K963237 · Heelbo, Inc. · FMQ · Oct 9, 1996 · General Hospital
Device Facts
Record ID
K963237
Device Name
HEELBO ICU 911 BLAZER SLEEVED JACKET
Applicant
Heelbo, Inc.
Product Code
FMQ · General Hospital
Decision Date
Oct 9, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.6760
Device Class
Class 1
Indications for Use
The Heelbo ICU 911 Blazer Sleeved Jacket is intended to help support and help prevent a patient from slumping or sliding forward while seated in a wheelchair. The Heelbo ICU 911 Blazer Sleeved Jacket is also intended to limit the patient's movement while lying in bed to prevent the patient from falling out of bed or climbing over the side rails.
Device Story
Jacket-style safety vest; used in ICU, critical care, and healthcare facilities. Provides postural support for patients in wheelchairs/geri-chairs to prevent slumping/sliding; limits patient movement in bed/gurney to prevent falls or climbing over side rails. Features short sleeves, Velcro fasteners, and back zipper for secure fit/quick release. Includes rear zippers for access to monitoring leads/IV lines and deep neckline for tracheal tubes/arterial catheters. Secured to bed/wheelchair via straps; optional knotless quick-disconnect system available. Caregiver-operated. Benefits include patient safety and fall prevention.
Clinical Evidence
No clinical data. Substantial equivalence based on identical design, materials, and manufacturing process to the predicate device, supported by a history of safe use of materials in the garment industry.
Technological Characteristics
Jacket-style restraint; materials: poly/cotton blend or polyester mesh. Features: Velcro fasteners, back zippers for line access, deep neckline, and strap-based securement system. Available with optional knotless quick-disconnect mechanism. Machine washable. Five sizes available, color-coded.
Indications for Use
Indicated for patients in ICU, critical care, or other healthcare settings requiring postural support while seated in a wheelchair/geri-chair or movement limitation while in bed/gurney to prevent falls or climbing over side rails.
Regulatory Classification
Identification
A protective restraint is a device, including but not limited to a wristlet, anklet, vest, mitt, straight jacket, body/limb holder, or other type of strap, that is intended for medical purposes and that limits the patient's movements to the extent necessary for treatment, examination, or protection of the patient or others.
Predicate Devices
Heelbo ICU 911 Blazer Sleeved Jacket
Related Devices
K963243 — HEELBO BLAZER SLEEVED JACKET · Heelbo, Inc. · Oct 1, 1996
K963099 — HEELBO PULLOVER PONCHO AND PULLOVER PONCHO WITH POCKET · Heelbo, Inc. · Nov 1, 1996
K963294 — HEELBO WRAP AROUND VEST · Heelbo, Inc. · Oct 11, 1996
K963471 — SUPER SECURITY RESTRAINT · Deroyal Industries, Inc. · Nov 14, 1996
K963430 — PROTECTIVE RESTRAINT (VEST RESTRAINT) · Kenad SG Medical, Inc. · Nov 22, 1996
Submission Summary (Full Text)
{0}
K963237
Heelbo, Inc.
1134 N. Homan Ave.
Chicago, IL 60651
312/489-7711
Telex RCA 297-248
800/323-5444
Fax 312/489-7744
OCT - 9 1996
Heelbo, Inc.
ICU 911 Blazer Sleeved Jacket
## Safety and Effectiveness Summary
### 1. Submitter's name, Address and Contact Person
| Submitter | Contact Person |
| --- | --- |
| Heelbo, Inc.
1134 N. Homan Ave.
Chicago, IL 60651 | Joseph S. Tokarz; Manager, Regulatory Affairs
Hollister Incorporated
2000 Hollister Drive
Libertyville, IL 60048
Ph: (847)680-2849, Fax: (847)918-3860 |
Date Summary Prepared - August 14, 1996
### 2. Name of Device:
Heelbo ICU 911 Blazer Sleeved Jacket
### 3. Name of Predicate Device(s)
Heelbo ICU 911 Blazer Sleeved Jacket
### 4. Description of Device
The Heelbo ICU 911 Blazer Sleeved Jacket is a jacket-style safety vest. The Heelbo ICU 911 Blazer Sleeved Jacket is intended for use in the ICU (Intensive Care Unit), critical care situations as well as other areas of the health care facility. The jacket is intended to help support and help prevent a patient from slumping or sliding forward while seated in a wheelchair or geri-chair. The Heelbo ICU 911 Blazer Sleeved Jacket is also intended to limit the patient’s movement while lying on a bed or gurney to prevent the patient from falling out of bed or climbing over the side rails.
