K962963 · Hollister, Inc. · FMQ · Oct 24, 1996 · General Hospital
Device Facts
Record ID
K962963
Device Name
CHECKMATE ANKLE RESTRAINT SYSTEM
Applicant
Hollister, Inc.
Product Code
FMQ · General Hospital
Decision Date
Oct 24, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.6760
Device Class
Class 1
Indications for Use
The Checkmate Ankle Restraint System is intended to be used in situations requiring patient control while the patient is lying on a bed or gurney. The Checkmate Ankle Restraint System is intended to secure the patient’s ankles by keeping them in a fixed position.
Device Story
The Checkmate Ankle Restraint System is a physical restraint device used in clinical settings to secure a patient's ankles to a bed or gurney. It consists of two quilted ankle cuffs made of polyester and polyurethane foam laminate, connected by a 33-inch woven polypropylene security strap. The cuffs are secured around the patient's ankles using Velcro hook-and-loop fasteners and a Double D-Ring closure system. Webbed straps at the ends of the security strap anchor the system to the bed frame. The device is operated by healthcare staff to maintain patient positioning and control.
Clinical Evidence
No clinical data. Biocompatibility assessment based on history of safe use of materials in the clothing and garment industry and lack of reported skin irritation.
Technological Characteristics
Materials: Woven polypropylene fabric (security strap), polyester and polyurethane foam laminate (cuffs). Closure: Velcro hook-and-loop and Double D-Ring. Dimensions: 4 inches wide, 33 inches long security strap. Mechanical restraint system; no energy source or software.
Indications for Use
Indicated for patients requiring physical restraint of the ankles while lying on a bed or gurney to maintain a fixed position for patient control.
Regulatory Classification
Identification
A protective restraint is a device, including but not limited to a wristlet, anklet, vest, mitt, straight jacket, body/limb holder, or other type of strap, that is intended for medical purposes and that limits the patient's movements to the extent necessary for treatment, examination, or protection of the patient or others.
K963416 — ANKLE RESTRAINT SYSTEM · Morrison Medical Products · Nov 6, 1996
K963108 — HEELBO QUILTED TORSO RESTRAINT · Hollister, Inc. · Oct 9, 1996
K962429 — SAFETY VEST · Johnson & Johnson Professionals, Inc. · Sep 18, 1996
K962626 — PATIENT PROTECTIVE LIMB · Kenad SG Medical, Inc. · Oct 2, 1996
K963464 — RESTRAINT NET · Deroyal Industries, Inc. · Nov 12, 1996
Submission Summary (Full Text)
{0}
K962963
Heelbo, Inc.
1134 N. Homan Ave. Telex RCA 297-248
Chicago, IL 60651 800/323-5444
312/489-7711 Fax 312/489-7744
OCT 24 1996
Heelbo, Inc.
Checkmate Ankle Restraint System
# Safety and Effectiveness Summary
## 1. Submitter's name, Address and Contact Person
| Submitter | Contact Person |
| --- | --- |
| Heelbo, Inc. | Joseph S. Tokarz, Manager, Regulatory Affairs |
| 1134 N. Homan Ave. | Hollister Incorporated |
| Chicago, IL | 2000 Hollister Drive
Libertyville, IL 60048 |
| | Ph: (847)680-2849, Fax: (847)918-3860 |
Date Summary Prepared - July 25, 1996
## 2. Name of Device:
Checkmate Ankle Restraint System
## 3. Name of Predicate Device(s)
Checkmate Ankle Restraint System
## 4. Description of Device
The Checkmate Ankle Restraint System is designed for situations requiring patient control. The Checkmate System is a restraint system that secures the patient’s ankles in a fixed position. It consists of two individual quilted ankle restraints that are permanently attached at a specific distance apart from each other to a long security strap. The security strap is constructed from a woven polypropylene fabric that is 4 inches wide and 33 inches long. The webbed straps attached to both ends of the security strap secure the ankle restraint system to a bed or gurney. The individual ankle restraints are made of a soft polyester and polyurethane foam laminate that forms a cuff that closes around the patient’s ankle. The ankle restraint is held securely closed with Velcro® (hook and loop) and a Double D-Ring closure with strap.
## 5. Statement of Intended Use
The Checkmate Ankle Restraint System is intended to be used in situations requiring patient control while the patient is lying on a bed or gurney. The Checkmate Ankle Restraint System is intended to secure the patient’s ankles by keeping them in a fixed position.
Page 18
{1}
Heelbo, Inc.
1134 N. Homan Ave. Chicago, IL 60651
312/489-7711
Telex RCA 297-248
800/323-5444
Fax 312/489-7744
Heelbo, Inc.
Checkmate Ankle Restraint System
## 6. Statement of Technological Characteristics of the Device
The Checkmate Ankle Restraint System is designed for situations requiring patient control. The Checkmate System is a restraint system that secures the patient’s ankles in a fixed position. It consists of two individual quilted ankle restraints that are permanently attached at a specific distance apart from each other to a long security strap. The security strap is constructed from a woven polypropylene fabric that is 4 inches wide and 33 inches long. The webbed straps attached to both ends of the security strap secure the ankle restraint system to a bed or gurney. The individual ankle restraints are made of a soft polyester and polyurethane foam laminate that forms a cuff that closes around the patient’s ankle. The ankle restraint is held securely closed with Velcro® (hook and loop) and a Double D-Ring closure with strap.
The subject devices are identical in intended use, design, materials, manufacturing process, physical and mechanical specifications and issues of safety and effectiveness to the devices prior to the submission of this notification. The only difference is that the product labeling has been revised to comply with the Agency’s labeling requirements set forth in the draft “Guidance on the Content of Premarket Notification [501(k)] Submissions for Protective Restraints” dated December 1995.
## 7. Biocompatibility Assessment
The subject devices are identical in component materials to the predicate devices. The suppliers of the materials use in the fabrication of these devices have stated that there is a history of safe use of their materials in the clothing and garment industry. In addition, Heelbo, Inc., is not aware of any reports or complaints of skin irritation associated with these materials.
## 8. Conclusion
Based upon the information presented above it is concluded that the proposed Checkmate Ankle Restraint System is safe and effective for its intended use and is substantially equivalent to the predicate device.
Page 19
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.