Aesculap Aicon® Series Container System

K242762 · Aesculap, Inc. · KCT · May 13, 2025 · General Hospital

Device Facts

Record IDK242762
Device NameAesculap Aicon® Series Container System
ApplicantAesculap, Inc.
Product CodeKCT · General Hospital
Decision DateMay 13, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.6850
Device ClassClass 2

Indications for Use

The AESCULAP Aicon® Container is a reusable rigid sterilization container intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device during transport and until used. This container is compatible for use in the following sterilization modalities in the configurations listed below: - Ethylene Oxide (EtO) - STERIS V-PRO maX/maX 2: Lumen, Non-Lumen, Flex - STERIS V-PRO 60: Lumen, Non-Lumen, Flex - STERIS V-PRO S2 Non-Lumen - STERRAD 100NX: Standard, Express, Flex, Duo - STERRAD NX: Standard, Advanced - STERRAD 100S - STERIZONE VP4 - PreVac Steam The AESCULAP Aicon® consists of two different container styles: a solid bottom container and enhance drying system (EDS) container. The AESCULAP Aicon® Container is compatible with accessories such as baskets, trays, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders, and tags. Prevac cycles without dry times are Immediate Use Sterilization Cycles (IUSS).

Device Story

Reusable rigid sterilization container system; encloses medical devices for sterilization; maintains sterility during transport/storage. Composed of anodized aluminum container bottoms (standard or Enhanced Drying System) and lids; uses single-use polypropylene filters. Used in hospital sterile processing departments; operated by trained personnel. Input: medical instruments placed in baskets/trays within container. Operation: container allows sterilant penetration (EtO, VHP, Steam) while maintaining microbial barrier. Output: sterilized, packaged instruments ready for clinical use. Benefits: protects instruments from contamination; facilitates safe transport; ensures sterility maintenance until point of use.

Clinical Evidence

Bench testing only. No clinical data required. Testing included sterilization efficacy (SAL 10^-6), dry time validation, microbial aerosol challenge, cytotoxicity (ISO 10993-5), simulated use for flexible scopes, cleaning validation (TIR30), material compatibility (TIR17), and sterility maintenance (ISO 11167-1). All tests passed.

Technological Characteristics

Materials: Anodized aluminum (container/lid), silicone (gasket). Filter: Single-use polypropylene. Design: Solid bottom or EDS bottom with perforated lid. Sizes: Full, Three-Quarter, Half. Sterilization: EtO, VHP (STERIS/STERRAD/STERIZONE), PreVac Steam. Connectivity: None. Software: None.

Indications for Use

Indicated for use by healthcare providers to enclose medical devices for sterilization and to maintain sterility during transport and storage. Compatible with Ethylene Oxide, various STERIS V-PRO, STERRAD, STERIZONE VP4, and PreVac Steam sterilization cycles. Supports various load configurations including stainless steel lumens, flexible endoscopes, and non-lumened instruments.

