MODEL 1200 ABMULATORY INFUSION PUMP

K961263 · Patient Solutions, Inc. · FRN · Aug 23, 1996 · General Hospital

Device Facts

Record IDK961263
Device NameMODEL 1200 ABMULATORY INFUSION PUMP
ApplicantPatient Solutions, Inc.
Product CodeFRN · General Hospital
Decision DateAug 23, 1996
DecisionST
Submission TypeTraditional
Regulation21 CFR 880.5725
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The PSI Model 1200 ambulatory infusion pump is a multifunction pump designed to manage a wide variety of intravenous fluid profiles.

Device Story

Model 1200 ambulatory infusion pump; portable device for hospital, clinic, or home care use. Administers intravenous fluids via dedicated disposables and accessories. Operated by clinicians or patients to manage various fluid profiles. Provides controlled fluid delivery; supports clinical decision-making by ensuring accurate infusion therapy. Benefits patient through mobility and consistent fluid management.

Technological Characteristics

Portable ambulatory infusion pump; uses dedicated disposables and accessories. Design, materials, and components similar to predicate devices.

Indications for Use

Indicated for patients requiring intravenous fluid therapy managed by an ambulatory infusion pump in hospital, clinic, or home care settings.

Regulatory Classification

Identification

An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} AUG 23 1996 K941263 # APPENDIX F Patient Solutions Inc. # MODEL 1200 510(k) Summary 261 {1} 13220 Evening Creek Dr. So. Suite #114 San Diego, CA 92128 619-679-3840 FAX 619-679-3844 # 510(k) SUMMARY Submitter's Name: Patient Solutions Inc.(PSI) Address: 13220 Evening Creek Dr. So. Suite #114 San Diego, California 92128 Phone: (619) 679-3840 Contact: Tom Kane Date of Summary: April 1, 1996 Name of Device: Model 1200 Ambulatory Infusion Pump Legally Marketed Device to Which Substantially Equivalency Is Claimed: Sabratek 6060 Homerun and Abbott Aim ## Description of Device: The PSI Model 1200 is a small portable ambulatory infusion pump intended for hospital, clinic and home care use. It uses dedicated disposables and related accessories. ## Intended Use: The PSI Model 1200 ambulatory infusion pump is a multifunction pump designed to manage a wide variety of intravenous fluid profiles. ## Technological Characteristics The PSI, Sabratek and Abbott ambulatory infusion pumps all have the same general design and incorporate similar technologies, materials, and components. The primary function of the PSI Model 1200 is the same as the Sabratek 6060 and Abbott Aim, to administer fluids to a patient. The technological characteristics of the devices are the same and raise no new questions of safety and effectiveness. PSI concludes that the PSI Model 1200 is substantially equivalent to the Sabratek 6060 and Abbott Aim in providing infusion fluid therapy for the same clinical purposes that require the use of an ambulatory infusion pump. 262
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...