← Product Code [LOL](/submissions/MI/subpart-d%E2%80%94serological-reagents/LOL) · K103529

# LIAISON XL ANALYZER MODEL 10050 (K103529)

_DiaSorin, Inc. · LOL · Jan 21, 2011 · Microbiology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/LOL/K103529

## Device Facts

- **Applicant:** DiaSorin, Inc.
- **Product Code:** [LOL](/submissions/MI/subpart-d%E2%80%94serological-reagents/LOL.md)
- **Decision Date:** Jan 21, 2011
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 866.3310
- **Device Class:** Class 2
- **Review Panel:** Microbiology

## Indications for Use

The LIAISON® Anti-HAV assay is an in vitro chemiluminescent immunoassay intended for the qualitative detection of total antibodies to hepatitis A (anti-HAV) in human serum and sodium heparin plasma samples using the LIAISON® Analyzer family. The assay is indicated as an aid in the laboratory diagnosis of current or previous HAV infections in conjunction with other serological and clinical information and to determine the presence of an antibody response to HAV in vaccine recipients. This assay is not intended for screening blood or solid or soft tissue donors. Assay performance characteristics have not been established for immunocompromised or immunosuppressed patients. The user is responsible for establishing assay performance characteristics in these populations. Caution: U.S. Federal Law restricts this device to sale by or on the order of a physician. The LIAISON® XL Analyzer is an automated discrete continuous loading chemiluminescent immunoassay (CLIA) analyzer for in vitro diagnostic analysis of CLIAs on human serum or plasma. The system menu includes infectious disease, bone and mineral, and endocrinology CLIAs. It is to be used only with FDA cleared chemilyminescence immunoassays that are marketed by DiaSorin for the LIAISON XL Analyzer. The LIAISON® Control Anti-HAV (negative and positive) is intended for use as assayed quality control samples to monitor the performance of the LIAISON® Anti-HAV assay. The performance characteristics of LIAISON® controls have not been established for any other assays or instrument platforms different from LIAISON® and LIAISON® XL.

## Device Story

LIAISON® XL Analyzer is an automated, floor-standing, continuous-loading chemiluminescent immunoassay (CLIA) system for clinical laboratory use. It processes human serum or plasma samples to detect infectious disease, bone/mineral, and endocrinology markers. Input samples are processed via disposable tips; reagent levels are tracked via RF-ID technology. The system uses magnetic particle solid-phase technology and isoluminol-antibody conjugates. A competitive sandwich immunoassay principle is employed: anti-HAV in samples competes with conjugate for fixed HAV; light signal (RLU) measured by photomultiplier tube is inversely proportional to anti-HAV concentration. The system features automated pipetting, incubation, wash cycles, and data reduction. Results are displayed via touch-screen interface for physician review to aid clinical diagnosis. Benefits include increased throughput, automated maintenance, and improved resource management compared to the predicate LIAISON® Analyzer.

## Clinical Evidence

No clinical data provided; substantial equivalence is based on bench testing and performance comparisons between the LIAISON® XL and the predicate LIAISON® Analyzer.

## Technological Characteristics

Automated CLIA analyzer; magnetic particle solid-phase; photomultiplier tube (PMT) optical system (450 nm emission); 36°C reaction temperature; RF-ID reagent tracking; disposable sample tips; continuous loading; touch-screen interface; LIS connectivity.

## Regulatory Identification

HAV serological assays are devices that consist of antigens and antisera for the detection of hepatitis A virus-specific IgM, IgG, or total antibodies (IgM and IgG), in human serum or plasma. These devices are used for testing specimens from individuals who have signs and symptoms consistent with acute hepatitis to determine if an individual has been previously infected with HAV, or as an aid to identify HAV-susceptible individuals. The detection of these antibodies aids in the clinical laboratory diagnosis of an acute or past infection by HAV in conjunction with other clinical laboratory findings. These devices are not intended for screening blood or solid or soft tissue donors.

## Special Controls

*Classification.* Class II (special controls). The special control is “Guidance for Industry and FDA Staff: Class II Special Controls Guidance Document: Hepatitis A Virus Serological Assays.” See § 866.1(e) for the availability of this guidance document.