Regulatory Classification

Identification

A sterilization wrap (pack, sterilization wrapper, bag, or accessories, is a device intended to be used to enclose another medical device that is to be sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device and also to maintain sterility of the enclosed device until used.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION May 13, 2025 Aesculap Inc. Hamza Ahmed Regulatory Affairs Specialist 3773 Corporate Pkwy Center Valley, Pennsylvania 18034 Re: K242762 Trade/Device Name: Aesculap Aicon® Series Container System Regulation Number: 21 CFR 880.6850 Regulation Name: Sterilization Wrap Regulatory Class: Class II Product Code: KCT Dated: September 12, 2024 Received: April 10, 2025 Dear Hamza Ahmed: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K242762 - Hamza Ahmed Page 2 (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). {2} K242762 - Hamza Ahmed Page 3 Sincerely, Stephen A. Anisko -S Digitally signed by Stephen A. Anisko -S Date: 2025.05.13 16:20:02 -04'00' for: Christopher K. Dugard, M.S. Director DHT4C: Division of Infection Control Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2023 See PRA Statement below. 510(k) Number (if known) K242762 Device Name Aesculap Aicon® Series Container System Indications for Use (Describe) The AESCULAP Aicon® Container is a reusable rigid sterilization container intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device during transport and until used. This container is compatible for use in the following sterilization modalities in the configurations listed below: - Ethylene Oxide (EtO) - STERIS V-PRO maX/maX 2: Lumen, Non-Lumen, Flex - STERIS V-PRO 60: Lumen, Non-Lumen, Flex - STERIS V-PRO S2 Non-Lumen - STERRAD 100NX: Standard, Express, Flex, Duo - STERRAD NX: Standard, Advanced - STERRAD 100S - STERIZONE VP4 - PreVac Steam The AESCULAP Aicon® consists of two different container styles: a solid bottom container and enhance drying system (EDS) container. The AESCULAP Aicon® Container is compatible with accessories such as baskets, trays, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders, and tags. Prevac cycles without dry times are Immediate Use Sterilization Cycles (IUSS). The following tables identify the load configurations. Table 1. AESCULAP Aicon® Container Lumen Configurations | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | Ethylene Oxide (EtO) (130°F, 60 minute exposure 50-70% RH, concentration 735mg/L) | If including silicone, stainless steel, or no IOS: | Full Size | (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) | | | | Three-Quarter Size | (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) | | | | Half Size | (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) | | STERIS V-PRO maX /maX 2 Lumen Cycle | Only stainless steel or no IOS: | Full Size | (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) | | | | Three-Quarter Size | (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) | | | | Half Size | (12) Stainless Steel Lumens (≥1mm ID x ≤ 150mm L) | | STERIS V-PRO Max/ Max 2 Non-Lumen Cycle | If including silicone, stainless steel, or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Half Size | Non lumened stainless steel instruments | | STERIS V-PRO maX / maX 2 Flex Cycle | Only stainless steel or no IOS: | Full Size | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible | FORM FDA 3881 (6/20) Page 1 of 13 PSC Publishing Services (301) 443-6740 {4} | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | | | | endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | | | | Three-Quarter Size | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | | | | Half Size | (2) Flexible endoscopes with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L or two lumens with one ≥ 1 mm ID and ≤ 990 mm L and the other ≥ 1 mm ID and ≤ 850 mm L OR (1) flexible endoscope with a light cord (if not integral to endoscope) and additional non-lumened instruments. The flexible endoscope can have: a single lumen that is ≥ 1mm ID and ≤ 1050 L or two lumens with one ≥ 1 mm ID and ≤ 990 L and the other ≥ 1 mm ID and ≤ 850 mm L | | STERIS VPRO 60 Lumen Cycle | Only stainless steel or no IOS: | Full Size | (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) | | | | Three-Quarter Size | (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) | | | | Half Size | (12) Stainless Steel Lumens (≥1mm ID x ≤ 150mm L) | | STERIS VPRO 60 Non-Lumen Cycle | If including silicone, stainless steel, or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Half Size | Non lumened stainless steel instruments | | STERIS VPRO 60 Flex Cycle | Only stainless steel or no IOS: | Full Size | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L) | | | | Three-Quarter Size | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L) | | | | Half Size | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen or dual lumens (≥1mm ID x ≤990mm L) | | STERIS VPRO S2 Non-Lumen Cycle | If including silicone, stainless steel, or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Half Size | Non lumened stainless steel instruments | | STERRAD 100NX Standard Cycle | Only stainless steel or no IOS: | Full Size | (5) Stainless-Steel Lumens (≥1.0mm ID x ≤500mm L) (5) Stainless-Steel Lumens (≥0.7mm ID x ≤400mm L) | | | | Three-Quarter Size | (5) Stainless-Steel Lumens (≥1.0mm ID x ≤500mm L) (5) Stainless-Steel Lumens (≥0.7mm ID x ≤400mm L) | | | | Half Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤250mm L) (5) Stainless-Steel Lumens (≥0.7mm ID x ≤200mm L) | | | If including silicone IOS: | Full Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤500mm L) | | | | Three-Quarter Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤500mm L) | | | | Half Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤250mm L) | | STERRAD 100S | Only stainless steel or no IOS: | Full Size | (5) Stainless Steel Lumens (≥3.0mm 1.D. x ≤ 400mm L) | | | | Three-Quarter Size | (5) Stainless Steel Lumens (≥3.0mm 1.D. x ≤ 400mm L) | | | | Half Size | (5) Stainless Steel Lumens (≥2.0mm ID x ≤ 250mm L) | | | If including silicone IOS: | Full Size | (5) Stainless Steel Lumens (≥3mm 1.D. x ≤ 400mm L) | | | | Three-Quarter Size | (5) Stainless Steel Lumens (≥3mm 1.D. x ≤ 400mm L) | | | | Half Size | (5) Stainless Steel Lumens (≥3mm ID x ≤ 250mm L) | FORM FDA 3881 (6/20) Page 2 of 13 PSC Publishing Services (301) 443-6740 {5} | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | STERRAD NX Standard Cycle | Only stainless steel or no IOS: | Full Size | (10) Stainless-steel lumens (≥2.5mm ID x ≤ 400mm L) | | | | Three-Quarter Size | (10) Stainless-steel lumens (≥2.5mm ID x ≤ 400mm L) | | | | Half Size | (10) Stainless-steel lumens (≥2mm ID x ≤ 200mm L) | | | If including silicone IOS: | Full Size | (5) Stainless-Steel Lumens (≥2mm ID x ≤400mm L) | | | | Three-Quarter Size | (5) Stainless-Steel Lumens (≥2mm ID x ≤400mm L) | | | | Half Size | (5) Stainless-Steel Lumens (≥2mm ID x ≤250mm L) | | STERRAD NX Advanced Cycle | Only stainless steel or no IOS: | Full Size | (5) Stainless-steel lumens (≥2.5mm ID x ≤500mm L) | | | | | (5) Flexible Lumens (≥1mm ID x ≤850mm