Browse hierarchy: [Microbiology (MI)](/submissions/MI) → [Subpart D — Serological Reagents](/submissions/MI/subpart-d%E2%80%94serological-reagents) → [21 CFR 866.3170](/submissions/MI/subpart-d%E2%80%94serological-reagents/866.3170) → MZP — Assay, Hybridization And/Or Nucleic Acid Amplification For Detection Of Hepatitis C Rna,Hepatitis C Virus

# MZP · Assay, Hybridization And/Or Nucleic Acid Amplification For Detection Of Hepatitis C Rna,Hepatitis C Virus

_Microbiology · 21 CFR 866.3170 · Class 2_

**Canonical URL:** https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP

## Overview

- **Product Code:** MZP
- **Device Name:** Assay, Hybridization And/Or Nucleic Acid Amplification For Detection Of Hepatitis C Rna,Hepatitis C Virus
- **Regulation:** [21 CFR 866.3170](/submissions/MI/subpart-d%E2%80%94serological-reagents/866.3170)
- **Device Class:** 2
- **Review Panel:** [Microbiology](/submissions/MI)

## Identification

A nucleic acid-based hepatitis C virus (HCV) ribonucleic acid (RNA) test is identified as an in vitro diagnostic device intended for prescription use as an aid in the diagnosis of HCV infection in specified populations, and/or as an aid in the management of HCV-infected patients including guiding the selection of genotype-specific treatment in individuals with chronic HCV infection. The test is intended for use with human serum or plasma. The test is not intended for use as a donor screening test for the presence of HCV antibodies in blood, blood products, or tissue donors.

## Classification Rationale

Class II (special controls). The special controls for this device are:

## Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) For all nucleic acid-based HCV RNA tests, the labeling required under § 809.10(b) of this chapter must include:
(i) A prominent statement that the test is not intended for use as a donor screening test for the presence of HCV RNA from human cells, tissues, and cellular and tissue-based products.
(ii) A detailed explanation of the principles of operation and procedures for performing the assay.
(iii) A detailed explanation of the interpretation of results.
(iv) Limitations, which must be updated to reflect current clinical practice and disease presentation and management. These limitations must include, but are not limited to, statements that indicate:
(A) The specimen types for which the device has been cleared and that use of this test kit with specimen types other than those specifically cleared for this device may result in inaccurate test results.
(B) When applicable, that assay performance characteristics have not been established in populations of immunocompromised or immunosuppressed patients or, other populations where test performance may be affected.
(C) Test results are to be interpreted by qualified licensed healthcare professionals in conjunction with the individual's clinical presentation, history, and other laboratory results.
(2) For all nucleic acid-based HCV RNA tests, the design verification and validation must include:
(i) Detailed device description, including the device components, ancillary reagents required but not provided, and an explanation of the device methodology. Additional information appropriate to the technology must be included such as design of primers and probes, rationale for the selected gene targets, specifications for amplicon size, and degree of nucleic acid sequence conservation.
(ii) For devices with assay calibrators, the design and nature of all primary, secondary, and subsequent quantitation standards used for calibration as well as their traceability to a standardized reference material that FDA has determined is appropriate (
*e.g.,* a recognized consensus standard). In addition, analytical testing must be performed following the release of a new lot of the standard material that was used for device clearance or approval, or when there is a transition to a new calibration standard.(iii) Documentation and characterization (
*e.g.,* determination of the identity, supplier, purity, and stability) of all critical reagents (including nucleic acid sequences for primers and probes) and protocols for maintaining product integrity.(iv) Detailed documentation of analytical performance studies conducted as appropriate to the technology, specimen types tested, and intended use of the device, including, but not limited to, limit of detection (LoD), upper and lower limits of quantitation (ULoQ and LLoQ, respectively), linearity, precision, endogenous and exogenous interferences, cross reactivity, carryover, matrix equivalency, and sample and reagent stability. Samples selected for use in analytical studies or used to prepare samples for use in analytical studies must be from subjects with clinically relevant circulating genotypes in the United States. Cross-reactivity studies must include samples from HCV RNA negative subjects with other causes of liver disease, including autoimmune hepatitis, alcoholic liver disease, chronic hepatitis B virus, primary biliary cirrhosis, and nonalcoholic steatohepatitis, when applicable. The effect of each claimed nucleic-acid isolation and purification procedure on detection must be evaluated.
(v) Risk analysis and management strategies, such as Failure Modes Effects Analysis and/or Hazard Analysis and Critical Control Points summaries and their impact on test performance.
(vi) Final release criteria to be used for manufactured test lots with appropriate evidence that lots released at the extremes of the specifications will meet the claimed analytical and clinical performance characteristics as well as the stability claims.
(vii) Multisite reproducibility study that includes the testing of three independent production lots.
(viii) All stability protocols, including acceptance criteria.
(ix) Final release test results for each lot used in clinical studies.
(x) Analytical sensitivity and specificity of the test must be the same or better than that of other cleared or approved tests.
(xi) Lot-to-lot precision studies, as appropriate.
(3) For devices intended for the qualitative detection of HCV RNA, in addition to the special controls listed in paragraphs (b)(1) and (2) of this section, the design verification and validation must include detailed documentation of performance from a multisite clinical study. Performance must be analyzed relative to an FDA cleared or approved qualitative HCV RNA test, or a comparator that FDA has determined is appropriate. This study must be conducted using appropriate patient samples, with appropriate numbers of HCV positive and negative samples in applicable risk categories. Additional genotypes must be validated using appropriate numbers and types of samples. The samples may be a combination of fresh and repository samples, sourced from within and outside the United States, as appropriate. The study designs, including number of samples tested, must be sufficient to meet the following criteria:
(i) Clinical sensitivity of the test must have a lower bound of the 95 percent confidence interval of greater than or equal to 95 percent.
(ii) Clinical specificity of the test must have a lower bound of the 95 percent confidence interval of greater than or equal to 96 percent.
(4) For devices intended for the quantitative detection of HCV RNA, the following special controls, in addition to those listed in paragraphs (b)(1) and (2) of this section, apply:
(i) Labeling required under § 809.10(b) of this chapter must include a prominent statement that the test is not intended as a diagnostic test to confirm the presence of active HCV infection, when applicable.
(ii) Design verification and validation must include the following:
(A) Detailed documentation of the following analytical performance studies conducted as appropriate to the technology, specimen types tested, and intended use of the device, including but not limited to: LoD, ULoQ and LLoQ. LoD, LLoQ, and linearity studies must demonstrate acceptable device performance with all HCV genotypes detected by the device.
(B) Detailed documentation of clinical performance testing from either:
(
*1* ) A multisite clinical study with an appropriate number of clinical samples from chronically HCV infected patients in which the results are compared to an FDA-cleared or approved quantitative HCV RNA test, or a comparator that FDA has determined is appropriate. This study must include a sufficient number of HCV positive samples containing an analyte concentration near the LLoQ to describe performance at this level. Clinical samples must cover the full range of the device output and must be consistent with the distribution of these genotypes in the U.S. population. Clinical samples may be supplemented with diluted clinical samples for those viral load concentrations that are not sufficiently covered by natural clinical specimens, or(
*2* ) A clinical study with prospectively collected samples demonstrating clinical validity of the device.(C) Detailed documentation of a qualitative analysis near the lower end of the measuring range demonstrating acceptable performance when used as an aid in diagnosis.
(5) For devices intended for HCV RNA genotyping, in addition to the special controls listed in paragraphs (b)(1) and (2) of this section, design verification and validation must include the following:
(i) Detailed documentation of an analytical performance study demonstrating the LoD for all HCV genotypes detected by the device.
(ii) Detailed documentation, including results, of a multisite clinical study that assesses genotyping accuracy (
*i.e.,* the proportion of interpretable results that match with the reference method result) and the genotyping rate (*i.e.,* the proportion of results that were interpretable).(6) For any nucleic acid-based HCV RNA test intended for Point of Care (PoC) use, the following special controls, in addition to those listed in paragraphs (b)(1) and (2) of this section, apply:
(i) Clinical studies must be conducted at PoC sites.
(ii) Additional labeling must include a brief summary of the instructions for use that are appropriate for use in a PoC environment.