The jacket has short sleeves and straps on each side of the vest that can be tied together to ensure a comfortable fit. The jacket is constructed with Velcro® fasteners and a zipper in the back to ensure a secure fit as well as allowing for quick and easy release. Additional zippers are located on the back of the vest along each shoulder blade area of the device. These zippers are provided to allow the caregiver quick and easy access to vital monitoring support leads and IV lines. The jacket also has been designed with an extra deep neckline to accommodate tracheal tubes and arterial catheters.
Page 22
{1}
Heelbo, Inc.
1134 N. Homan Ave. Chicago, IL 60651
312/489-7711
Telex RCA 297-248
800/323-5444
Fax 312/489-7744
Heelbo, Inc.
ICU 911 Blazer Sleeved Jacket
The jacket is secured to the bed or wheelchair with two straps that are attached to the bottom of the vest. Optional loops sewn to the shoulder area of the vest are provided in the event extra support is needed.
The ICU 911 Blazer Sleeved Jacket is available with a knotless system (quick disconnect option). This option allows the caregiver to quickly and easily disconnect the restraint from the chair or bed frame by eliminating time consuming untying of knots (a picture of the loop accessory is attached to this section).
The ICU 911 Blazer Sleeved Jacket is available in a poly/cotton blend or a polyester mesh material. Five sizes accommodate a wide range of patients. The ICU 911 Blazer Sleeved Jacket is made of durable machine washable materials and is color coded for easy size identification.
The following chart shows product availability:
ICU 911 Blazer Sleeved Jacket is Available in the following Sizes and Configurations
| Series | Material | Size of Vest | Color |
| --- | --- | --- | --- |
| 9417
9417K | Poly/Cotton blend | x-small | White |
| | | small | Yellow |
| | | medium | Blue |
| | | large | Green |
| | | x-large | Beige |
| 9417B
9417BK | Polyester Mesh material | x-small | White bias on white breezewear |
| | | small | Yellow bias on white breezewear |
| | | medium | Blue bias on white breezewear |
| | | large | Green bias on white breezewear |
| | | x-large | Beige bias on white breezewear |
5. Statement of Intended Use
The Heelbo ICU 911 Blazer Sleeved Jacket is intended to help support and help prevent a patient from slumping or sliding forward while seated in a wheelchair. The Heelbo ICU 911 Blazer Sleeved Jacket is also intended to limit the patient's movement while lying in bed to prevent the patient from falling out of bed or climbing over the side rails.
Page 23
{2}
Heelbo, Inc.
1134 N. Homan Ave. Chicago, IL 60651
312/489-7711
Telex RCA 297-248
800/323-5444
Fax 312/489-7744
Heelbo, Inc.
ICU 911 Blazer Sleeved Jacket
## 6. Statement of Technological Characteristics of the Device
The jacket has short sleeves and straps on each side of the vest that can be tied together to ensure a comfortable fit. The jacket is constructed with Velcro® fasteners and a zipper in the back to ensure a secure fit as well as allowing for quick and easy release. Additional zippers are located on the back of the vest along each shoulder blade area of the device. These zippers are provided to allow the caregiver quick and easy access to vital monitoring support leads and IV lines. The jacket also has been designed with an extra deep neckline to accommodate tracheal tubes and arterial catheters.
The jacket is secured to the bed or wheelchair with two straps that are attached to the bottom of the vest. Optional loops sewn to the shoulder area of the vest are provided in the event extra support is needed.
The ICU 911 Blazer Sleeved Jacket is available with a knotless system (quick disconnect option). This option allows the caregiver to quickly and easily disconnect the restraint from the chair or bed frame by eliminating time consuming untying of knots (a picture of the loop accessory is attached to this section).
The subject devices are identical in intended use, design, materials, manufacturing process, physical and mechanical specifications and issues of safety and effectiveness to the devices prior to the submission of this notification. The only difference is that the product labeling has been revised to comply with the Agency’s labeling requirements set forth in the draft “Guidance on the Content of Premarket Notification [501(k)] Submissions for Protective Restraints” dated December 1995.
## 7. Biocompatibility
The subject devices are identical in component materials to the predicate devices. The suppliers of the materials use in the fabrication of these devices have stated that there is a history of safe use of their materials in the clothing and garment industry. In addition, Heelbo, Inc., is not aware of any reports or complaints of skin irritation associated with these materials.
## 8. Conclusion
Based upon the information presented above it is concluded that the proposed Heelbo ICU 911 Blazer Sleeved Jacket is safe and effective for its intended use and is substantially equivalent to the predicate device.
Page 24
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.