comparator Algorithm
| | + | Indeterminate | - |
| --- | --- | --- | --- |
| + | 88 | 1 | 6 |
| Equivocal | 3 | 3 | 10 |
| - | 5 | 1 | 70 |
# Percent of Captia™ Measles IgM Results that are
Equivocal = 8.6% (16 of 187)
Performance with the indeterminate results from the comparator algorithm calculated against the performance of the Captia™ Measles IgM:
# Comparator Algorithm
| | + | Indeterminate | - |
| --- | --- | --- | --- |
| + | 88 | 1 | 6 |
| Equivocal | 3 | 3 | 10 |
| - | 5 | 1 | 70 |
# Study 3:
Eight (8) samples were submitted for testing at the Kansas Department of Health and Environment Laboratory (KDHE), Topeka, Kansas. All samples were tested on the Captia™ Measles IgM and Captia™ Measles IgG ELISA test kits as well as compared with the method used by the testing institution to determine the presence of current or recent measles infection, referred to as “comparator algorithm” in the performance table. The comparator algorithm included RNA polymerase chain reaction (PCR) on urine, nasopharyngeal swab (NPS) and/or throat swab (TS) samples. The final % agreement is presented in the table below:
{10}
11
| Trinity Biotech Captia™
Measles IgM | Comparator Algorithm | | | |
| --- | --- | --- | --- | --- |
| | | + | Indeterminate | - |
| | + | 3 | 0 | 0 |
| | Equivocal | 0 | 0 | 0 |
| | - | 0 | 1* | 4 |
| | # Agree | Total | Result | 95% CI |
| % Positive Agreement | 3 | 3 | 100.00% | 29.2-100.0% |
| % Negative Agreement | 4 | 4 | 100.00% | 39.8-100.0% |
* This sample tested NPS negative at two sites, urine positive at one site and urine indeterminate at one site (all testing done by PCR).
Performance with the indeterminate results from the comparator algorithm calculated against the performance of the Captia™ Measles IgM:
| Trinity Biotech Captia™
Measles IgM | Comparator Algorithm | | | |
| --- | --- | --- | --- | --- |
| | | + | Indeterminate | - |
| | + | 3 | 0 | 0 |
| | Equivocal | 0 | 0 | 0 |
| | - | 0 | 1* | 4 |
| | # Agree | Total | Result | 95% CI |
| % Positive Agreement | 3 | 4 | 75.00% | 30.1-95.4% |
| % Negative Agreement | 4 | 4 | 100.00% | 39.8-100.0% |
# Seroconversion study:
The BIOMEX Rubeola IgG and IgM Antibody Seroconversion Panel (Cat No. SCP-MEA-001) contained 15 samples depicting the onset and decline of IgG and IgM antibodies to Rubeloa (Measles) from one individual over a period of 55 days. The IgM response was tested on four (4) different lots of the Trinity Biotech Captia™ Measles IgM ELISA Test Kit. The seroconversion panel consisted of one patient with 15 draws during an approximately two month period from May 31st to July 25th, 1994. Seroconversion was demonstrated at Day 20 with the Trinity Biotech Captia™ Measles IgM ELISA Test Kit, and remained positive until Day 22. The first comparator assay (comparator 1) demonstrated seroconversion at Day 22 and was positive only at that bleed date. The second comparator assay (comparator 2) seroconversion happened earlier than the Trinity kit by 2 days and remained positive for the remainder of the timeframe. The results are summarized below:
{11}
| | Trinity Biotech Captia™ Measles IgM ELISA | | | | | | | | Comparator 1 Rubeola IgM | Comparator 2 Rubeola IgM | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| | Lot 027 | | Lot 28 | | Lot 29 | | Lot 030 | | | | | |
