← Product Code [GMJ](/submissions/MI/subpart-d%E2%80%94serological-reagents/GMJ) · K760826

# HISTOPLASMA MYCELIAL ANTIGEN (K760826)

_I M, Inc. · GMJ · Nov 1, 1976 · Microbiology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/IM/subpart-d%E2%80%94serological-reagents/GMJ/K760826

## Device Facts

- **Applicant:** I M, Inc.
- **Product Code:** [GMJ](/submissions/MI/subpart-d%E2%80%94serological-reagents/GMJ.md)
- **Decision Date:** Nov 1, 1976
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 866.3320
- **Device Class:** Class 2
- **Review Panel:** Microbiology

## Regulatory Identification

Histoplasma capsulatum serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to Histoplasma capsulatum in serum. Additionally, some of these reagents consist of Histoplasma capsulatum antisera conjugated with a fluorescent dye (immunofluorescent reagents) used to identify Histoplasma capsulatum from clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the diagnosis of histoplasmosis caused by this fungus belonging to the genus Histoplasma and provides epidemiological information on the diseases caused by this fungus. Histoplasmosis usually is a mild and often asymptomatic respiratory infection, but in a small number of infected individuals the lesions may spread to practically all tissues and organs.

## Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

---

**Source:** [https://fda.innolitics.com/submissions/IM/subpart-d%E2%80%94serological-reagents/GMJ/K760826](https://fda.innolitics.com/submissions/IM/subpart-d%E2%80%94serological-reagents/GMJ/K760826)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).