L) | | | | Three-Quarter Size | (5) Stainless-steel lumen (≥2.5mm ID x ≤500mm L) | | | | Half Size | (5) Flexible Lumens (≥1mm ID x ≤850mm L) | | STERRAD 100NX Express Cycle | Only stainless steel or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Full Size | Non lumened stainless steel instruments | | STERRAD 100NX DUO Cycle | Only stainless steel or no IOS: | Full Size | (1) Flexible Lumen (≥1mm ID x ≤ 850mm L) | | | | Three-Quarter Size | (1) Flexible Lumen (≥1mm ID x ≤ 850mm L) | | | | Half Size | (1) Flexible Lumen (≥1.mm ID x ≤ 650mm L) | | STERRAD 100NX Flex Cycle | Only stainless steel or no IOS: | Full Size | (1) Flexible Lumen(≥1.5mm ID x ≤ 650mm L) | | | | Three-Quarter Size | (1) Flexible Lumen (≥1.5mm ID x ≤ 650mm L) | | | | Half Size | (1) Flexible lumen (≥1.mm ID x ≤ 650mm L) | | PreVac Steam with dry time (270°F, 4 min Exposure) | If including silicone, stainless steel, or no IOS: | Full Size | (4) Stainless Steel Lumens (≥1.mm ID x ≤200mm L) | | | | Three-Quarter | (4) Stainless Steel Lumens (≥1.0mm ID x ≤200mm L) | | | | Half Size | (4) Stainless Steel Lumens (≥1.0mm ID x ≤200mm L) | | PreVac Steam without dry time (270°F, 4 min Exposure) Porous | If including silicone, stainless steel, or no IOS: | Full Size | (4) Stainless Steel Lumens (≥1mm ID x ≤ 125 mm L) | | | | Three-Quarter Size | (4) Stainless Steel Lumens (≥1mm ID x ≤ 125 mm L) | | | | Half Size | (4) Stainless Steel Lumens (≥1mm ID x ≤ 125 mm L) | | Prevac Steam without dry time (270°F, 3 min Exposure) Non-Porous | If including silicone, stainless steel, or no IOS: | Full Size | Non-lumened instruments | | | | Three-Quarter Size | Non-lumened instruments | | | | Half Size | Non-lumened instruments | | STERIZONE VP4 Load 8 (Aicon Validated Load 1) | Only stainless steel or no IOS: | Full Size | (1) Dual channel flexible scope (≥1.5mm ID x ≤850mm L) and (≥1.5mm ID x ≤989mm L) (1) Single channel flexible scope (≥1.5mm ID x ≤850mm L) | | | | Three-Quarter Size | (1) Dual channel flexible scope (≥1.5mm ID x ≤850mm L) and (≥1.5mm ID x ≤989mm L) (1) Single channel flexible scope (≥1.5mm ID x ≤850mm L) | | | | Half Size | (1) Dual channel flexible scope (≥1.5mm ID x ≤850mm L) and (≥1.5mm ID x ≤989mm L) (1) Single channel flexible scope (≥1.5mm ID x ≤850mm L) | | STERIZONE VP4 Load 4 (Aicon Validated Load 2) | Only stainless steel or no IOS: | Full Size | (1) Dual channel semi rigid scope (≥0.7mm ID x 500mm L; ≥1.1mm ID x ≤500mm L) (1) Dual channel semi rigid scope (≥1.1 mm ID x 500mm L; ≥1.1 mm ID x ≤500mm L) (2) Stainless Steel Lumens (≥2mm ID x ≤250mm L) (2) Stainless Steel Lumens (≥3mm ID x ≤400mm L) | | | | Three-Quarter Size | (1) Dual channel semi rigid scope (≥0.7mm ID x 500mm L; ≥1.1mm ID x ≤500mm L) (1) Dual channel semi rigid scope (≥1.1 mm ID x | FORM FDA 3881 (6/20) Page 3 of 13 PSC Publishing Services (301) 443-6740 {6} | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | | | | 500mm L; ≥1.1 mm ID x ≤500mm L) (2) Stainless Steel Lumens (≥2mm ID x ≤250mm L) (2) Stainless Steel Lumens (≥3mm ID x ≤400mm L) | | | | Half Size | (1) Stainless Steel Lumen (≥0.7 mm ID x ≤300mm L) (1) Stainless Steel Lumen (≥1.0 mm ID x ≤300mm L) (2) Stainless Steel Lumens (≥2.0 mm ID x ≤250mm L) (2) Stainless Steel Lumens (≥3.0 mm ID x ≤300mm L) | | STERIZONE VP4 Load 7 (Aicon Validated Load 3) | Only stainless steel or no IOS: | Full Size | Non-Lumened Stainless Steel Instruments (including hinges, luerlocks) | | | | Three-Quarter Size | Non-Lumened Stainless Steel Instruments (including hinges, luerlocks) | | | | Half Size | Non-Lumened Stainless Steel Instruments (including hinges, luerlocks) | FORM FDA 3881 (6/20) Page 4 of 13 PSC Publishing Services (301) 443-6740 {7} Table 2. AESCULAP Aicon® Container Configurations | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | EtO (130°F, 60 minute exposure 50-70% RH, concentration 735mg/L) | Full Size 4" | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 25 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIS VPRO maX / maX 2 Lumen | Full Size 4" | JJ110 | JJ111 | JJ410 | 19.65 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 19.65 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 13.8 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIS VPRO maX / maX 2 Non-Lumen | Full Size 4" | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 18.72 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 13.92 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIS VPRO maX / maX 2 Flex | Full Size 4" | JJ110 | JJ111 | JJ410 | (1) Flexible endoscope with a light cord (if not integral to | Only Stainless Steel IOS Compatible | FORM FDA 3881 (6/20) Page 5 of 13 PSC Publishing Services (301) 443-6740 {8} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Full Size 6" | JJ120 | JJ121 | | endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | (2) Flexible endoscopes with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L or two lumens with one ≥ 1 mm ID and ≤ 990 mm L and the other ≥ 1 mm ID and ≤ 850 mm L OR (1) flexible | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | FORM FDA 3881 (6/20) Page 6 of 13 PSC Publishing Services (301) 443-6740 {9} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Half Size 10" | JJ240 | JJ241 | | endoscope with a light cord (if not integral to endoscope) and additional non-lumened instruments (24lbs). The flexible endoscope can have: a single lumen that is ≥ 1mm ID and ≤ 1050 L or two lumens with one ≥ 1 mm ID and ≤ 990 L and the other ≥ 1 mm ID and ≤ 850 mm L | | | STERIS VPRO 60 Lumen | Full Size 4" | JJ110 | JJ111 | JJ410 | 11 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 11 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 11 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIS VPRO 60 Non-Lumen | Full Size 4" | JJ110 | JJ111 | JJ410 | 12 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 12 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 12 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | FORM FDA 3881 (6/20) Page 7 of 13 PSC Publishing Services (301) 443-6740 {10} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | STERIS VPRO 60 Flex | Full Size 4" | JJ110 | JJ111 | JJ410 | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L ) | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L ) | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L ) | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIS VPRO S2 Non-Lumen | Full Size 4" | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 18.7 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | Half Size 10" | JJ240 | JJ241 | | | | | | STERRAD 100NX Standard | Full Size 4" | JJ110 | JJ111 | JJ410 | 21.4 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 21.4 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | FORM FDA 3881 (6/20) Page 8 of 13 PSC Publishing Services (301) 443-6740 {11} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | STERAD 100S | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 13.8 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERAD NX Standard | Full Size 4" | JJ110 | JJ111 | JJ410 | 13.9 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 