## Predicate Devices

- LIAISON® Analyzer ([K082050](/device/K082050.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K103529

DiaSorin LIAISON® XL Analyzer Premarket Notification

### 5.0 510(k) SUMMARY

### SUBMITTED BY:

JAN 2 1 2011

Mari Mever Senior Manager, Regulatory/Clinical Affairs DiaSorin Inc. 1951 Northwestern Avenue P.O. Box 285 Stillwater, MN 55082-0285 Phone (651) 351-5635 Fax (651) 351-5669 Email: mari.mever@diasorin.com

## NAME OF DEVICE:

| Trade Name:                | LIAISON® Anti-HAV, LIAISON® XL Analyzer                                                |
|----------------------------|----------------------------------------------------------------------------------------|
| Common Names/Descriptions: | Hepatitis Anti-HAV, serological assay, Automated Chemiluminescent Immunoassay Analyzer |
| Regulation Number:         | 21 CFR 866.3310                                                                        |
| Regulation Name:           | Hepatitis A virus (HAV) serological assays                                             |
| Regulatory Class:          | Class II                                                                               |
| Product Code:              | LOL, JJF                                                                               |
| PREDICATE DEVICES:         | LIAISON® Analyzer Reference K082050                                                    |

### DEVICE DESCRIPTION:

### INTENDED USE:

The LIAISON® Anti-HAV assay is an in vitro chemiluminescent immunoassay intended for the qualitative detection of total antibodies to hepatitis A (anti-HAV) in human serum and sodium heparin plasma samples using the LIAISON® Analyzer family. The assay is indicated as an aid in the laboratory diagnosis of current or previous HAV infections in conjunction with other serological and clinical information and to determine the presence of an antibody response to HAV in vaccine recipients.

This assay is not intended for screening blood or solid or soft tissue donors. Assay performance characteristics have not been established for immunocompromised or immunosuppressed patients. The user is responsible for establishing assay performance characteristics in these populations. Caution: U.S. Federal Law restricts this device to sale by or on the order of a physician.

{1}------------------------------------------------

The LIAISON® XL Analyzer is an automated discrete continuous loading chemiluminescent immunoassay (CLIA) analyzer for in vitro diagnostic analysis of CLIAs on human serum or plasma. The system menu includes infectious disease, bone and mineral, and endocrinology CLIAs. It is to be used only with FDA cleared chemiluminescence immunoassays that are marketed by DiaSorin for the LIAISON XL Analyzer.

The LIAISON® Control Anti-HAV (negative and positive) is intended for use as assayed quality control samples to monitor the performance of the LIAISON® Anti-HAV assay.

The performance characteristics of LIAISON® controls have not been established for any other assays or instrument platforms different from LIAISON® and LIAISON® XL.

## DESCRIPTION:

The method for qualitative determination of anti-HAV is a competitive sandwich chemiluminescence immunoassay (CLIA) based on neutralization. Antibodies to HAV (mouse monoclonal) are used for coating magnetic particles (solid phase) and are linked to an isoluminol derivative (isoluminol-antibody conjugate). During the first incubation, anti-HAV present in calibrators, samples or controls binds to a fixed and limited amount of HAV, thus forming an HAV-anti-HAV immune complex. During the second incubation, the antibody conjugate and the solid-phase antibody compete with anti-HAV present in the specimen for HAV, that allows the conjugate to bind to the solid phase and thus form a "sandwich" of conjugate antibody-antigen-solid phase antibody. If all HAV added is sequestered in an HAVanti-HAV immune complex during the first incubation, no sandwich is formed during the second incubation. After the second incubation, the unbound material is removed with a wash cycle.

Subsequently, the starter reagents are added and a flash chemiluminescence reaction is thus induced. The light signal, and hence the amount of isoluminolantibody conjugate, is measured by a photomultiplier as relative light units (RLU) and is inversely indicative of anti-HAV present in calibrators, samples or controls

The LIAISON® XL Analyzer is an automated discrete continuous loading chemiluminescent immunoassay analyzer for in vitro diagnostic use.

{2}------------------------------------------------

.

