SLEEVED/SLEEVELESS VEST RESTRAINT
Device Facts
| Record ID | K963478 |
|---|---|
| Device Name | SLEEVED/SLEEVELESS VEST RESTRAINT |
| Applicant | Deroyal Industries, Inc. |
| Product Code | FMQ · General Hospital |
| Decision Date | Nov 14, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 880.6760 |
| Device Class | Class 1 |
Indications for Use
The DeRoyal Industries, Inc. Sleeved/ Sleeveless Vest Restraint is indicated for use, at the discretion of a responsible licensed healthcare professional, to limit movements thereby enabling examination or protection of the patient or others. The Sleeved/ Sleeveless Vest Restraint is a protective restraint that is intended to be used with a bed or wheelchair.
Device Story
Protective restraint device; limits patient movement to facilitate examination or ensure safety of patient/others. Used in clinical settings (beds/wheelchairs). Operated by healthcare professionals. Design consists of vest (sleeved/sleeveless) secured via straps to bed or wheelchair. Fastened using nylon hook/loop or steel nickel-plated buckles. Benefits include prevention of patient injury or interference with medical care.
Clinical Evidence
Bench testing only; no clinical data provided.
Technological Characteristics
Materials: tietex, cotton flannel, polyester cool knit, polyester twill tape, white webbing. Fasteners: nylon hook and loop or steel nickel-plated buckles. Sizes: XS to XXXL. Attachment: bed or wheelchair. Non-powered, mechanical device.
Indications for Use
Indicated for mildly to moderately agitated or disoriented patients requiring movement limitation for examination or protection of patient/others; used with bed or wheelchair; requires prescription by licensed healthcare professional every 24 hours.
Regulatory Classification
Identification
A protective restraint is a device, including but not limited to a wristlet, anklet, vest, mitt, straight jacket, body/limb holder, or other type of strap, that is intended for medical purposes and that limits the patient's movements to the extent necessary for treatment, examination, or protection of the patient or others.
Predicate Devices
- J.T. Posey Company
- DeRoyal Industries, Inc.
Related Devices
- K963470 — CRISS-CROSS VEST RESTRAINT · Deroyal Industries, Inc. · Nov 14, 1996
- K963471 — SUPER SECURITY RESTRAINT · Deroyal Industries, Inc. · Nov 14, 1996
- K972123 — PROTECTIVE RESTRAINT MODELS #302,440,750,850,AND905 · Smith · Jul 25, 1997
- K963474 — TUXEDO VEST RESTRAINT · Deroyal Industries, Inc. · Jan 22, 1997
- K963430 — PROTECTIVE RESTRAINT (VEST RESTRAINT) · Kenad SG Medical, Inc. · Nov 22, 1996