13.9 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 13.9 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERAD NX Advanced | Full Size 4" | JJ110 | JJ111 | JJ410 | 10.7 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 10.7 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 10.7 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERAD 100NX Express | Full Size 4" | JJ110 | JJ111 | JJ410 | 10.7 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 10.7 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 10.7 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | FORM FDA 3881 (6/20) Page 9 of 13 PSC Publishing Services (301) 443-6740 {12} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | STERRAD 100NX DUO | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 10.7 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 10.7 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERRAD 100NX Flex | Full Size 4" | JJ110 | JJ111 | JJ410 | 13.2 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 13.2 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 6.0 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERRAD 100NX Slicone mat and lid cover* 30 minute dry time Without silicone mat and lid cover* 20 minute dry time | Full Size 4" | JJ110 | JJ111 | JJ410 | 14.7 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 14.7 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 10.7 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | Prevac Steam 270°F, 4 min exposure With silicone mat and lid cover* 30 minute dry time Without silicone mat and lid cover* 20 minute dry time | Full Size 4" | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | 24 | | | | Full Size 8" | JJ130 | JJ131 | | 23 | | | | Full Size 10" | JJ140 | JJ141 | | 22 | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 23 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | 22 | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | 20 | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | 18 | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 18 | | | | Half Size 6" | JJ220 | JJ221 | | 18 | | | | Half Size 8" | JJ230 | JJ231 | | 15 | | | | Half Size 10" | JJ240 | JJ241 | | 13 | | | PreVac Steam without dry time | Full Size 4" | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel | | | Full Size 6" | JJ120 | JJ121 | | | | FORM FDA 3881 (6/20) Page 10 of 13 PSC Publishing Services (301) 443-6740 {13} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | 270°F 3 min Exposure (Non-porous) AND Prevac Steam without dry time 270°F 4 min Exposure (Porous) | Full Size 8" | JJ130 | JJ131 | | | IOS Compatible | | | Full Size 10" | JJ140 | JJ141 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 25 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | Half Size 10" | JJ240 | JJ241 | | | | | | STERIZONE VP4 Based on Sterizone Validated Load 8 (Aicon Validated Load 1) | Full Size 4" | JJ110 | JJ111 | JJ410 | Based on Load Configuration in Table 1 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | Based on Load Configuration in Table 1 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | Based on Load Configuration in Table 1 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIZONE VP4 Based on Sterizone Validated Load 4 (Aicon Validated Load 2) | Full Size 4" | JJ110 | JJ111 | JJ410 | Based on Load Configuration in Table 1 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | Based on Load Configuration in Table 1 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | Based on Load Configuration in Table 1 | | | | Half Size 6" | JJ220 | JJ221 | | | | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | | STERIZONE VP4 Based on Sterizone Validated Load 7 (Aicon Validated Load 3) | Full Size 4" | JJ110 | JJ111 | JJ410 | 25 | Only Stainless Steel IOS Compatible | | | Full Size 6" | JJ120 | JJ121 | | | | | | Full Size 8" | JJ130 | JJ131 | | | | | | Three-Quarter Size 4" | JJ310 | JJ311 | JJ430 | 25 | | | | Three-Quarter Size 6" | JJ320 | JJ321 | | | | | | Three-Quarter Size 8" | JJ330 | JJ331 | | | | | | Three-Quarter Size 10" | JJ340 | JJ341 | | | | | | Half Size 4" | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6" | JJ220 | JJ221 | | | | FORM FDA 3881 (6/20) Page 11 of 13 PSC Publishing Services (301) 443-6740 {14} | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Half Size 8" | JJ230 | JJ231 | | | | | | Half Size 10" | JJ240 | JJ241 | | | | * Silicone mats and/or lid covers may require a longer drying time when used in PreVac Steam Sterilization. Table 3: AESCULAP Aicon® Container Sterilization Cycle Compatible Accessories | Accessories | | EtO | Steris V-PRO Systems | STERRAD Systems | STERIZONE VP4 | PREVAC STEAM | | --- | --- | --- | --- | --- | --- | --- | | Baskets, trays, indicator cards, tamper evident locks, faceplate holders, and tags. | | Yes | Yes | Yes | Yes | Yes | | Instrument Organization System (IOS) (Stainless Steel racks, brackets, holders, and clamps) | Without Silicone | Yes | Yes | Yes | Yes | Yes | | | With Silicone | Yes | See Table 2 | See Table 2 | No | Yes | | Silicone mats | | No | No | No | No | Yes* | | Lid Covers | | No | No | No | No | Yes* | * Use of silicone mats and/or lid covers may require a longer drying time. Type of Use (Select one or both, as applicable) ☐ Prescription Use (Part 21 CFR 801 Subpart D) ☑ Over-The-Counter Use (21 CFR 801 Subpart C) CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. "DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW." The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services FORM FDA 3881 (6/20) Page 12 of 13 PSC Publishing Services (301) 443-6740 {15} Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." FORM FDA 3881 (6/20) Page 13 of 13 PSC Publishing Services (301) 443-6740 {16} K242762 # 510(k) SUMMARY (as required by 21 CFR 807.92) | COMPANY: | Aesculap, Inc. 3773 Corporate Parkway Center Valley, PA 18034 Establishment Registration Number: 2916714 | | --- | --- | | CONTACT: | Hamza Ahmed hamza.ahmed@bbraunusa.com (610) 737-3900 (901) 832-7486 610-791-6882 (fax) | | Date Prepared: | May 6, 2025 | | TRADE NAME: | Aesculap Aicon® Series Container System | | COMMON NAME: | Sterilization Container Wrap | | CLASSIFICATION NAME: | Wrap, Sterilization | | REGULATION NUMBER: | 880.6850 | | PRODUCT CODE: | KCT | | DEVICE CLASS: | Class II per 21 CFR 880.6850 | # PREDICATE DEVICE - Primary predicate: Aicon® JJ Series Container for low temperature sterilization (K214041). - Reference Device: Aicon® JJ Series Container for PreVac Steam sterilization (K192056) # DEVICE DESCRIPTION The AESCULAP Aicon® Container System is a reusable rigid container system used for the packaging, transportation, and storage of instruments prior to, during, and after sterilization. It consists of the various sizes of container bottoms, container lid, and basket options, and should only be used with designated Aesculap® filters, locks and indicator cards identified in this IFU. The AESCULAP Aicon® Container System is provided non-sterile and will undergo sterilization by the end user. The AESCULAP Aicon® Container System can be identified by its JJ Series part number. - The