QBD · Microbial Nucleic Acid Storage And Stabilization Device

Microbiology · 21 CFR 866.2950 · Class 2

Overview

Product CodeQBD
Device NameMicrobial Nucleic Acid Storage And Stabilization Device
Regulation21 CFR 866.2950
Device ClassClass 2
Review PanelMicrobiology

Identification

A microbial nucleic acid storage and stabilization device is a device that consists of a container and reagents intended to stabilize microbial nucleic acids in human specimens for subsequent isolation and purification of nucleic acids for further molecular testing. The device is not intended for preserving morphology or viability of microorganisms.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

The special controls for this device are: (1) The intended use for the 21 CFR 809.10 labeling must include a detailed description of microorganisms and types of human specimens intended to be preserved. (2) The 21 CFR 809.10(b) labeling must include: (i) A detailed device description, including all device components. (ii) Performance characteristics from applicable analytical studies, including but not limited to, nucleic acid stability and microorganism inactivation. (iii) A limiting statement that erroneous results may occur when the transport device is not compatible with molecular testing. (iv) A limiting statement that the device has only been validated to preserve the representative microorganisms used in the analytical studies. (3) Design verification and validation must include the following: (i) Overall device design including all device components and all control elements incorporated into the analytical validation procedures. (ii) Thorough description of the microorganisms and methodology used in the validation of the device including, but not limited to, extraction platforms and assays used for the detection of preserved nucleic acids. (iii) The limit of detection (LoD) of the molecular test used to establish microorganism nucleic acid stability.

*Classification.* Class II (special controls). The special controls for this device are:(1) The intended use for the labeling required under § 809.10 of this chapter must include a detailed description of microorganisms and types of human specimens intended to be preserved. (2) The labeling required under § 809.10(b) of this chapter must include the following: (i) A detailed device description, including all device components; (ii) Performance characteristics from applicable analytical studies, including nucleic acid stability and microorganism inactivation; (iii) A limiting statement that erroneous results may occur when the transport device is not compatible with molecular testing; and (iv) A limiting statement that the device has only been validated to preserve the representative microorganisms used in the analytical studies. (3) Design verification and validation must include the following: (i) Overall device design, including all device components and all control elements incorporated into the analytical validation procedures; (ii) Thorough description of the microorganisms and methodology used in the validation of the device including, extraction platforms and assays used for the detection of preserved nucleic acids; and (iii) The limit of detection (LoD) of the molecular test used to establish microorganism nucleic acid stability.

Recent Cleared Devices (17 of 17)

RecordDevice NameApplicantDecision DateDecision
K242820Puritan PurSafe Plus Collection and Transport SystemPuritan Medical Products, LLCMay 27, 2025SESE
K240797PPH Saliva Collection KitPermantis Public HealthOct 11, 2024SESE
K222771Sample Preservative FluidHangzhou Bioer Technology Co., Ltd.Jun 26, 2024SESE
K233324Molecular Transport Media - MTMAlb LuzJun 17, 2024SESE
K221547InActiv BlueFertipro NVJun 11, 2024SESE
K212878Sample preservation solutionZhejiang Gene Science Co., Ltd.Apr 8, 2024SESE
K231013DNA/RNA Shield SafeCollect Saliva Collection kitZymo ResearchSep 28, 2023SESE
K221664CLEARinse CTS Specimen Collection and Transport SystemAardvark Medical, Inc.Jul 3, 2023SESE
K221802iSWAB-Respiratory Tract Sample Collection Media-Extraction Less (iSWAB-RC-EL)Mawi Dna TechnologiesApr 3, 2023SESE
K223497Spectrum Saliva Collection DeviceSpectrum Solutions, LLCFeb 17, 2023SESE
K220059Biosci™ Inactivated Transport Medium, Biosci™ ITMShenzhen Dakewe Bio-Engineering Co., Ltd.Jan 19, 2023SESE
K211675Dasky Disposable Sampling Tube (Model name: VSM02)Ningbo Dasky Life Science Co., Ltd.Aug 8, 2022SESE
K212113MagXtract Collection TubeMagbio Genomics, Inc.Jul 28, 2022SESE
K210440Disposable Sampler Inactivated Transport Media, Nest ITMWuxi Nest Biotechnology Co., Ltd.Sep 20, 2021SESE
K202641DNA/RNA Shield Collection TubeZymo ResearchDec 14, 2020SESE
K201849eNAT molecular collection and preservation mediumCopan Italia SpaSep 17, 2020SESE
DEN170029PrimeStore MTMLonghorn Vaccines and Diagnostics, LLCMar 19, 2018DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...