BD PHASEAL CLOSED SYSTEM TRANSFER DEVICE - INJECTOR

K140591 · Becton, Dickinson & CO · ONB · May 14, 2014 · General Hospital

Device Facts

Record IDK140591
Device NameBD PHASEAL CLOSED SYSTEM TRANSFER DEVICE - INJECTOR
ApplicantBecton, Dickinson & CO
Product CodeONB · General Hospital
Decision DateMay 14, 2014
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 880.5440
Device ClassClass 2

Indications for Use

The PhaSeal system is an airtight and leakproof closed system drug transfer device (CSTD) that mechanically prohibits the transfer of environmental contaminants into the system and the escape of drug or vapor concentrations outside the system, thereby minimizing individual and environmental exposure to drug vapor, aerosols and spills. The PhaSeal system also prevents microbial ingress.

Device Story

BD PhaSeal Injector is a sterile, single-use luer device adaptor component of the PhaSeal CSTD system. It facilitates dry, leak-proof liquid transfer between syringes/IV tubing and drug containers sealed with PhaSeal Protectors or Connectors. Operation involves a bayonet fitting and a single lumen cannula that perforates double self-sealing elastomeric membranes. This mechanical design prevents environmental contaminant ingress and hazardous drug/vapor escape, protecting clinicians from aerosols and spills. Used in clinical settings during drug reconstitution, administration, and disposal. Benefits include reduced occupational exposure to hazardous drugs and minimized microbial contamination risk.

Clinical Evidence

Bench testing only. No clinical data provided. Design verification included biocompatibility testing per ISO 10993, dye leak testing for membrane integrity, and fragmentation testing, all demonstrating performance equivalent to the predicate device.

Technological Characteristics

Sterile, single-use closed system drug transfer device. Components utilize bayonet fittings and double self-sealing thermoplastic elastomer (TPE) membranes. Subject device membrane includes silicone lubricant. Mechanical operation via single lumen cannula. No electronic or software components.

Indications for Use

Indicated for use as a closed system drug transfer device (CSTD) to minimize exposure to hazardous drugs and prevent microbial ingress during reconstitution, administration, and disposal processes. Intended for prescription use.

Regulatory Classification

Identification

An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.

Special Controls

*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Date Prepared: 4 March 2014 Submitted By: John Roberts Regulatory Affairs Specialist BD Medical - Medical Surgical Systems l Becton Drive Franklin Lakes, NJ 07417 Tel: 201 847 5473; Fax: 201 847 5307 #### 2. Device Name: l. Trade Name: Common Name: Classification: BD PhaSeal Closed System Transfer Device - Injector Closed antineoplastic & hazardous drug reconstitution & transfer system Classification Name: Intravascular administration set Class II. 21 C.F.R. § 880.5440 #### 3. Predicate Device BD PhaSeal® Connector, Injector, Protector - K123213 #### 4. Device Description: The PhaSeal® System is a sterile single-use closed system drug transfer device. The closed transfer of liquid takes place through a double membrane utilizing self-sealing elastomeric membranes, tightly fitted together through a bayonet fitting on all PhaSeal components. A single lumen cannula perforates the double membranes for the transfer of liguid. When the cannula is retracted the membranes seal off the transfer of environmental contaminants into the system and/or escape of drug or vapor concentrations outside the system, thereby minimizing the individual and environmental exposure to drug vapor, aerosols and spills and also minimizing the risk of microbial contamination. The PhaSeal Injector is one component of the PhaSeal system. It is a luer device adaptor that may be fitted to a syringe or IV tubing. It is used to gain dry and leak-proof access to a drug container or administration device which has been sealed with a PhaSeal Protector or Connector. Liquid transfer takes place through tightly fitting elastomeric double membranes to minimize exposure to potentially hazardous drug aerosols and spills occurring during reconstitution, administration and disposal processes. #### 5. Intended Use The PhaSeal system is an airtight and leakproof closed system drug transfer device (CSTD) that mechanically prohibits the transfer of environmental contaminants into the system and the escape of drug or vapor concentrations outside the system, thereby minimizing individual and environmental exposure to drug vapor, aerosols and spills. The PhaSeal system also prevents microbial ingress. {1}------------------------------------------------ ### 6. Technological Characteristics The technological characteristics referenced in Table 1: Technological Characteristics below have been modified from the predicate device. The results of design verification demonstrate that these characteristics are substantially equivalent to the predicate device. All other the technological characteristics of the subject device are identical to those of the predicate devices. # Table 1: Technological Characteristics | Subject | Predicate (K123213) | Modified Device<br>(N30C, N35, N35C) | Equiv. | |-------------------|-------------------------------|--------------------------------------|--------| | Injector membrane | Thermoplastic Elastomer (TPE) | TPE w/ silicone lubricant | Yes | ### 7. Performance Design Verification tests were performed based on the risk analysis performed, and the results of these tests demonstrate that the BD PhaSeal Closed System Transfer Device -Injector (N30C, N35, N35C) performed in an equivalent manner to the predicate device and is safe and effective when used as intended. Design Verification testing included the following: ## Table 2: Design Verification Testing | Characteristic | Test Performed | Result | |------------------------|--------------------|-------------------------| | Biocompatibility | Per ISO 10993 | Per ISO 10993 | | Membrane Leakage | Dye Leak Test | Equivalent to Predicate | | Membrane Fragmentation | Fragmentation Test | Equivalent to Predicate | ### 8. Conclusion Based on comparison to the predicate device and the results of design verification testing, the modified BD PhaSeal® Closed System Drug Transfer Device - Injector (N30C, N35, N35C) is as safe, as effective, and performs as well as the legally marketed predicate device. {2}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three wings, representing the department's mission to protect the health of all Americans and provide essential human services. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle symbol. --- Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G60 Silver Spring, MD 20993-0002 May 14, 2014 Becton, Dickinson and Company Mr. John Roberts Regulatory Affairs Specialist 1 Becton Drive MC237 FRANKLIN LAKES, NJ 07417 Re: K140591 Trade/Device Name: BD PhaSeal Closed System Transfer Device - Injector Regulation Number: 21 CFR 880.5440 Regulation Name: Intravascular administration set Regulatory Class: II . Product Code: ONB Dated: April 17, 2014 Received: April 21, 2014 Dear Mr. Roberts, We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, Mary Si Bunner -S Erin I. Keith, M.S. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ ### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration # Indications for Use 510(k) Number (if known) K140591 Device Name BD PhaSeal Closed System Transfer Device - Injector Indications for Use (Describe) The PhaSeal system is an airtight and leakproof closed system drug (CSTD) that mechanically prohibits the transfer of environmental contaminants into the system and the escape of drug or vapor concentrations outside the system, thereby minimizing individual and environmental exposure to drug vapor, aerosols and spills. The PhaSeal system also prevents microbial ingress. Type of Use (Select one or both, as applicable) 2 Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) # PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED. FOR FOR FOR FOR FOR FOR FOR FOR A BOOK FOR FOR FOR FOR FOR Concurrence of Center for Devices and Radiological Health (CDRH) (Signature) Image /page/4/Picture/13 description: The image shows the logo for the Food and Drug Administration (FDA). The letters "FDA" are displayed in a bold, sans-serif font. The logo is simple and recognizable, and it is often used on products that have been approved by the FDA. The logo is a symbol of safety and quality. Digitally signed by Richard C. Chapman Date: 2014.05.14 07:44:46 -04'00' This section applies only to requirements of the Paperwork Reduction Act of 1995. ### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW." The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." Form Approved: OMB No. 0910-0120 Expiration Date: January 31, 2017 See PRA Statement below.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...