GQL · Antisera, Fluorescent, Herpesvirus Hominis 1,2

Microbiology · 21 CFR 866.3305 · Class 2

Overview

Product CodeGQL
Device NameAntisera, Fluorescent, Herpesvirus Hominis 1,2
Regulation21 CFR 866.3305
Device ClassClass 2
Review PanelMicrobiology

Identification

Herpes simplex virus serological assays are devices that consist of antigens and antisera used in various serological tests to identify antibodies to herpes simplex virus in serum. Additionally, some of the assays consist of herpes simplex virus antisera conjugated with a fluorescent dye (immunofluorescent assays) used to identify herpes simplex virus directly from clinical specimens or tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of diseases caused by herpes simplex viruses and provides epidemiological information on these diseases. Herpes simplex viral infections range from common and mild lesions of the skin and mucous membranes to a severe form of encephalitis (inflammation of the brain). Neonatal herpes virus infections range from a mild infection to a severe generalized disease with a fatal outcome.

Classification Rationale

Class II (special controls). The device is classified as class II (special controls). The special control for the device is FDA's revised guidance document entitled “Class II Special Controls Guidance Document: Herpes Simplex Virus Types 1 and 2 Serological Assays.” For availability of the guidance revised document, see § 866.1(e).

Special Controls

*Classification.* Class II (special controls). The device is classified as class II (special controls). The special control for the device is FDA's revised guidance document entitled “Class II Special Controls Guidance Document: Herpes Simplex Virus Types 1 and 2 Serological Assays.” For availability of the guidance revised document, see § 866.1(e).

Recent Cleared Devices (20 of 37)

Showing 20 most recent of 37 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K091753ELVIS HSV ID AND D3 TYPING TEST SYSTEMDiagnostic Hybrids, Inc.Aug 28, 2009SESE
K081527LIGHT DIAGNOSTICS HSV 1/2 TYPING DFA KITMillipore CorporationApr 1, 2009SESE
K984135THE APTUS (AUTOMATED) APPLICATION OF THE HSV-1 IGG ELISA TEST SYSTEM. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) FORZeus Scientific, Inc.May 26, 1999SESE
K984120THE APTUS(AUTOMATED) APPLICATION OF THE HSV-2 IGG ELISA TEST SYSTEM. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) FOR THZeus Scientific, Inc.May 26, 1999SESE
K905608INDIRECT FLUORESCENT ASSAY FOR HERPES SIMPLEX 1Stellar Bio Systems, Inc.Nov 7, 1991SESE
K904095HERPES SIMPLEX VIRUS TISSUE CULTURE CONF. TYPINGCalifornia Integrated Diagnostics, Inc.Feb 1, 1991SESE
K904167PATHODX HERPES TYPINGDiagnostic Products Corp.Dec 13, 1990SESE
K902662BARTELS HERPES SIMPLEX VIR FLU MONO ANTIBODY TESTBaxter Healthcare CorpJul 31, 1990SESE
K902661BARTELS HERPES SIMPLEX VIR FLU MONO ANTIB HSV-1&2Baxter Healthcare CorpJul 31, 1990SESE
K891782HSV-2 ELISA TEST SYSTEMZeus Scientific, Inc.Jun 20, 1989SESE
K891162HSV-1 ELISA TEST SYSTEMZeus Scientific, Inc.Jun 20, 1989SESE
K891382ORTHO HSV 1&2 DICHROMATIC TYPING REAGENT & SLIDESOrtho Diagnostic Systems, Inc.Jun 6, 1989SESE
K870814HERPES SIMPLEX ANTIBODY TEST FOR DECT. OF HSV 1&2Microscan Div. Baxter Healthcare Corp.Jun 4, 1987SESE
K851635DIAGNON HERPES IMMUNOPEROXIDASE TYPING TESTDiagnon Corp.Oct 10, 1985SESE
K852360ORTHO DNA PROBE HSV CONFIRMATION TESTOrtho Diagnostic Systems, Inc.Sep 12, 1985SESE
K852125PATHFINDER DETECTION & COLLECTION KITS-HERPES SIMPKallestad Laboratories, Inc.Jul 30, 1985SESE
K851372CELLMATICS HERPES SIMPLEX VIRUS DETECT-SYSDifco Laboratories, Inc.Jul 12, 1985SESE
K841943GIBCO HERPES ID KITGibco Laboratories Life Technologies, Inc.Mar 13, 1985SESE
K850739AMENDMENT TO LABELING MICROTRAK HSV 1/HSV 2 DIRECTSyva Co.Mar 11, 1985SESE
K842216CULTURESET HSV ISOLATION & ID SYSOrtho Diagnostic Systems, Inc.Jan 29, 1985SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...