| Bleed Day | ISR | Result | ISR | Result | ISR | Result | ISR | Result | S/CO | Result | S/CO | Result |
| Day1 | 0.22 | Neg | 0.29 | Neg | 0.2 | Neg | 0.12 | Neg | NT | NT | 0.429 | Neg |
| Day 6 | 0.29 | Neg | 0.33 | Neg | 0.24 | Neg | 0.15 | Neg | 0.02 | Neg | 0.449 | Neg |
| Day 8 | 0.25 | Neg | 0.31 | Neg | 0.21 | Neg | 0.14 | Neg | -0.04 | Neg | 0.389 | Neg |
| Day 13 | 0.26 | Neg | 0.34 | Neg | 0.27 | Neg | 0.21 | Neg | 0.28 | Neg | 1.101 | Pos |
| Day 15 | 0.44 | Neg | 0.51 | Neg | 0.54 | Neg | 0.43 | Neg | 0.46 | Neg | 3.045 | Pos |
| Day 20 | 1.53 | Pos | 1.71 | Pos | 1.77 | Pos | 1.28 | Pos | 0.92 | Neg | 7.332 | Pos |
| Day 22 | 1.36 | Pos | 1.4 | Pos | 1.49 | Pos | 1.24 | Pos | 1.09 | Pos | 5.919 | Pos |
| Day 27 | 0.84 | Neg | 0.92 | equiv | 0.96 | Equiv | 0.71 | Neg | 0.5 | Neg | 3.785 | Pos |
| Day 29 | 0.59 | Neg | 0.8 | Neg | 0.89 | Neg | 0.54 | Neg | 0.33 | Neg | 3.296 | Pos |
| Day 35 | 0.54 | Neg | 0.63 | Neg | 0.62 | Neg | 0.47 | Neg | 0.61 | Neg | 2.449 | Pos |
| Day 37 | 0.44 | Neg | 0.53 | Neg | 0.53 | Neg | 0.79 | Neg | 0.24 | Neg | 2.113 | Pos |
| Day 43 | 0.44 | Neg | 0.6 | Neg | 0.54 | Neg | 0.38 | Neg | 0.17 | Neg | 2.04 | Pos |
| Day 45 | 0.37 | Neg | 0.5 | Neg | 0.5 | Neg | 0.31 | Neg | 0.15 | Neg | 1.802 | Pos |
| Day 49 | 0.34 | Neg | 0.59 | Neg | 0.39 | Neg | 0.28 | Neg | 0.04 | Neg | 1.471 | Pos |
| Day 54 | 0.38 | Neg | 0.5 | Neg | 0.42 | Neg | 0.29 | Neg | 0.27 | Neg | 1.47 | Pos |
Specificity in a Normal Population:
A total of 200 random serum samples were tested to establish the expected values in a population of individuals between the ages 18-65 with no known clinically apparent Measles infection. The table below summarizes the distribution of Trinity Biotech Measles IgM assay ISR Values observed for the population.
Distribution of Trinity Biotech Captia™ Measles IgM Assay ISR Values from a Normal Population
| Measles IgM ISR Range | Number of Specimens | Percent of Total |
| --- | --- | --- |
| 0.00-0.20 | 65 | 32.5% |
| 0.21-0.40 | 91 | 45.5% |
| 0.41-0.60 | 29 | 14.5% |
| 0.61-0.80 | 8 | 4.0% |
| 0.81-0.90 | 4 | 2.0% |
| 0.91-1.10 | 1 | 0.5% |
| 1.11-1.20 | 0 | 0.0% |
| 1.21-1.40 | 1 | 0.5% |
| >2.00 | 1 | 0.5% |
{12}

4. Clinical cut-off:
Not Applicable
5. Expected values/Reference range:
IgM antibodies appear in the first week of infection and usually peak within a month. Although uncommon, low levels of IgM may persist for one (1) year or longer. The annual incidence rates are reported to vary in different geographical areas. Recent reports (2004-2011) from the Centers for Disease Control and Prevention (CDC) indicate that annual measles incidence is $< 1$ reported case per 1 million population. A large proportion of cases $(40\%)$ are international imported or associated with importation. Unknown source cases are not linked to any endemic chain $(12\%)$ . Most imported cases do not lead to spread in the United States. This is attributed to high levels of vaccination coverage (CDC Report: Documentation and Verification of Measles, Rubella and Congenital Rubella Syndrome Elimination in the Region of the Americas, United States National Report, CDC, March 28, 2012).
N. Proposed Labeling:
The labeling is sufficient and it satisfies the requirements of 21 CFR Part 809.10.
O. Conclusion:
The submitted information in this premarket notification is complete and supports a substantial equivalence decision.