COMPARISON TO PREDICATE DEVICE:
The following table compares the LIAISON® XL Analyzer to the LIAISON® Analyzer.

| Feature                                           | Summary of Device Similarities and Differences:<br>LIAISON® Analyzer                                                                                                                                                                                                                                                                                                                        | LIAISON® XL Analyzer                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|---------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| FDA K#                                            | K032844/K082050                                                                                                                                                                                                                                                                                                                                                                             | N/A                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |
| Intended Use                                      | Automated chemiluminescent analyzer for clinical use                                                                                                                                                                                                                                                                                                                                        | Same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Principles of operation                           | Chemiluminescence using magnetic particle solid phase and<br>chemiluminescent tracer                                                                                                                                                                                                                                                                                                        | Same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Optical System                                    | High-sensitive, low-noise<br>photomultiplier tube (PMT) operating<br>as an ultra-fast photon counter.<br>Pulses are amplified by a rapid<br>electronic amplifier.                                                                                                                                                                                                                           | Same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Circuit that suppresses PMT signal noise.                                                                                                                                                                                                                                                                                                                                                   | Same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Linear measuring range = 300 – 650 nm                                                                                                                                                                                                                                                                                                                                                       | Same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Light peak of chemiluminescence emitted at 450 nm                                                                                                                                                                                                                                                                                                                                           | Same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Temperature Control:<br>• Reaction<br>Temperature | $36°C±1°C$                                                                                                                                                                                                                                                                                                                                                                                  | $36°C±1°C$                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| • Reagent Storage<br>Temperature                  | 12-19°C                                                                                                                                                                                                                                                                                                                                                                                     | 11-15°C                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               |
| Dispense System                                   | Automated pipetting of samples and<br>reagents. Left pipetting unit used for<br>samples; right pipetting unit used for<br>reagents                                                                                                                                                                                                                                                          | same<br>(sample pipetting: disposable tip)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
|                                                   | Precision syringes (sample and reagent)                                                                                                                                                                                                                                                                                                                                                     | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Sample Probe:<br>• Liquid Level Detection<br>(capacitive)<br>• Clot Detection feature<br>(software algorithm based on<br>capacitive signal)                                                                                                                                                                                                                                                 | Sample Probe (disposable tip):<br>• Liquid Level Detection and<br>• Clot Detection feature<br>(pressure)                                                                                                                                                                                                                                                                                                                                                                                                                                              |
|                                                   | N/A                                                                                                                                                                                                                                                                                                                                                                                         | Disposable tips: 6 trays of 96 tips<br>each can be loaded on board.<br>Monitored through software<br>counter and presence sensor<br>upon tip pick-up.<br>Reloading allowed during run                                                                                                                                                                                                                                                                                                                                                                 |
|                                                   | Reagent Probes:<br>• Liquid Level Detection<br>(capacitive), with software<br>tracking of reagent level                                                                                                                                                                                                                                                                                     | Reagent Probes:<br>• Liquid Level Detection<br>(capacitive), with software<br>tracking of reagent level<br>• Optical Liquid Verification<br>(real-time monitoring of<br>liquid flow inside the<br>probe)                                                                                                                                                                                                                                                                                                                                              |
| Feature                                           | LIAISON® Analyzer                                                                                                                                                                                                                                                                                                                                                                           | LIAISON® XL Analyzer                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Sample Handling                                   | Capacity: Holds 12 sample racks, 12<br>places per rack<br>Tube types:<br>- primary tube<br>- aliquot tube<br>- pediatric<br>Sample presence, sample type<br>(calibrator, control, patient), tube size,<br>and processing completion tracked by<br>operating software and sample<br>barcode                                                                                                  | Capacity: Holds 10 sample racks,<br>12 places per rack<br>same<br>same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
| Reagent Handling                                  | Capacity: 15 Reagent Integrals (RI)<br><br>RI contains all reagents required for<br>any given assay (up to 7 vials per RI,<br>first always contains magnetic<br>particles).<br>Assay-specific processing and<br>analysis parameters, calibration, lot<br>number, expiration date, and usage<br>(number of tests run) are controlled<br>by operating software as<br>communicated by barcode. | Capacity: 25 Reagent Integrals<br>(RI), plus 4 positions for Ancillary<br>Reagents<br>same<br>Assay-specific processing and<br>analysis parameters, calibration,<br>lot number, expiration date, and<br>usage (number of tests run) are<br>controlled by operating software<br>as communicated by RF-Tag (RF-ID).                                                                                                                                                                                                                                     |
| Additional Reagents                               | • Control Set (2-3 levels)<br>• LIAISON Light Check (diagnostic<br>tool only)<br>• LIAISON Starter Kit (Starter<br>Reagents 1 and 2)<br>• LIAISON Wash/System Liquid<br>• LIAISON Cleaning Kit                                                                                                                                                                                              | • Control Set (2-3 levels)<br>• LIAISON Light Check<br>(diagnostic tool only)<br>• LIAISON Starter Kit (Starter<br>Reagents 1 and 2)<br>• LIAISON Wash/System<br>Liquid (used as a wash liquid<br>only - immunometric wash<br>step)<br>• LIAISON Cleaning Kit<br>In addition:<br>• Purified water is also required<br>as System Liquid, as fluidic<br>filler and to perform:<br>- reagent needle cleaning<br>- washer needle cleaning<br>• A cleaning tank is available to<br>host a cleaning liquid suitable<br>for automated maintenance<br>purpose |
|                                                   | Level sensing by capacitive rod                                                                                                                                                                                                                                                                                                                                                             | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Reaction Modules                                  | Capacity: 6 individual reaction<br>compartments per Reaction Module<br>Storage capacity: maximum 120<br>strips stored in LIAISON stacker                                                                                                                                                                                                                                                    | Single-cavity Cuvettes<br>Storage capacity: >600 Cuvettes                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