## Recent Cleared Devices (13 of 13)

| Record | Device Name | Applicant | Decision Date | Decision |
| --- | --- | --- | --- | --- |
| [K252484](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/K252484.md) | cobas HCV | Roche Molecular Systems, Inc. | Nov 3, 2025 | SESE |
| [K252102](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/K252102.md) | Alinity m HCV | Abbott Molecular, Inc. | Sep 25, 2025 | SESE |
| [K233352](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/K233352.md) | Aptima HCV Quant Dx Assay | Hologic, Inc. | Jul 24, 2024 | SESE |
| [K221007](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/K221007.md) | cobas HCV | Roche Molecular Systems, Inc. | Nov 4, 2022 | SESE |
| [P190025](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P190025.md) | Alinity m HCV | Abbott Molecular, Inc. | Mar 23, 2020 | APRL |
| [P160023](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P160023.md) | APTIMA HCV QUANT DX ASSAY | Hologic, Inc. | Feb 13, 2017 | APRL |
| [P150015](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P150015.md) | COBAS HCV TEST | Roche Molecular Systems, Inc. | Oct 14, 2015 | APRL |
| [P100017](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P100017.md) | ABBOTT REALTIME HCV, ABBOTT REALTIME HCV AMPLIFICATION REAGENT KIT, ABBOTT REALTIME HVC CONTROL KIT, ABBOTT REALTIME HCV | Abbott Molecular, Inc. | May 17, 2011 | APRL |
| [P060030](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P060030.md) | COBAS AMPLIPREP/COBAS TAQMAN HCV TEST | Roche Molecular Systems, Inc. | Oct 30, 2008 | APRL |
| [P020022](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P020022.md) | BAYER VERSANT (TM) HCV RNA 3.0 ASSAY (BDNA) | Siemens Healthcare Diagnostics, Inc. | Mar 28, 2003 | APWD |
| [P020011](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P020011.md) | VERSANT HCV RNA QUALITATIVE ASSAY | Gen-Probe | Nov 7, 2002 | APRL |
| [P000010](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P000010.md) | AMPLICOR HEPATITIS C VIRUS (HCV) TEST VERSION 2.0 | Roche Molecular Systems, Inc. | Jul 5, 2001 | APWD |
| [P000012](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP/P000012.md) | COBAS AMPLICOR (TM) HEPATITIS C VIRUS (HCV) TEST, V2.0 | Roche Molecular Systems, Inc. | Jul 3, 2001 | APWD |

## Top Applicants

- Roche Molecular Systems, Inc. — 6 clearances
- Abbott Molecular, Inc. — 3 clearances
- Hologic, Inc. — 2 clearances
- Siemens Healthcare Diagnostics, Inc. — 1 clearance
- Gen-Probe — 1 clearance

---

**Source:** [https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/MZP)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