first digit of the model number designates the container length. - The second digit designates the height. - The last digit identifies the model and features. o Standard solid bottom container, designated by the "0" at the end of the product number. o Enhanced Drying System (EDS) solid bottom container, designated by the "1" at the end of the product number. The EDS container can also be identified by the Enhanced Drying Module, item 14 in the Product Component Diagram. {17} K242762 - The JJ Series uses the same lids for the Standard and the EDS container bottoms. | Container Size | Standard Container | EDS Container | Lid | | --- | --- | --- | --- | | Full Size 4” | JJ110 | JJ111 | JJ410 | | Full Size 6” | JJ120 | JJ121 | | | Full Size 8” | JJ130 | JJ131 | | | Full Size 10” | JJ140 | JJ141 | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | | Three-Quarter Size 6” | JJ320 | JJ321 | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | Half Size 4” | JJ210 | JJ211 | JJ420 | | Half Size 6” | JJ220 | JJ221 | | | Half Size 8” | JJ230 | JJ231 | | | Half Size 10” | JJ240 | JJ241 | | The AESCULAP Aicon® Container System lid latches should remain in the closed position at all times except when installing on and removing the lid from the container bottom. The JJ Series can be used with the perforated baskets and trays of both the AESCULAP Aicon® Container System and Aesculap® SterilContainer™ System. Non-Aesculap® pre-configured baskets that meet the clearance requirements, and can be properly aseptically presented may also be used. Medical device and container IFUs parameters (time and temperature) should be reconciled. Steam sterilization dry time performance may vary by facility based on water and steam quality and/or sterilization performance. Ensure you can achieve the same end result as identified in the instrument IFU. Follow facilities policies and procedures. **Notes:** - Thoroughly clean all Aesculap® container products, baskets, accessories and replacement parts prior to first use and after container repair service has been performed. - Aesculap® baskets and accessories can be cleaned and sterilized following accepted industry guidelines and by using the same processes as Aesculap® sterile container bottoms. - AESCULAP Aicon® Container System has ONLY been validated with Aesculap® filters, locks and indicator cards. - Aesculap® only performed container testing with baskets and does not recommend using containers without baskets or with only mats. {18} K242762 # INDICATIONS FOR USE The AESCULAP Aicon® Container is a reusable rigid sterilization container intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device during transport and until used. This container is compatible for use in the following sterilization modalities in the configurations listed below: - Ethylene Oxide (EtO) - STERIS V-PRO maX/maX 2: Lumen, Non-Lumen, Flex - STERIS V-PRO 60: Lumen, Non-Lumen, Flex - STERIS V-PRO S2 Non-Lumen - STERRAD 100NX: Standard, Express, Flex, Duo - STERRAD NX: Standard, Advanced - STERRAD 100S - STERIZONE VP4 - PreVac Steam The AESCULAP Aicon® consists of two different container styles: a solid bottom container and enhance drying system (EDS) container. The AESCULAP Aicon® Container is compatible with accessories such as baskets, trays, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders, and tags. Prevac cycles without dry times are Immediate Use Sterilization Cycles (IUSS). The following tables identify the load configurations. Table 1. AESCULAP Aicon® Container Lumen Configurations | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | Ethylene Oxide (EtO) (130°F, 60 minute exposure 50-70% RH, concentration 735mg/L) | If including silicone, stainless steel, or no IOS: | Full Size | (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) | | | | Three-Quarter Size | (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) | | | | Half Size | (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L) | | STERIS V-PRO maX /maX 2 Lumen Cycle | Only stainless steel or no IOS: | Full Size | (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) | | | | Three-Quarter Size | (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L) (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L) | | | | Half Size | (12) Stainless Steel Lumens (≥1mm ID x ≤ 150mm L) | | STERIS V-PRO Max/ Max 2 Non-Lumen Cycle | If including silicone, stainless steel, or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Half Size | Non lumened stainless steel instruments | | STERIS V-PRO maX / maX 2 Flex Cycle | Only stainless steel or no IOS: | Full Size | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | {19} K242762 | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | | | Three-Quarter Size | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | | | | Half Size | (2) Flexible endoscopes with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L or two lumens with one ≥1 mm ID and ≤990 mm L and the other ≥1 mm ID and ≤850 mm L OR(1) flexible endoscope with a light cord (if not integral to endoscope) and additional non-lumened instruments. The flexible endoscope can have: a single lumen that is ≥1mm ID and ≤1050 L or two lumens with one ≥1 mm ID and ≤990 L and the other ≥1 mm ID and ≤850 mm L | | STERIS VPRO 60 Lumen Cycle | Only stainless steel or no IOS: | Full Size | (6) Stainless Steel Lumens (≥1mm ID x ≤400mm L)(6) Stainless Steel Lumens (≥0.77mm ID x ≤250mm L) | | | | Three-Quarter Size | (6) Stainless Steel Lumens (≥1mm ID x ≤400mm L)(6) Stainless Steel Lumens (≥0.77mm ID x ≤250mm L) | | | | Half Size | (12) Stainless Steel Lumens (≥1mm ID x ≤150mm L) | | STERIS VPRO 60 Non-Lumen Cycle | If including silicone, stainless steel, or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Half Size | Non lumened stainless steel instruments | | STERIS VPRO 60 Flex Cycle | Only stainless steel or no IOS: | Full Size | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L) | | | | Three-Quarter Size | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L) | | | | Half Size | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen or dual lumens (≥1mm ID x ≤990mm L) | | STERIS VPRO S2 Non-Lumen Cycle | If including silicone, stainless steel, or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Half Size | Non lumened stainless steel instruments | | STERRAD 100NX Standard Cycle | Only stainless steel or no IOS: | Full Size | (5) Stainless-Steel Lumens (≥1.0mm ID x ≤500mm L)(5) Stainless-Steel Lumens (≥0.7mm ID x ≤400mm L) | | | | Three-Quarter Size | (5) Stainless-Steel Lumens (≥1.0mm ID x ≤500mm L)(5) Stainless-Steel Lumens (≥0.7mm ID x ≤400mm L) | | | | Half Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤250mm L)(5) Stainless-Steel Lumens (≥0.7mm ID x ≤200mm L) | | | | Full Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤500mm L) | {20} K242762 | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | | If including silicone IOS: | Three-Quarter Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤500mm L) | | | | Half Size | (5) Stainless-Steel Lumens (≥0.7mm ID x ≤250mm L) | | STERRAD 100S | Only stainless steel or no IOS: | Full Size | (5) Stainless Steel Lumens (≥3.0mm 1.D. x ≤ 400mm L) | | | | Three-Quarter Size | (5) Stainless Steel Lumens (≥3.0mm 1.D. x ≤ 400mm L) | | | | Half Size | (5) Stainless Steel Lumens (≥2.0mm ID x ≤ 250mm L) | | | If including silicone IOS: | Full Size | (5) Stainless Steel Lumens (≥3mm 1.D. x ≤ 400mm L) | | | | Three-Quarter Size | (5) Stainless Steel Lumens (≥3mm 1.D. x ≤ 400mm L) | | | | Half Size | (5) Stainless Steel Lumens (≥3mm ID x ≤ 250mm L) | | STERRAD NX Standard Cycle | Only stainless steel or no IOS: | Full Size | (10) Stainless-steel lumens (≥2.5mm ID x ≤ 400mm L) | | | | Three-Quarter Size | (10) Stainless-steel lumens (≥2.5mm ID x ≤ 400mm L) | | | | Half Size | (10) Stainless-steel lumens (≥2mm ID x ≤ 200mm L) | | | If including silicone IOS: | Full Size | (5) Stainless-Steel Lumens (≥2mm ID x ≤400mm L) | | | | Three-Quarter Size | (5) Stainless-Steel Lumens (≥2mm ID x ≤400mm L) | | | | Half Size | (5) Stainless-Steel Lumens (≥2mm ID x ≤250mm L) | | STERRAD NX Advanced Cycle | Only stainless steel or no IOS: | Full Size | (5) Stainless-steel lumens (≥2.5mm ID x ≤500mm L) (5) Flexible Lumens (≥1mm ID x ≤850mm L) | | | | Three-Quarter Size | (5) Stainless-steel lumen (≥2.5mm ID x ≤500mm L) (5) Flexible Lumens (≥1mm ID x ≤850mm L) | | | | Half Size | (10) Stainless-steel lumens (≥2mm ID x ≤ 200mm L) | | STERRAD 100NX Express Cycle | Only stainless steel or no IOS: | Full Size | Non lumened stainless steel instruments | | | | Three-Quarter Size | Non lumened stainless steel instruments | | | | Full Size | Non lumened stainless steel instruments | | STERRAD 100NX DUO Cycle | Only stainless steel or no IOS: | Full Size | (1) Flexible Lumen (≥1mm ID x ≤ 850mm L) | | | | Three-Quarter Size | (1) Flexible Lumen (≥1mm ID x ≤ 850mm L) | | | | Half Size | (1) Flexible Lumen (≥1.mm ID x ≤ 650mm L) | | STERRAD 100NX Flex Cycle | Only stainless steel or no IOS: | Full Size | (1) Flexible Lumen(≥1.5mm ID x ≤ 650mm L) | | | | Three-Quarter Size | (1) Flexible Lumen (≥1.5mm ID x ≤ 650mm L) | | | | Half Size | (1) Flexible lumen (≥1.mm ID x ≤ 650mm L) | | PreVac Steam with dry time (270°F, 4 min Exposure) | If including silicone, stainless steel, or no IOS: | Full Size | (4) Stainless Steel Lumens (≥1.mm ID x ≤200mm L) | | | | Three-Quarter | (4) Stainless Steel Lumens (≥1.0mm ID x ≤200mm L) | | | | Half Size | (4) Stainless Steel Lumens (≥1.0mm ID x ≤200mm L) | | PreVac Steam without dry time (270°F, 4 min Exposure) Porous | If including silicone, stainless steel, or no IOS: | Full Size | (4) Stainless Steel Lumens (≥1mm ID x ≤ 125 mm L) | | | | Three-Quarter Size | (4) Stainless Steel Lumens (≥1mm ID x ≤ 125 mm L) | | | | Half Size | (4) Stainless Steel Lumens (≥1mm ID x ≤ 125 mm L) | | Prevac Steam without dry time (270°F, 3 min Exposure) Non-Porous | If including silicone, stainless steel, or no IOS: | Full Size | Non-lumened instruments | | | | Three-Quarter Size | Non-lumened instruments | | | | Half Size | Non-lumened instruments | | STERIZONE VP4 Load 8 | Only stainless steel or no IOS: | Full Size | (1) Dual channel flexible scope (≥1.5mm ID x ≤850mm L) and (≥1.5mm ID x ≤989mm L) | 5 {21} K242762 | Sterilization Cycle | IOS Configuration | Container Sizes | Compatible Lumens | | --- | --- | --- | --- | | (Aicon Validated Load 1) | | | (1) Single channel flexible scope (≥1.5mm ID x ≤850mm L) | | | | Three-Quarter Size | (1) Dual channel flexible scope (≥1.5mm ID x ≤850mm L) and (≥1.5mm ID x ≤989mm L) (1) Single channel flexible scope (≥1.5mm ID x ≤850mm L) | | | | Half Size | (1) Dual channel flexible scope (≥1.5mm ID x ≤850mm L) and (≥1.5mm ID x ≤989mm L) (1) Single channel flexible scope (≥1.5mm ID x ≤850mm L) | | STERIZONE VP4 Load 4 (Aicon Validated Load 2) | Only stainless steel or no IOS: | Full Size | (1) Dual channel semi rigid scope (≥0.7mm ID x 500mm L; ≥1.1mm ID x ≤500mm L) (1) Dual channel semi rigid scope (≥1.1 mm ID x 500mm L; ≥1.1 mm ID x ≤500mm L) (2) Stainless Steel Lumens (≥2mm ID x ≤250mm L) (2) Stainless Steel Lumens (≥3mm ID x ≤400mm L) | | | | Three-Quarter Size | (1) Dual channel semi rigid scope (≥0.7mm ID x 500mm L; ≥1.1mm ID x ≤500mm L) (1) Dual channel semi rigid scope (≥1.1 mm ID x 500mm L; ≥1.1 mm ID x ≤500mm L) (2) Stainless Steel Lumens (≥2mm ID x ≤250mm L) (2) Stainless Steel Lumens (≥3mm ID x ≤400mm L) | | | | Half Size | (1) Stainless Steel Lumen (≥0.7 mm ID x ≤300mm L) (1) Stainless Steel Lumen (≥1.0 mm ID x ≤300mm L) (2) Stainless Steel Lumens (≥2.0 mm ID x ≤250mm L) (2) Stainless Steel Lumens (≥3.0 mm ID x ≤300mm L) | | STERIZONE VP4 Load 7 (Aicon Validated Load 3) | Only stainless steel or no IOS: | Full Size | Non-Lumened Stainless Steel Instruments (including hinges, luerlocks) | | | | Three-Quarter Size | Non-Lumened Stainless Steel Instruments (including hinges, luerlocks) | | | | Half Size | Non-Lumened Stainless Steel Instruments (including hinges, luerlocks) | 6 {22} K242762 Table 2. AESCULAP Aicon® Container Configurations | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | EtO (130°F, 60 minute exposure 50-70% RH, concentration 735mg/L) | Full Size 4” | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 25 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIS VPRO maX / maX 2 Lumen | Full Size 4” | JJ110 | JJ111 | JJ410 | 19.65 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 19.65 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 13.8 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIS VPRO maX / maX 2 Non-Lumen | Full Size 4” | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 18.72 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 13.92 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | {23} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | STERIS VPRO maX / maX 2 Flex | Full Size 4” | JJ110 | JJ111 | JJ410 | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | (1) Flexible endoscope with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | (2) Flexible endoscopes with a light cord (if not integral to endoscope) without any additional load. The flexible endoscope may be single lumen that is ≥1mm ID x ≤1050mm L or two lumens | | | | Half Size 6” | JJ220 | JJ221 | | | | 8 {24} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Half Size 8” | JJ230 | JJ231 | | with one ≥ 1 mm ID and ≤ 990 mm L and the other ≥ 1 mm ID and ≤ 850 mm L OR (1) flexible endoscope with a light cord (if not integral to endoscope) and additional non-lumened instruments (24lbs). The flexible endoscope can have: a single lumen that is ≥ 1mm ID and ≤ 1050 L or two lumens with one ≥ 1 mm ID and ≤ 990 L and the other ≥ 1 mm ID and ≤ 850 mm L | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIS VPRO 60 Lumen | Full Size 4” | JJ110 | JJ111 | JJ410 | 11 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 11 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 11 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIS VPRO 60 Non-Lumen | Full Size 4” | JJ110 | JJ111 | JJ410 | 12 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | 9 {25} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | STERIS VPRO 60 Flex | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 12 