| Feature                                           | LIAISON® Analyzer                                                                                                                                                                                                                                                                                                                                                                           | LIAISON® XL Analyzer                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Reaction Modules (cont.)                          | Sensors detect presence of Reaction<br>Modules, and loading and occupancy<br>of stacker.                                                                                                                                                                                                                                                                                                    | Inventory monitoring through<br>software counter.<br>Sensors detect actual presence<br>of Cuvettes                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
|                                                   | Reloading allowed during run                                                                                                                                                                                                                                                                                                                                                                | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Test Processing                                   | Unloading automatic into waste bag<br>Random Access and Batch                                                                                                                                                                                                                                                                                                                               | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Continuous operation                                                                                                                                                                                                                                                                                                                                                                        | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Sample scheduling optimized for<br>throughput                                                                                                                                                                                                                                                                                                                                               | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Assay Protocols                                   | 1-Step assays: 1 incubation sequence<br>/ 1 wash sequence; average<br>incubation time = 10 minutes                                                                                                                                                                                                                                                                                          | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | 2-Step assays: 2 incubation sequence<br>/ 1 or 2 wash sequence(s); average<br>incubation time = 10 minutes                                                                                                                                                                                                                                                                                  | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Two-point calibration of assays                                                                                                                                                                                                                                                                                                                                                             | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Human Interface                                   | Computer Mouse and keyboard                                                                                                                                                                                                                                                                                                                                                                 | Touch-screen On Screen<br>Keyboard                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
|                                                   | Monitor - touch screen, color Printer Stationary barcode scanners for<br>identification of samples and<br>reagents                                                                                                                                                                                                                                                                          | same Printer (optional) Stationary barcode scanner<br>for identification of samples Stationary RF-Tag reader for<br>identification of reagents<br>(Reagent Integrals and<br>Starter Reagents) Handheld barcode scanner<br>for identification of controls                                                                                                                                                                                                                                                                                              |
|                                                   | Computer LIS Interface                                                                                                                                                                                                                                                                                                                                                                      | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Data Analysis                                     | Automated data reduction                                                                                                                                                                                                                                                                                                                                                                    | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Assay-specific Master Curve with 2-<br>point recalibration                                                                                                                                                                                                                                                                                                                                  | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Assay-specific data reduction                                                                                                                                                                                                                                                                                                                                                               | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| QC Software                                       | Stored lot-specific control results                                                                                                                                                                                                                                                                                                                                                         | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Lot-specific Levey-Jennings plotting                                                                                                                                                                                                                                                                                                                                                        | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Trend identification                                                                                                                                                                                                                                                                                                                                                                        | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Statistical analyses                                                                                                                                                                                                                                                                                                                                                                        | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Specimens                                         | Serum or plasma                                                                                                                                                                                                                                                                                                                                                                             | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | Sampling from primary, aliquot, or<br>pediatric tubes                                                                                                                                                                                                                                                                                                                                       | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Disposables                                       | Reagent Integrals Light Check (diagnostic tool) Starter Kit Wash/System Liquid Reaction Modules                                                                                                                                                                                                                                                                                             | same                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
|                                                   | N/A                                                                                                                                                                                                                                                                                                                                                                                         | Cuvettes Disposable Tips                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
|                                                   | Waste Bag Cleaning Kit                                                                                                                                                                                                                                                                                                                                                                      | same (dedicated)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |
| Feature                                           | LIAISON® Analyzer                                                                                                                                                                                                                                                                                                                                                                           | LIAISON® XL Analyzer                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |
| Hardware Improvements                             | LIAISON® Analyzer                                                                                                                                                                                                                                                                                                                                                                           | LIAISON® Analyzer, with enhancements as follows:<br>floor-standing, integrated design improved average throughput, Improved data exchange for Reagent Integrals, Ancillary Reagents, Starter Reagents via RF-ID technology Disposable tip for sample pipetting Continuous loading of all liquid and solid resources or waste Increased liquid/reagent capacity Increased efficiency of washer needle cleaning Automated Maintenance tasks On-line help: User Manual and Quick Guide directly accessible on screen                                     |

