SOLO PICC/MIDLINE CATHETER KIT MODELS 71924, 71908
Device Facts
| Record ID | K961155 |
|---|---|
| Device Name | SOLO PICC/MIDLINE CATHETER KIT MODELS 71924, 71908 |
| Applicant | Douglas Medical Products Corp. |
| Product Code | LJS · General Hospital |
| Decision Date | Jun 18, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 880.5970 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The SoloPak Peripheral Intravenous Catheter Insertion Kits are intended to be used for the placement of a peripheral catheter. The SoloPak Peripheral Intravenous Catheter Insertion Kits include a single lumen catheter, introducer, and the necessary accessories to perform the placement.
Device Story
Procedural tray for peripheral intravenous catheter placement; contains single lumen catheter, introducer, and accessories. Used by clinicians in clinical settings to facilitate vascular access. Device components and materials equivalent to predicate procedural trays. Sterilized to 10^-6 sterility assurance level per AAMI guidelines.
Clinical Evidence
Bench testing only; no clinical data provided. Equivalence established via comparison of materials, components, and manufacturing processes to predicate devices.
Technological Characteristics
Procedural tray containing single lumen catheter, introducer, and accessories. Sterilization: AAMI guidelines, 10^-6 sterility assurance level.
Indications for Use
Indicated for use in the placement of a peripheral intravenous catheter in patients requiring peripheral vascular access.
Regulatory Classification
Identification
A percutaneous, implanted, long-term intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings, such as luer hubs, and accessories that facilitate the placement of the device. The device allows for repeated access to the vascular system for long-term use of 30 days or more, and it is intended for administration of fluids, medications, and nutrients; the sampling of blood; and monitoring blood pressure and temperature. The device may be constructed of metal, rubber, plastic, composite materials, or any combination of these materials and may be of single or multiple lumen design.
Special Controls
*Classification.* Class II (special controls) Guidance Document: “Guidance on Premarket Notification [510(k)] Submission for Short-Term and Long-Term Intravascular Catheters.”
Predicate Devices
- Clinicath™ Procedural Tray (K932211)
- Per-Q-Cath Tray (K83145)
Related Devices
- K962849 — CATHETER INSERTION TRAY · Medcare Medical Group, Inc. · Oct 7, 1996
- K951620 — MIDMARK MIDLINE CATHETER · Menlo Care, Inc. · Apr 4, 1996
- K070865 — EXPANDING VASCULAR SHEATH · Applied Medical · Oct 23, 2007
- K063658 — INTRAVASCULAR INTRODUCER SYSTEM · Applied Medical Resources Corp. · Sep 12, 2007
- K163452 — PICC Maximal Barrier Nursing Kit · Navilyst Medical, Inc. · Feb 3, 2017