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 12 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIS VPRO 60 Flex | Full Size 4” | JJ110 | JJ111 | JJ410 | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L ) | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L ) | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | (1) flexible surgical endoscope or bronchoscope with a light cord (if not integral to scope) and single lumen (≥1mm ID x ≤990mm L ) | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIS VPRO S2 Non-Lumen | Full Size 4” | JJ110 | JJ111 | JJ410 | 25 | | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | 10 {26} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 18.7 | Silicone and Stainless Steel IOS Compatible | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD 100NX Standard | Full Size 4” | JJ110 | JJ111 | JJ410 | 21.4 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 21.4 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 13.8 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD 100S | Full Size 4” | JJ110 | JJ111 | JJ410 | 13.9 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 13.9 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 13.9 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD NX Standard | Full Size 4” | JJ110 | JJ111 | JJ410 | 10.7 | Silicone and Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 10.7 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | | | | 11 {27} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Half Size 6” | JJ220 | JJ221 | JJ420 | 10.7 | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD NX Advanced | Full Size 4” | JJ110 | JJ111 | JJ410 | 10.7 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 10.7 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 10.7 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD 100NX Express | Full Size 4” | JJ110 | JJ111 | JJ410 | 10.7 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 10.7 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 10.7 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD 100NX DUO | Full Size 4” | JJ110 | JJ111 | JJ410 | 13.2 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Full Size 10” | JJ140 | JJ141 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 13.2 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 6.0 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERRAD 100NX Flex | Full Size 4” | JJ110 | JJ111 | JJ410 | 14.7 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | 12 {28} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | Prevac Steam 270°F, 4 min exposure With silicone mat and lid cover* 30 minute dry time Without silicone mat and lid cover* 20 minute dry time | Full Size 10” | JJ140 | JJ141 | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 14.7 | | Three-Quarter Size 6” | JJ320 | JJ321 | | Three-Quarter Size 8” | JJ330 | JJ331 | | Three-Quarter Size 10” | JJ340 | JJ341 | | Half Size 4” | JJ210 | JJ211 | JJ420 | 10.7 | | Half Size 6” | JJ220 | JJ221 | | Half Size 8” | JJ230 | JJ231 | | Half Size 10” | JJ240 | JJ241 | | Prevac Steam 270°F, 4 min exposure With silicone mat and lid cover* 30 minute dry time Without silicone mat and lid cover* 20 minute dry time | Full Size 4” | JJ110 | JJ111 | JJ410 | 25 | Silicone and Stainless Steel IOS Compatible | | Full Size 6” | JJ120 | JJ121 | 24 | | Full Size 8” | JJ130 | JJ131 | 23 | | Full Size 10” | JJ140 | JJ141 | 22 | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 23 | | Three-Quarter Size 6” | JJ320 | JJ321 | 22 | | Three-Quarter Size 8” | JJ330 | JJ331 | 20 | | Three-Quarter Size 10” | JJ340 | JJ341 | 18 | | Half Size 4” | JJ210 | JJ211 | JJ420 | 18 | | Anth Prevac Steam without dry time 270°F 4 min Exposure (Porous) | Full Size 4” | JJ110 | JJ111 | JJ410 | 25 | | Full Size 6” | JJ120 | JJ121 | | Full Size 8” | JJ130 | JJ131 | | STERIZONE VP4 Based on Sterizone Validated Load 8 (Aicon Validated Load 1) | Full Size 10” | JJ140 | JJ141 | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 25 | Silicone and Stainless Steel IOS Compatible | | Three-Quarter Size 6” | JJ320 | JJ321 | | Three-Quarter Size 8” | JJ330 | JJ331 | | Three-Quarter Size 10” | JJ340 | JJ341 | | Half Size 4” | JJ210 | JJ211 | JJ420 | 25 | | Half Size 6” | JJ220 | JJ221 | | Half Size 8” | JJ230 | JJ231 | | Half Size 10” | JJ240 | JJ241 | 13 {29} K242762 | Sterilization Method | Container Size | Standard Container | EDS Container | Container Lid Part # | Total Loaded Container (lbs) | IOS Compatibility | | --- | --- | --- | --- | --- | --- | --- | | | Three-Quarter Size 8” | JJ330 | JJ331 | | 13.8lbs | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | Based on Load Configuration in Table 1 5.8lbs | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIZONE VP4 Based on Sterizone Validated Load 4 (Aicon Validated Load 2) | Full Size 4” | JJ110 | JJ111 | JJ410 | Based on Load Configuration in Table 1 11 7lbs | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | Based on Load Configuration in Table 1 11 7lbs | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | Based on Load Configuration in Table 1 5.8lbs | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | | STERIZONE VP4 Based on Sterizone Validated Load 7 (Aicon Validated Load 3) | Full Size 4” | JJ110 | JJ111 | JJ410 | 25 | Only Stainless Steel IOS Compatible | | | Full Size 6” | JJ120 | JJ121 | | | | | | Full Size 8” | JJ130 | JJ131 | | | | | | Three-Quarter Size 4” | JJ310 | JJ311 | JJ430 | 25 | | | | Three-Quarter Size 6” | JJ320 | JJ321 | | | | | | Three-Quarter Size 8” | JJ330 | JJ331 | | | | | | Three-Quarter Size 10” | JJ340 | JJ341 | | | | | | Half Size 4” | JJ210 | JJ211 | JJ420 | 25 | | | | Half Size 6” | JJ220 | JJ221 | | | | | | Half Size 8” | JJ230 | JJ231 | | | | | | Half Size 10” | JJ240 | JJ241 | | | | * Silicone mats and/or lid covers may require a longer drying time when used in PreVac Steam Sterilization. 14 {30} K242762 Table 3: AESCULAP Aicon® Container Sterilization Cycle Compatible Accessories | Accessories | | EtO | Steris V-PRO Systems | STERRAD Systems | STERIZONE VP4 | PREVAC STEAM | | --- | --- | --- | --- | --- | --- | --- | | Baskets, trays, indicator cards, tamper evident locks, faceplate holders, and tags. | | Yes | Yes | Yes | Yes | Yes | | Instrument Organization System (IOS) (Stainless Steel racks, brackets, holders, and clamps) | Without Silicone | Yes | Yes | Yes | Yes | Yes | | | With Silicone | Yes | See Table 2 | See Table 2 | No | Yes | | Silicone mats | | No | No | No | No | Yes* | | Lid Covers | | No | No | No | No | Yes* | * Use of silicone mats and/or lid covers may require a longer drying time. ## TECHNOLOGICAL CHARACTERISTICS (compared to predicate device) The table below provides a summary of the device technological characteristics comparing the subject device and predicate device. The subject device is offered in similar sizes and is comprised of similar materials of construction as the predicate device. The AESCULAP Aicon® Container has the same intended use as the Aesculap predicate device. | Characteristic | Subject Device Aesculap AICON® Series Container System (K242762) Product Code: KCT | Predicate