## Summary of Device Similarities and Differences:

{3}------------------------------------------------

{4}------------------------------------------------

{5}------------------------------------------------

## CONCLUSION:

The material submitted in this premarket notification is complete and supports the substantial equivalence of the LIAISON® XL Analyzer to the predicate device.

{6}------------------------------------------------

Image /page/6/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of an eagle or bird with its wings spread, symbolizing the department's mission to protect and promote the health and well-being of the nation.

Food and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993

DiaSorin, Inc. Attn: Mari Meyer 1951 Northwestern Ave. P.O. Box 285 Stillwater, MN 55082

JAN 2 1 201

Re: K103529

Trade/Device Name: LIAISON Anti-HAV, LIAISON XL Analyzer Regulation Number: 21 CFR 866.3310 Regulation Name: Hepatitis A virus (HAV) serological assays Regulatory Class: Class II Product Code: LOL, JJF Dated: November 30, 2010 Received: December 1, 2010

Dear Ms. Meyer:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition. FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21

Commission of the

Section of the country of the county

.

{7}------------------------------------------------

### Page 2 - Mari Meyer

CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Vacayartyr

Sally A. Hojvat, M.Sc., Ph.D. Director Division of Microbiology Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health

Enclosure

{8}------------------------------------------------

# Indications for Use

510(k) Number (if known): K103529

LIAISON® Anti-HAV, LIAISON® XL Analyzer Device Name:

Indications For Use:

The LIAISON® Anti-HAV assay is an in vitro chemiluminescent immunoassay intended for the qualitative detection of total antibodies to hepatitis A (anti-HAV) in human serum and sodium heparin plasma samples using the LIAISON® Analyzer family. The assay is indicated as an aid in the laboratory diagnosis of current or previous HAV infections in conjunction with other serological and clinical information and to determine the presence of an antibody response to HAV in vaccine recipients.

This assay is not intended for screening blood or solid or soft tissue donors. Assay performance characteristics have not been established for immunocompromised or immunosuppressed patients. The user is responsible for establishing assay performance characteristics in these populations. Caution: U.S. Federal Law restricts this device to sale by or on the order of a physician.

The LIAISON® XL Analyzer is an automated discrete continuous loading chemiluminescent immunoassay (CLIA) analyzer for in vitro diagnostic analysis of CLIAs on human serum or plasma. The system menu includes infectious disease, bone and mineral, and endocrinology CLIAs. It is to be used only with FDA cleared chemilyminescence immunoassays that are marketed by DiaSorin for the LIAISON XL Analyzer.

The LIAISON® Control Anti-HAV (negative and positive) is intended for use as assayed quality control samples to monitor the performance of the LIAISON® Anti-HAV assay.

The performance characteristics of LIAISON® controls have not been established for any other assays or instrument platforms different from LIAISON® and LIAISON® XL.

Prescription Use _ X (21 CFR Part 801 Subpart D) And/Or Over the Counter Use (21 CFR Part 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE; CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD)

Uhe Gey

Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety

510(k) k 103529

Page 1 of 1

---

**Source:** [https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/LOL/K103529](https://fda.innolitics.com/submissions/MI/subpart-d%E2%80%94serological-reagents/LOL/K103529)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