Device - Aesculap JJ Series Container System (K214041) Product Code: KCT | Reference Device - Aesculap JJ Series Container System (K192056) Product Code: KCT | Discussion of similarities and differences | | --- | --- | --- | --- | --- | | Indications for Use | See indications for use section provided in eSTAR | Reference form 3881 in K214041 | Reference form 3881 in K192056 | Change to indications for use to allow usage of silicone instrument organization systems for some VHP modalities and designated Stainless Steel IOS for modalities which were already cleared in K214041. Revised table 1 and table 2 in the indications for use and added columns for filter compatibility and silicone accessories compatibility for a given modality. | {31} K242762 | | | | | Added additional line items for Sterrad 100S, Sterrad NX Standard, Sterrad 100 NX standard, Steris V-Pro max 2 Non-Lumen, V-PRO max Non-Lumen, V-PRO 60 Non-Lumen, and V-PRO S2 Non-Lumen for modified load configurations which incorporate usage of silicone IOS. Reduced lumen sizes were designated for modalities with Silicone IOS allowance in lumen cycles. | | --- | --- | --- | --- | --- | | Intended Use | A device intended to be used to enclose another medical device that is to be sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device and also to maintain sterility of the enclosed device until used. | A device intended to be used to enclose another medical device that is to be sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device and also to maintain sterility of the enclosed device until used. | A device intended to be used to enclose another medical device that is to be sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device and also to maintain sterility of the enclosed device until used. | Same | | Sterilization Modalities | Sterrad 100S Sterrad NX Standard Sterrad 100 NX Standard Steris V-Pro max 2 Non-Lumen V-PRO max Non-Lumen V-PRO 60 Non-Lumen V-PRO S2 Non-Lumen | Ethylene Oxide STERIS VPRO: 60 Lumen, 60 Non-Lumen, 60 Flex, maX Lumen, maX Non-Lumen, maX Flex STERRAD 100NX STERRAD 100NX FLEX STERRAD 100NX DUO cycle STERRAD 100NX EXPRESS cycle STERIZONE VP4 PreVac Steam with dry time | PreVac Steam with dry time Prevac Steam without dry time | Similar; Sterilization modalities of the subject device are comparable to the predicate device sterilization modalities | 16 {32} K242762 | | | PreVac Steam without dry time | | | | --- | --- | --- | --- | --- | | Material | Container: Anodized aluminum Lid: Anodized aluminum Gasket: Silicone | Container: Anodized aluminum Lid: Anodized aluminum Gasket: Silicone | Container: Anodized aluminum Lid: Anodized aluminum Gasket: Silicone | Same | | Filter Type | Single use (Polypropylene) | Single use (Polypropylene) | Single use (Paper) | Same | | Container Design | Solid bottom or Solid bottom with enhanced drying system with Perforated Lid | Solid bottom or Solid bottom with enhanced drying system with Perforated Lid | Solid bottom or Solid bottom with enhanced drying system with Perforated Lid | Same | | Sizes | Full size Three-Quarter Size Half Size | Full size Three-Quarter Size Half Size | Full size Three-Quarter Size Half Size | Same | | Accessories | Baskets, trays, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders and tags. | Baskets, trays, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders and tags (No Silicone Pieces) | Baskets, trays, silicone mats, instrument organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders and tags. | Same | | Sterility Shelf Life | 365 days | 365 days | 365 days | Same | 17 {33} K242762 # PERFORMANCE DATA AS REQUIRED BY 21 CFR 807.92 The table below provides a brief discussion of the non-clinical tests submitted, referenced, or relied on in the premarket notification submission to demonstrate device performance. Clinical testing is not required for this device. | Performance Testing | Purpose | Acceptance Criteria | Results | | --- | --- | --- | --- | | Sterilization Efficacy | To determine sterilization effectiveness of test device after processing in a sterilization cycle. | A sterility assurance level (SAL) of 10^{-6} will be achieved post sterilization using the BI overkill method and half cycle validation indicated in section 5.6 of AAMI ST-77. Biological indicators must be negative for growth after incubation period | Pass | | Dry Time | To determine the proper drying time required for the Aesculap Aicon Container. | Per AAMI ST-77 section 4.4.2, (in association with EN868-8 section G.3/G.4 and EN 285 section G20.3), the system shall demonstrate an average pre and post sterilization weight difference of less than 0.2% within five 5 minutes of cycle completion using final validated parameters and be free of visible moisture following a cooling period. | Pass | | Microbial Aerosol Challenge | To analyze the package integrity and microbial barrier properties of the test device. | The container load maintains sterility after exposure to a defined amount of aerosol microorganisms per ST-77 sections 5.9.1.1 & 5.9.1.2. No presence of growth after incubation period. | Pass | | Cytotoxicity | To determine the potential of a test device to cause cytotoxicity. | Testing completed in accordance with ISO 10993-5:2009. Using the ISO Elution Method, the response to the article must not be greater than 2 (mild reactivity). | Pass | | Simulated Use | To determine the effective sterilization of flexible scopes when used with the test device. | A minimum of 1.0 x 10^{6} spores contained within organic soil representative of actual use conditions are killed during defined sterilization cycle. | Pass | | Cleaning Validation | To verify the effectiveness of the device cleaning procedure. | In accordance with Annex A and section 7.5 of TIR30, test samples shall show no visible soil after cleaning and shall have protein or hemoglobin levels less than the predetermined amounts. | Pass | | Material Compatibility | To assess effects of full use cycles on device components and their intended functionality. | No degradation or impact to functionality at the completion multiple sterilization cycles according to section 5.0 of TIR17. | Pass | 18 {34} K242762 | Sterility Maintenance | To demonstrate that a processed test device can maintain a sterile barrier for a defined period of time. | Sterility of container contents is maintained under conditions which simulate hospital sterile package handling and storage conditions and were tested per ISO 11167-1 section 6.4. Test articles stored for their post processing shelf life. Biological indicators must be negative for growth after incubation period. | Pass | | --- | --- | --- | --- | Results of the testing demonstrates that the proposed device met the acceptance criteria for each performance test. # CONCLUSION The conclusions drawn from the nonclinical tests demonstrate that the subject device in $510(\mathrm{k})$ submission K242762, Aesculap Aicon® Container system, is as safe, as effective, and performs as well as or better than the legally marketed predicate device cleared in K214041. 19
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...